Literature DB >> 11678594

Orthopaedic implant related metal toxicity in terms of human lymphocyte reactivity to metal-protein complexes produced from cobalt-base and titanium-base implant alloy degradation.

N J Hallab1, K Mikecz, C Vermes, A Skipor, J J Jacobs.   

Abstract

Metal toxicity from sources such as orthopaedic implants was investigated in terms of immune system hyper-reactivity to metal implant alloy degradation products. Lymphocyte response to serum protein complexed with metal from implant alloy degradation was investigated in this in vitro study using primary human lymphocytes from healthy volunteers (n = 10). Cobalt chromium molybdenum alloy (Co-Cr-Mo, ASTM F-75) and titanium alloy (Ti-6Al-4V, ASTM F-136) beads (70 microm) were incubated in agitated human serum at 37 degrees Celsius to simulate naturally occurring metal implant alloy degradation processes. Particulate free serum samples, which were incubated with metal, were then separated into molecular weight based fractions. The amounts of soluble Cr and Ti within each serum fraction were measured and correlated with lymphocyte proliferation response to the individual serum fractions. Lymphocytes from each subject were cultured with 11 autologous molecular weight based serum fractions either with or without added metal. Two molecular weight ranges of human serum proteins were associated with the binding of Cr and Ti from Co-Cr-Mo and Ti implant alloy degradation (at < 30 and 180-330 kDa). High molecular weight serum proteins (approximately 180 kDa) demonstrated greater lymphocyte reactivity when complexed with metal released from Co-Cr-Mo alloy and Ti alloy than with low (5-30 kDa) and midrange (30-77 kDa) serum proteins. When the amount of lymphocyte stimulation was normalized to both the moles of metal and the moles of protein within each fraction (Metal-Protein Complex Reactivity Index, MPCRI), Cr from Co-Cr-Mo alloy degradation demonstrated approximately 10 fold greater reactivity than Ti in the higher molecular weight serum proteins (approximately 180-250 kDa). This in vitro study demonstrated a lymphocyte proliferative response to both Co-Cr-Mo and Ti alloy metalloprotein degradation products. This response was greatest when the metals were complexed with high molecular weight proteins, and with metal-protein complexes formed from Co-Cr-Mo alloy degradation.

Entities:  

Mesh:

Substances:

Year:  2001        PMID: 11678594

Source DB:  PubMed          Journal:  Mol Cell Biochem        ISSN: 0300-8177            Impact factor:   3.396


  49 in total

1.  Generalized eczema from vitallium osteosynthesis material.

Authors:  C Merle; M Vigan; D Devred; P Girardin; B Adessi; R Laurent
Journal:  Contact Dermatitis       Date:  1992-10       Impact factor: 6.600

2.  Severe eczema of the hands due to an orthopaedic plate made of Vitallium.

Authors:  R H Thomas; M Rademaker; N J Goddard; D D Munro
Journal:  Br Med J (Clin Res Ed)       Date:  1987-01-10

Review 3.  Systemic effects of implanted prostheses made of cobalt-chromium alloys.

Authors:  R Michel; M Nolte; M Reich; F Löer
Journal:  Arch Orthop Trauma Surg       Date:  1991       Impact factor: 3.067

4.  An unusual reaction in muscle in association with Vitallium plate: a report of possible metal hypersensitivity.

Authors:  D S Halpin
Journal:  J Bone Joint Surg Br       Date:  1975-11

5.  Mercuric-chloride-induced autoimmunity in mice involves up-regulated presentation by spleen cells of altered and unaltered nucleolar self antigen.

