Literature DB >> 7376846

Metal sensitivity in patients with metal-to-plastic total hip arthroplasties.

A S Carlsson, B Magnusson, H Möller.   

Abstract

Out of 134 patients patch tested after total hip replacement (metal-to-plastic) 13 were sensitive to one or two of the implanted metals. In a prospective series of 112 patients, nine were sensitive to nickel before and another three developed sensitivity to nickel or cobalt after the arthroplasty. In the retrospective as well as in the prospective series the complications could in all cases but one be explained on grounds other than allergy. The incidence of contact allergy to nickel before a planned arthroplasty was 12 per cent in females and 4 per cent in males. It is doubtful whether metal sensitivity could be induced by a total hip arthroplasty. However, in cases of a preexisting metal allergy, a certain degree of caution is recommended.

Entities:  

Mesh:

Substances:

Year:  1980        PMID: 7376846     DOI: 10.3109/17453678008990769

Source DB:  PubMed          Journal:  Acta Orthop Scand        ISSN: 0001-6470


  15 in total

1.  In vitro reactivity to implant metals demonstrates a person-dependent association with both T-cell and B-cell activation.

Authors:  Nadim James Hallab; Marco Caicedo; Rachel Epstein; Kyron McAllister; Joshua J Jacobs
Journal:  J Biomed Mater Res A       Date:  2010-02       Impact factor: 4.396

Review 2.  Allergy in Total Knee Replacement. Does It Exist?: Review Article.

Authors:  Martin Faschingbauer; Lisa Renner; Friedrich Boettner
Journal:  HSS J       Date:  2016-07-22

3.  [Metallurgical differentiation of cobalt-chromium alloys for implants].

Authors:  U Holzwarth; P Thomas; W Kachler; J Göske; A Schuh
Journal:  Orthopade       Date:  2005-10       Impact factor: 1.087

4.  [Pathological findings in tissue surrounding revised metal/metal articulations].

Authors:  W Baur; W Hönle; H-G Willert; A Schuh
Journal:  Orthopade       Date:  2005-03       Impact factor: 1.087

5.  [Implant allergies].

Authors:  P Thomas; M Thomsen
Journal:  Hautarzt       Date:  2010-03       Impact factor: 0.751

6.  Orthopaedic implant related metal toxicity in terms of human lymphocyte reactivity to metal-protein complexes produced from cobalt-base and titanium-base implant alloy degradation.

Authors:  N J Hallab; K Mikecz; C Vermes; A Skipor; J J Jacobs
Journal:  Mol Cell Biochem       Date:  2001-06       Impact factor: 3.396

7.  [Allergic potential of titanium implants].

Authors:  A Schuh; P Thomas; W Kachler; J Göske; L Wagner; U Holzwarth; R Forst
Journal:  Orthopade       Date:  2005-04       Impact factor: 1.087

8.  [Allergy to metal following osteosynthesis].

Authors:  S Hierholzer; G Hierholzer
Journal:  Unfallchirurgie       Date:  1982-12

9.  [Orthopedic surgical implants and allergies: joint statement by the implant allergy working group (AK 20) of the DGOOC (German association of orthopedics and orthopedic surgery), DKG (German contact dermatitis research group) and dgaki (German society for allergology and clinical immunology)].

Authors:  P Thomas; A Schuh; J Ring; M Thomsen
Journal:  Orthopade       Date:  2008-01       Impact factor: 1.087

10.  [Metal sensitivity in patients with joint replacement arthroplasties before and after surgery].

Authors:  C Rau; P Thomas; M Thomsen
Journal:  Orthopade       Date:  2008-02       Impact factor: 1.087

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.