[Metallurgical differentiation of cobalt-chromium alloys for implants].

U Holzwarth1, P Thomas, W Kachler, J Göske, A Schuh.   

Abstract

BACKGROUND: Cobalt Chromium alloys are used in cemented total hip or knee arthroplasty as well as in metal-on-metal bearings in total hip arthroplasty. An increasing number of publications report about (allergic) reactions to wear particles of Cobalt Chromium alloys. Reactions to nickel are more frequent in comparison to Cobalt or Chromium particles. It is well known that different kinds of Cobalt Chromium alloys contain different amounts of alloying elements; nevertheless. The aim of the current work was to compare the different Cobalt Chromium alloys according to ASTM F or ISO standards in respect to the different alloying elements.
MATERIAL AND METHODS: Co28Cr6Mo casting alloys according to ASTM F 75 or ISO 5832-4 as well as forging alloy types according to ASTM F 799 and ISO 5832 such as Co20Cr15W10Ni, Co35Ni20Cr, Fe40Co20Cr10Ni, Co20Cr20Ni, and Co28Cr6Mo were analyzed in respect to their element content of Co, Cr, Ni, Mo, Fe, W, and Mn.
RESULTS: In 1935 the Cobalt based alloy "Vitallium" Co30Cr5Mo basically used in the aircraft industry was introduced into medicine. The chemical composition of this alloy based on Cobalt showed 30 wt.% Chromium and 5 wt.% Molybdenum. The differentiation using alloy names showed no Nickel information in single alloy names.
CONCLUSION: The information given about different alloys can lead to an unprecise evaluation of histopathological findings in respect to alloys or alloying constituents. Therefore, implant manufacturers should give the exact information about the alloys used and adhere to European law, Euronorm 93/42/EWG.

Entities:  

Mesh:

Substances:

Year:  2005        PMID: 16091961     DOI: 10.1007/s00132-005-0849-y

Source DB:  PubMed          Journal:  Orthopade        ISSN: 0085-4530            Impact factor:   1.087


  29 in total

1.  Urticaria after insertion of Smith-Petersen Vitallium nail.

Authors:  A W McKenzie; C V Aitken; R Ridsdill-Smith
Journal:  Br Med J       Date:  1967-10-07

2.  Occupational asthma from cobalt sensitivity in workers exposed to hard metal dust.

Authors:  T Shirakawa; Y Kusaka; N Fujimura; S Goto; M Kato; S Heki; K Morimoto
Journal:  Chest       Date:  1989-01       Impact factor: 9.410

3.  Immunotoxicity of medical devices. Symposium overview.

Authors:  K Rodgers; P Klykken; J Jacobs; C Frondoza; V Tomazic; J Zelikoff
Journal:  Fundam Appl Toxicol       Date:  1997-03

4.  Cutaneous metal sensitivity in patients with orthopaedic injuries.

Authors:  M F Swiontkowski; J Agel; J Schwappach; P McNair; M Welch
Journal:  J Orthop Trauma       Date:  2001-02       Impact factor: 2.512

5.  Prevalence of contact allergy by sex, race and age.

Authors:  C L Goh
Journal:  Contact Dermatitis       Date:  1986-04       Impact factor: 6.600

Review 6.  Distribution of cobalt chromium wear and corrosion products and biologic reactions.

Authors:  K Merritt; S A Brown
Journal:  Clin Orthop Relat Res       Date:  1996-08       Impact factor: 4.176

7.  Metal sensitivity in patients with joint replacement arthroplasties.

Authors:  M K Benson; P G Goodwin; J Brostoff
Journal:  Br Med J       Date:  1975-11-15

8.  An unusual reaction in muscle in association with Vitallium plate: a report of possible metal hypersensitivity.

Authors:  D S Halpin
Journal:  J Bone Joint Surg Br       Date:  1975-11

Review 9.  [Allergic reactions to implant materials].

Authors:  P Thomas
Journal:  Orthopade       Date:  2003-01       Impact factor: 1.087

10.  Cutaneous complications of orthopedic implants. A two-year prospective study.

Authors:  R Kubba; J S Taylor; K E Marks
Journal:  Arch Dermatol       Date:  1981-09
View more
  9 in total

1.  A case series of cementless revision total knee arthroplasty in patients with benzoyl peroxide allergy.

Authors:  Frank S Fröschen; Nadine Gravius; Jan-Frederic Lau; Thomas Martin Randau; Eva Kaup; Max J Friedrich; Sascha Gravius
Journal:  Int Orthop       Date:  2018-12-11       Impact factor: 3.075

2.  [Implant allergies].

Authors:  P Thomas; M Thomsen
Journal:  Hautarzt       Date:  2010-03       Impact factor: 0.751

3.  [Orthopedic surgical implants and allergies: joint statement by the implant allergy working group (AK 20) of the DGOOC (German association of orthopedics and orthopedic surgery), DKG (German contact dermatitis research group) and dgaki (German society for allergology and clinical immunology)].

Authors:  P Thomas; A Schuh; J Ring; M Thomsen
Journal:  Orthopade       Date:  2008-01       Impact factor: 1.087

4.  [Recurrent effusion and granulomatous synovitis following total knee arthroplasty in association with latex allergy].

Authors:  A Schuh; P Thomas; W Hönle; T Schmickal
Journal:  Orthopade       Date:  2008-02       Impact factor: 1.087

Review 5.  Effects of metal-on-metal wear on the host immune system and infection in hip arthroplasty.

Authors:  Anton H Hosman; Henny C van der Mei; Sjoerd K Bulstra; Henk J Busscher; Danielle Neut
Journal:  Acta Orthop       Date:  2010-10       Impact factor: 3.717

Review 6.  Clinical and diagnostic challenges of metal implant allergy using the example of orthopaedic surgical implants: Part 15 of the Series Molecular Allergology.

Authors:  Peter Thomas
Journal:  Allergo J Int       Date:  2014-09-29

Review 7.  Implant allergy.

Authors:  P Thomas; B Summer
Journal:  Allergol Select       Date:  2017-08-04

8.  [Orthopedic surgical implants and allergies. Joint statement by the Implant Allergy Working Group (AK 20) of the DGOOC (German Association of Orthopedics and Orthopedic Surgery), DKG (German Contact Dermatitis Research Group) and DGAKI (German Society for Allergology and Clinical Immunology)].

Authors:  P Thomas; A Schuh; J Ring; M Thomsen
Journal:  Hautarzt       Date:  2008-03       Impact factor: 1.198

9.  Solochrome cyanine: A histological stain for cobalt-chromium wear particles in metal-on-metal periprosthetic tissues.

Authors:  I Papadimitriou-Olivgeri; J M Brown; A F R Kilpatrick; H S Gill; N A Athanasou
Journal:  J Mater Sci Mater Med       Date:  2019-09-06       Impact factor: 3.896

  9 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.