Literature DB >> 6826708

Enhanced detection of bacteremia with a new BACTEC resin blood culture medium.

P C Appelbaum, D G Beckwith, J R Dipersio, J W Dyke, J F Salventi, L L Stone.   

Abstract

In this multicenter study, 621 sets of blood culture specimens were drawn from 280 patients who were suspected of being septic and who were receiving antimicrobial therapy. Equal volumes of each specimen were inoculated into BACTEC 6B and 16B media. The 16B medium contained adsorbent and cationic resins for neutralizing the effects of the drugs. Of the 621 sets drawn, there were 72 positive cultures in 16B and 52 positive cultures in 6B. In 23 cases the organism was detected only in the 16B medium, and in 3 cases the organism was detected in 6B only. The remaining 49 positives were detected in both culture bottles. In 13 of these 49 cultures, detection in 16B was made between 1 and 5 days earlier than in 6B, whereas 3 of 49 specimens were detected 1 day earlier in 6B; the remaining 33 cultures became positive at approximately the same time in both media. There were a total of 43 patients with positive cultures in this study. Of these patients, 28 had sepsis detected in both the 16B and 6B media. The 6B medium alone detected an additional three cases of sepsis, and the 16B resin medium alone identified 12 additional cases. Supplementary culturing of samples from patients receiving antimicrobial therapy significantly increased the number of positive cultures and positive patients, as well as significantly shortening the time to positivity in these cultures.

Entities:  

Mesh:

Substances:

Year:  1983        PMID: 6826708      PMCID: PMC272571          DOI: 10.1128/jcm.17.1.48-51.1983

Source DB:  PubMed          Journal:  J Clin Microbiol        ISSN: 0095-1137            Impact factor:   5.948


  5 in total

1.  Practical aerobic membrane filtration blood culture technique: clinical blood culture trial.

Authors:  N M Sullivan; V L Sutter; S M Finegold
Journal:  J Clin Microbiol       Date:  1975-01       Impact factor: 5.948

2.  Rapid isolation of bacteria from septicemic patients by use of an antimicrobial agent removal device.

Authors:  C Wallis; J L Melnick; R D Wende; P E Riely
Journal:  J Clin Microbiol       Date:  1980-05       Impact factor: 5.948

3.  Evaluation of the Antibiotic Removal Device.

Authors:  M D Appleman; R S Swinney; P N Heseltine
Journal:  J Clin Microbiol       Date:  1982-02       Impact factor: 5.948

4.  In vitro antibiotic removal and bacterial recovery from blood with an antibiotic removal device.

Authors:  N J Lindsey; P E Riely
Journal:  J Clin Microbiol       Date:  1981-03       Impact factor: 5.948

5.  Detection of group D and viridans streptococci in blood by radiometric methods.

Authors:  D G Beckwith
Journal:  J Clin Microbiol       Date:  1979-01       Impact factor: 5.948

  5 in total
  28 in total

1.  Performance of a BACTEC nonradiometric medium for pediatric blood cultures.

Authors:  J A Morello; S M Matushek; W M Dunne; D B Hinds
Journal:  J Clin Microbiol       Date:  1991-02       Impact factor: 5.948

2.  Performance of a new combination of blood culture vials in sepsis detection: a 2-year retrospective comparison.

Authors:  Paolo Bottino; Fabio Rapallo; Elisa Gamalero; Andrea Rocchetti
Journal:  Eur J Clin Microbiol Infect Dis       Date:  2019-05-08       Impact factor: 3.267

3.  Controlled comparative evaluation of BacT/Alert FAN and ESP 80A aerobic media as means for detecting bacteremia and fungemia.

Authors:  G V Doern; A Barton; S Rao
Journal:  J Clin Microbiol       Date:  1998-09       Impact factor: 5.948

4.  Detection of bacteria in the presence of antibiotics by using specific monoclonal antibodies to neutralize the antibiotics.

Authors:  J G Sierra-Madero; M J Caulfield; G S Hall; J A Washington
Journal:  J Clin Microbiol       Date:  1988-09       Impact factor: 5.948

5.  Neutralization of antimicrobial substances in new BacT/Alert FA and FN Plus blood culture bottles.

Authors:  Dieter Mitteregger; Wolfgang Barousch; Marion Nehr; Michael Kundi; Markus Zeitlinger; Athanasios Makristathis; Alexander M Hirschl
Journal:  J Clin Microbiol       Date:  2013-03-13       Impact factor: 5.948

6.  Validation of the Microbiological Testing of Tissue Preparations Using the BACTEC™ Blood Culture System.

Authors:  Jan Schroeter; Ina Wilkemeyer; Reinhold A Schiller; Axel Pruss
Journal:  Transfus Med Hemother       Date:  2012-11-21       Impact factor: 3.747

7.  Isolation of Corynebacterium aquaticum from spinal fluid of an infant with meningitis.

Authors:  D G Beckwith; J A Jahre; S Haggerty
Journal:  J Clin Microbiol       Date:  1986-02       Impact factor: 5.948

8.  Evaluation of the BACTEC antimicrobial removal system for detection of bacteremia.

Authors:  N M McGuire; C A Kauffman; C S Hertz; J M Kovach
Journal:  J Clin Microbiol       Date:  1983-09       Impact factor: 5.948

9.  In vitro evaluation of the BACTEC resin-containing blood culture bottle.

Authors:  S M Smith; R H Eng
Journal:  J Clin Microbiol       Date:  1983-06       Impact factor: 5.948

10.  High risk of streptococcal septicemia after high dose cytosine arabinoside treatment for acute myelogenous leukemia.

Authors:  W Kern; E Kurrle; E Vanek
Journal:  Klin Wochenschr       Date:  1987-08-17
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.