Literature DB >> 704667

RF magnetic field penetration, phase shift and power dissipation in biological tissue: implications for NMR imaging.

P A Bottomley, E R Andrew.   

Abstract

The magnetic field penetration, phase shift and power deposition in planar and cylindrical models of biological tissue exposed to a sinusoidal time-dependent magnetic field have been investigated theoretically over the frequency range 1 to 100 MHz. The results are based on measurements of the relative permittivity and resistivity dispersions of a variety of freshly excised rat tissue at 37 and 25 degrees C, and are analysed in terms of their implications for human body nuclear magnetic resonance (NMR) imaging. The results indicate that at NMR operating frequencies much greater than about 30 MHz, magnetic field amplitude and phase variations experienced by the nuclei may cause serious distortions in an image of a human torso. The maximum power deposition envisaged during an NMR imaging experiment on a human torso is likely to be comparable to existing long-term safe exposure levels, and will depend ultimately on the imaging technique and NMR frequency employed.

Entities:  

Mesh:

Year:  1978        PMID: 704667     DOI: 10.1088/0031-9155/23/4/006

Source DB:  PubMed          Journal:  Phys Med Biol        ISSN: 0031-9155            Impact factor:   3.609


  64 in total

1.  Lumped-element planar strip array (LPSA) for parallel MRI.

Authors:  Ray F Lee; Christopher J Hardy; Daniel K Sodickson; Paul A Bottomley
Journal:  Magn Reson Med       Date:  2004-01       Impact factor: 4.668

Review 2.  In Vivo pO2 Imaging of Tumors: Oxymetry with Very Low-Frequency Electron Paramagnetic Resonance.

Authors:  Boris Epel; Howard J Halpern
Journal:  Methods Enzymol       Date:  2015-09-26       Impact factor: 1.600

3.  Small tip angle three-dimensional tailored radiofrequency slab-select pulse for reduced B1 inhomogeneity at 3 T.

Authors:  Suwit Saekho; Fernando E Boada; Douglas C Noll; V Andrew Stenger
Journal:  Magn Reson Med       Date:  2005-02       Impact factor: 4.668

4.  High-resolution black-blood MRI of the carotid vessel wall using phased-array coils at 1.5 and 3 Tesla.

Authors:  Seshasailaja Anumula; Hee Kwon Song; Alexander C Wright; Felix W Wehrli
Journal:  Acad Radiol       Date:  2005-12       Impact factor: 3.173

5.  Optimizing the intrinsic signal-to-noise ratio of MRI strip detectors.

Authors:  Ananda Kumar; Paul A Bottomley
Journal:  Magn Reson Med       Date:  2006-07       Impact factor: 4.668

6.  Optimized quadrature surface coil designs.

Authors:  Ananda Kumar; Paul A Bottomley
Journal:  MAGMA       Date:  2007-12-04       Impact factor: 2.310

7.  An RF dosimeter for independent SAR measurement in MRI scanners.

Authors:  Di Qian; Abdel-Monem M El-Sharkawy; Paul A Bottomley; William A Edelstein
Journal:  Med Phys       Date:  2013-12       Impact factor: 4.071

8.  T1 weighted brain images at 7 Tesla unbiased for Proton Density, T2* contrast and RF coil receive B1 sensitivity with simultaneous vessel visualization.

Authors:  Pierre-François Van de Moortele; Edwards J Auerbach; Cheryl Olman; Essa Yacoub; Kâmil Uğurbil; Steen Moeller
Journal:  Neuroimage       Date:  2009-02-20       Impact factor: 6.556

9.  Phase-encoded single-voxel magnetic resonance spectroscopy for suppressing outer volume signals at 7 Tesla.

Authors:  Ningzhi Li; Li An; Christopher Johnson; Jun Shen
Journal:  Biomed Spectrosc Imaging       Date:  2017-12-27

Review 10.  Numerical field calculations considering the human subject for engineering and safety assurance in MRI.

Authors:  Christopher M Collins
Journal:  NMR Biomed       Date:  2009-11       Impact factor: 4.044

View more