Literature DB >> 3994020

Can we trust the direct radial artery pressure immediately following cardiopulmonary bypass?

D H Stern, J I Gerson, F B Allen, F B Parker.   

Abstract

Reversal of the usual relationship between aortic and radial artery pressure can occur in patients following cardiopulmonary bypass. Radial systolic (and often radial mean) pressures were lower, relative to aortic pressure, after cardiopulmonary bypass than before bypass in all 18 patients studied. The systolic pressure difference (aortic minus radial) was large enough to be of clinical concern (12-32 mmHg) in 13 patients. The change persisted for 10-60 min, gradually returning toward normal. The change temporally was associated with warming at the end of cardiopulmonary bypass and lowered forearm vascular resistance. Relative forearm vascular resistance (x) predicted the systolic aortic minus radial pressure difference (y) by the equation y = -0.34x + 17 for all patients (r = -0.49, P less than 0.001). The authors conclude that radial artery pressure does not accurately reflect central aortic pressure in the immediate postbypass period.

Entities:  

Mesh:

Year:  1985        PMID: 3994020     DOI: 10.1097/00000542-198505000-00002

Source DB:  PubMed          Journal:  Anesthesiology        ISSN: 0003-3022            Impact factor:   7.892


  23 in total

1.  Accuracy of four indirect methods of blood pressure measurement, with hemodynamic correlations.

Authors:  G P Gravlee; J K Brockschmidt
Journal:  J Clin Monit       Date:  1990-10

2.  Sustained effects of plasma norepinephrine levels on femoral-radial pressure gradient after cardiopulmonary bypass.

Authors:  R Nakayama; T Goto; I Kukita; R Sakata
Journal:  J Anesth       Date:  1993-01       Impact factor: 2.078

3.  Clinical evaluation of esophageal doppler cardiac output measurement during general anesthesia.

Authors:  M Ueda; S Yokota; F Nakata; S Kaseno; N Sakuraya; O Kemmotsu
Journal:  J Anesth       Date:  1989-09-01       Impact factor: 2.078

4.  Can changes in arterial pressure be used to detect changes in cardiac index during fluid challenge in patients with septic shock?

Authors:  Charalampos Pierrakos; Dimitrios Velissaris; Sabino Scolletta; Sarah Heenen; Daniel De Backer; Jean-Louis Vincent
Journal:  Intensive Care Med       Date:  2012-01-26       Impact factor: 17.440

Review 5.  Hemodynamic monitoring during liver transplantation: A state of the art review.

Authors:  Mona Rezai Rudnick; Lorenzo De Marchi; Jeffrey S Plotkin
Journal:  World J Hepatol       Date:  2015-06-08

6.  Transient stop-flow arm arterial-venous equilibrium pressure measurement: determination of precision of the technique.

Authors:  Hollmann D Aya; Andrew Rhodes; Nick Fletcher; R Michael Grounds; Maurizio Cecconi
Journal:  J Clin Monit Comput       Date:  2015-03-07       Impact factor: 2.502

7.  Computer model analysis of the radial artery pressure waveform.

Authors:  H A Schwid; L A Taylor; N T Smith
Journal:  J Clin Monit       Date:  1987-10

8.  Invasive monitoring of blood pressure: a radiant future for brachial artery as an alternative to radial artery catheterisation?

Authors:  Karim Lakhal; Vincent Robert-Edan
Journal:  J Thorac Dis       Date:  2017-12       Impact factor: 2.895

9.  Clinical assessment of the neonatal Dinamap 847 during anesthesia in neonates and infants.

Authors:  P M Cullen; J Dye; D G Hughes
Journal:  J Clin Monit       Date:  1987-10

10.  Comparison of radial and femoral arterial blood pressures in children after cardiopulmonary bypass.

Authors:  J D Gallagher; R A Moore; K W McNicholas; A B Jose
Journal:  J Clin Monit       Date:  1985-07
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.