Authors:  M Kubicka-Muranyi; P Griem; B Lübben; N Rottmann; R Lührmann; E Gleichmann
Journal:  Int Arch Allergy Immunol       Date:  1995-09       Impact factor: 2.749

6.  Murine systemic autoimmune disease induced by mercuric chloride: T helper cells reacting to self proteins.

Authors:  M Kubicka-Muranyi; J Kremer; N Rottmann; B Lübben; R Albers; N Bloksma; R Lührmann; E Gleichmann
Journal:  Int Arch Allergy Immunol       Date:  1996-01       Impact factor: 2.749

7.  The incidence of cancer following total hip replacement.

Authors:  W J Gillespie; C M Frampton; R J Henderson; P M Ryan
Journal:  J Bone Joint Surg Br       Date:  1988-08

8.  Characterization of nickel-specific T cell clones.

Authors:  S Silvennoinen-Kassinen; K Poikonen; I Ikäheimo
Journal:  Scand J Immunol       Date:  1991-04       Impact factor: 3.487

9.  Production of monoclonal antibodies to study corrosion products of CO-CR biomaterials.

Authors:  J Yang; K Merritt
Journal:  J Biomed Mater Res       Date:  1996-05

10.  Self-reactive anti-class II T helper type 2 cell lines derived from gold salt-injected rats trigger B cell polycolonal activation and transfer autoimmunity in CD8-depleted normal syngeneic recipients.

Authors:  A Saoudi; M Castedo; D Nochy; C Mandet; R Pasquier; P Druet; L Pelletier
Journal:  Eur J Immunol       Date:  1995-07       Impact factor: 5.532

View more
  21 in total

Review 1.  New insights into wear and biological effects of metal-on-metal bearings.

Authors:  Isabelle Catelas; Markus A Wimmer
Journal:  J Bone Joint Surg Am       Date:  2011-05       Impact factor: 5.284

Review 2.  Polyethylene and metal wear particles: characteristics and biological effects.

Authors:  Isabelle Catelas; Markus A Wimmer; Sandra Utzschneider
Journal:  Semin Immunopathol       Date:  2011-01-26       Impact factor: 9.623

Review 3.  Metallic debris from metal-on-metal total hip arthroplasty regulates periprosthetic tissues.

Authors:  Christoph H Lohmann; Gurpal Singh; Hans-Georg Willert; Gottfried H Buchhorn
Journal:  World J Orthop       Date:  2014-11-18

4.  Pleomorphic clinical spectrum of metallosis in total hip arthroplasty.

Authors:  Francesco Pisanu; Carlo Doria; Matteo Andreozzi; Marco Bartoli; Laura Saderi; Giovanni Sotgiu; Paolo Tranquilli Leali
Journal:  Int Orthop       Date:  2018-09-29       Impact factor: 3.075

Review 5.  The biological response to orthopaedic implants for joint replacement: Part I: Metals.

Authors:  Emmanuel Gibon; Derek F Amanatullah; Florence Loi; Jukka Pajarinen; Akira Nabeshima; Zhenyu Yao; Moussa Hamadouche; Stuart B Goodman
Journal:  J Biomed Mater Res B Appl Biomater       Date:  2016-06-21       Impact factor: 3.368

6.  Biocompatibility evaluation of a novel hydroxyapatite-polymer coating for medical implants (in vitro tests).

Authors:  Gabriela Negroiu; Roxana M Piticescu; Gabrielle C Chitanu; Ion N Mihailescu; Livia Zdrentu; Marimona Miroiu
Journal:  J Mater Sci Mater Med       Date:  2007-11-08       Impact factor: 3.896

Review 7.  Hypersensitivity to titanium: a less explored area of research.

Authors:  Vasantha Vijayaraghavan; Ajay V Sabane; K Tejas
Journal:  J Indian Prosthodont Soc       Date:  2012-07-13

8.  The John Charnley Award: Metal-on-metal hip resurfacing versus large-diameter head metal-on-metal total hip arthroplasty: a randomized clinical trial.

Authors:  Donald S Garbuz; Michael Tanzer; Nelson V Greidanus; Bassam A Masri; Clive P Duncan
Journal:  Clin Orthop Relat Res       Date:  2009-08-21       Impact factor: 4.176

9.  The Biologic Response to Bearing Materials.

Authors:  Emmanuel Gibon; Stuart B Goodman
Journal:  Orthop Knowl Online       Date:  2016-06

Review 10.  [Particle release in metal-on-metal bearings. A risk analysis].

Authors:  C Heisel; M Thomsen; E Jakubowitz; J P Kretzer
Journal:  Orthopade       Date:  2008-07       Impact factor: 1.087

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.