The influence of hydration on different mechanical moduli of the cornea.

Theo G Seiler1,2,3, Peng Shao4, Beatrice E Frueh5, Seok-Hyun Yun4, Theo Seiler6.   

Abstract

PURPOSE: To determine the interrelation of different elastic moduli of the cornea and to investigate their dependency on corneal hydration.
METHODS: Rabbit eyes were divided into four groups. Corneas were excised and mounted into a Barron artificial anterior chamber. Various corneal hydration steady states were achieved with different dextran T-500 concentrations in the anterior chamber, as well as on the corneal anterior surface. The treatment-solutions of each group contained either 5, 10, 15, or 20% w/w dextran. Ultrasound pachymetry was used to measure central corneal thickness. Brillouin microscopy of the central cornea determined the longitudinal bulk modulus by means of Brillouin frequency shift. Subsequently, a 5-mm-wide central strip was taken for extensiometry to measure the tangential elastic modulus.
RESULTS: The longitudinal bulk modulus was 1.2-times higher in corneas dehydrated with 20% dextran compared to those hydrated with 5% dextran. In contrast, the tangential elastic modulus increased by 4.4 times. The obtained longitudinal bulk moduli were two orders of magnitude bigger than the tangential elastic moduli. Regression analysis of longitudinal bulk modulus and tangential elastic modulus revealed a quadratic relation. The bulk modulus seemed to be independent of tension, whereas the elastic modulus was tension-dependent. Greater corneal hydration led to significantly thicker pachymetry.
CONCLUSION: Corneal biomechanics are highly dependent on the level of corneal hydration. Surprisingly, tangential elastic moduli were more sensitive to hydration changes than longitudinal bulk moduli. A quadratic relation was found between both moduli.

Entities:  

Keywords:  Biomechanics; Brillouin; Cornea; Extensiometry; Hydration; Longitudinal elastic modulus; Stress strain; Tangential elastic modulus

Mesh:

Year:  2018        PMID: 30043266     DOI: 10.1007/s00417-018-4069-7

Source DB:  PubMed          Journal:  Graefes Arch Clin Exp Ophthalmol        ISSN: 0721-832X            Impact factor:   3.117


  39 in total

1.  Depth-dependent transverse shear properties of the human corneal stroma.

Authors:  Steven J Petsche; Dimitri Chernyak; Jaime Martiz; Marc E Levenston; Peter M Pinsky
Journal:  Invest Ophthalmol Vis Sci       Date:  2012-02-21       Impact factor: 4.799

2.  Synchrotron x-ray diffraction studies of the cornea, with implications for stromal hydration.

Authors:  K M Meek; N J Fullwood; P H Cooke; G F Elliott; D M Maurice; A J Quantock; R S Wall; C R Worthington
Journal:  Biophys J       Date:  1991-08       Impact factor: 4.033

3.  Regional elastic performance of the human cornea.

Authors:  J O Hjortdal
Journal:  J Biomech       Date:  1996-07       Impact factor: 2.712

4.  Anterior and posterior corneal stroma elasticity assessed using nanoindentation.

Authors:  Janice M Dias; Noël M Ziebarth
Journal:  Exp Eye Res       Date:  2013-06-22       Impact factor: 3.467

5.  Intrastromal application of riboflavin for corneal crosslinking.

Authors:  Theo G Seiler; Isaak Fischinger; Tim Senfft; Gerald Schmidinger; Theo Seiler
Journal:  Invest Ophthalmol Vis Sci       Date:  2014-06-10       Impact factor: 4.799

6.  Biomechanical evidence of the distribution of cross-links in corneas treated with riboflavin and ultraviolet A light.

Authors:  Markus Kohlhaas; Eberhard Spoerl; Thomas Schilde; Gabriele Unger; Christine Wittig; Lutz E Pillunat
Journal:  J Cataract Refract Surg       Date:  2006-02       Impact factor: 3.351

7.  The thickness-hydration relationship of the cornea.

Authors:  B O Hedbys; S Mishima
Journal:  Exp Eye Res       Date:  1966-07       Impact factor: 3.467

8.  Impact of Hydration Media on Ex Vivo Corneal Elasticity Measurements.

Authors:  Janice Dias; Noël M Ziebarth
Journal:  Eye Contact Lens       Date:  2015-09       Impact factor: 2.018

9.  Investigating Elastic Anisotropy of the Porcine Cornea as a Function of Intraocular Pressure With Optical Coherence Elastography.

Authors:  Manmohan Singh; Jiasong Li; Zhaolong Han; Chen Wu; Salavat R Aglyamov; Michael D Twa; Kirill V Larin
Journal:  J Refract Surg       Date:  2016-08-01       Impact factor: 3.573

10.  Distribution of Young's modulus in porcine corneas after riboflavin/UVA-induced collagen cross-linking as measured by atomic force microscopy.

Authors:  Jan Seifert; Christian M Hammer; Johannes Rheinlaender; Saadettin Sel; Michael Scholz; Friedrich Paulsen; Tilman E Schäffer
Journal:  PLoS One       Date:  2014-01-31       Impact factor: 3.240

View more
  5 in total

1.  Corneal Hydration Control during Ex Vivo Experimentation Using Poloxamers.

Authors:  Keyton Clayson; Thomas Sandwisch; Yanhui Ma; Elias Pavlatos; Xueliang Pan; Jun Liu
Journal:  Curr Eye Res       Date:  2019-09-18       Impact factor: 2.424

2.  Brillouin Spectroscopy of Normal and Keratoconus Corneas.

Authors:  Theo G Seiler; Peng Shao; Amira Eltony; Theo Seiler; Seok-Hyun Yun
Journal:  Am J Ophthalmol       Date:  2019-02-15       Impact factor: 5.258

3.  Non-contact terahertz spectroscopic measurement of the intraocular pressure through corneal hydration mapping.

Authors:  Andrew Chen; Arjun Virk; Zachery Harris; Azin Abazari; Robert Honkanen; M Hassan Arbab
Journal:  Biomed Opt Express       Date:  2021-05-17       Impact factor: 3.732

Review 4.  Corneal biomechanics: Measurement and structural correlations.

Authors:  Jillian Chong; William J Dupps
Journal:  Exp Eye Res       Date:  2021-02-18       Impact factor: 3.467

5.  Effects of water drinking on corneal biomechanics: The association with intraocular pressure changes.

Authors:  Jesús Vera; Beatríz Redondo; Rubén Molina; Raimundo Jiménez
Journal:  Indian J Ophthalmol       Date:  2022-04       Impact factor: 2.969

  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.