Literature DB >> 7663327

Dynamic mechanical spectroscopy of the cornea for measurement of its viscoelastic properties in vitro.

F Soergel1, B Jean, T Seiler, T Bende, S Mücke, W Pechhold, L Pels.   

Abstract

Cylindric samples (3 mm in diameter) of explanted human corneas were biomechanically characterized in the frequency range from 0.1 mHz to 100 Hz with a specially modified viscoelasticity spectrometer. Such spectra of the shear compliance J (the reciprocal value of the shear modulus G) were measured as a function of corneal hydration and temperature. Variation of the hydration from 0.20- to 1.00-mm sample thickness (5-fold) changed the shear compliance 600-fold. Such a strong effect means that the shear-compliance spectra are highly sensitive to changes in the biomechanical properties of the cornea. This is demonstrated by three examples. A myopic cornea (-3D) was significantly softer (by a factor of 7 at lower frequencies and a factor of 4 at higher frequencies) than an emmetropic cornea. An increasing post mortem interval decreased the shear-compliance values (stiffening) obtained at higher frequencies (by a factor of 0.7 per day), whereas the values obtained at lower frequencies were reproduced. The biomechanics of thermal coagulation were studied in detail. The temperature was increased step by step, and at 48 degrees C a first irreversible decrease in the compliance was recorded at lower frequencies (0.8-fold). A further stiffening by a factor of 1/6 at lower frequencies and 1/5 at higher frequencies ended at 64 degrees C with a minimum in the compliance. To provide a new diagnostic tool, the biomechanical spectra of the cornea have to be measured in vivo. Equipment suitable for the megahertz range has been developed.(ABSTRACT TRUNCATED AT 250 WORDS)

Entities:  

Mesh:

Year:  1995        PMID: 7663327

Source DB:  PubMed          Journal:  Ger J Ophthalmol        ISSN: 0941-2921


  12 in total

1.  Corneal biomechanical data and biometric parameters measured with Scheimpflug-based devices on normal corneas.

Authors:  Gabor Nemeth; Eszter Szalai; Ziad Hassan; Agnes Lipecz; Zsuzsa Flasko; Laszlo Modis
Journal:  Int J Ophthalmol       Date:  2017-02-18       Impact factor: 1.779

2.  Dynamic testing of regional viscoelastic behavior of canine sclera.

Authors:  Joel R Palko; Xueliang Pan; Jun Liu
Journal:  Exp Eye Res       Date:  2011-10-05       Impact factor: 3.467

3.  MR elastography of the ex vivo bovine globe.

Authors:  Daniel V Litwiller; Sung J Lee; Arunark Kolipaka; Yogesh K Mariappan; Kevin J Glaser; Jose S Pulido; Richard L Ehman
Journal:  J Magn Reson Imaging       Date:  2010-07       Impact factor: 4.813

4.  In Vivo Determination of the Human Corneal Elastic Modulus Using Vibrational Optical Coherence Tomography.

Authors:  Marcos A Crespo; Hiram J Jimenez; Tanmay Deshmukh; Jose S Pulido; Ahmed Saeed Saad; Frederick H Silver; Dominick A Benedetto; Christopher J Rapuano; Zeba A Syed
Journal:  Transl Vis Sci Technol       Date:  2022-07-08       Impact factor: 3.048

5.  Oestrogen-induced changes in biomechanics in the cornea as a possible reason for keratectasia.

Authors:  Eberhard Spoerl; Viktoria Zubaty; Frederik Raiskup-Wolf; Lutz E Pillunat
Journal:  Br J Ophthalmol       Date:  2007-06-25       Impact factor: 4.638

6.  Ocular biomechanical measurements on post-keratoplasty corneas using a Scheimpflug-based noncontact device.

Authors:  Laszlo Modis; Ziad Hassan; Eszter Szalai; Zsuzsanna Flaskó; Andras Berta; Gabor Nemeth
Journal:  Int J Ophthalmol       Date:  2016-02-18       Impact factor: 1.779

7.  The influence of hydration on different mechanical moduli of the cornea.

Authors:  Theo G Seiler; Peng Shao; Beatrice E Frueh; Seok-Hyun Yun; Theo Seiler
Journal:  Graefes Arch Clin Exp Ophthalmol       Date:  2018-07-24       Impact factor: 3.117

8.  An Evaluation of Lysyl Oxidase-Derived Cross-Linking in Keratoconus by Liquid Chromatography/Mass Spectrometry.

Authors:  Anna Takaoka; Natasha Babar; Julia Hogan; MiJung Kim; Marianne O Price; Francis W Price; Stephen L Trokel; David C Paik
Journal:  Invest Ophthalmol Vis Sci       Date:  2016-01-01       Impact factor: 4.799

9.  Estimation of the Corneal Young's Modulus In Vivo Based on a Fluid-Filled Spherical-Shell Model with Scheimpflug Imaging.

Authors:  Po-Jen Shih; Chun-Ju Huang; Tzu-Han Huang; Hung-Chou Lin; Jia-Yush Yen; I-Jong Wang; Hui-Jyun Cao; Wen-Pin Shih; Chi-An Dai
Journal:  J Ophthalmol       Date:  2017-11-08       Impact factor: 1.909

10.  Biomechanical Properties of the Cornea Using a Dynamic Scheimpflug Analyzer in Healthy Eyes.

Authors:  Hun Lee; David Sung Yong Kang; Byoung Jin Ha; Jin Young Choi; Eung Kweon Kim; Kyoung Yul Seo; Tae Im Kim
Journal:  Yonsei Med J       Date:  2018-11       Impact factor: 2.759

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.