Literature DB >> 2007644

Performance of a BACTEC nonradiometric medium for pediatric blood cultures.

J A Morello1, S M Matushek, W M Dunne, D B Hinds.   

Abstract

A BACTEC aerobic nonradiometric medium, PEDS Plus, designed for diagnosis of pediatric bacteremia was evaluated in three hospital centers. Equivalent blood volumes (up to 5 ml) were inoculated into and incubated in BACTEC NR-6A (6A) and PEDS Plus broths. Among 4,581 compliant sets, 289 clinically significant organisms, representing more than 20 bacterial and two Candida species, were isolated. One hundred eighty-one isolates were recovered in both bottles, 75 in PEDS Plus only, and 33 in 6A only (P less than 0.001). Time to detection when both bottles were positive was the same for 129 isolates, detection with PEDS Plus was earlier for 39, and detection with 6A was earlier for 13 (P less than 0.005). Staphylococcus aureus was recovered significantly more often in PEDS Plus than in 6A (P less than 0.01), and more coagulase-negative staphylococci and pediatric pathogens (pneumococci, Haemophilus influenzae, and Streptococcus agalactiae) were recovered in PEDS Plus than in 6A. Coagulase-negative staphylococci and H. influenzae were detected significantly earlier in PEDS Plus (P less than 0.05 and less than 0.01, respectively). When the eight species of the family Enterobacteriaceae isolated were considered together, recovery in PEDS Plus was better than in 6A (P less than 0.05). For 66 of the 143 isolates from patients known to be on antimicrobial therapy at the time blood was drawn, PEDS Plus was superior to 6A. In 45 cases, organisms were isolated from PEDS Plus only (P less than 0.001) and in 21 cases they were isolated from PEDS Plus before 6A (P less than 0.01). PEDS Plus broth aids diagnosis of pediatric bacteremia by increasing recovery of etiologic agents and decreasing the time required for detection.

Entities:  

Mesh:

Substances:

Year:  1991        PMID: 2007644      PMCID: PMC269767          DOI: 10.1128/jcm.29.2.359-362.1991

Source DB:  PubMed          Journal:  J Clin Microbiol        ISSN: 0095-1137            Impact factor:   5.948


  11 in total

1.  Controlled evaluation of blood culture medium containing gelatin and V-factor-analog for detection of septicemia in children.

Authors:  C W Stratton; M P Weinstein; S Mirrett; J Paisley; B A Lauer; L B Reller
Journal:  J Clin Microbiol       Date:  1988-04       Impact factor: 5.948

2.  Gelatin neutralization of the inhibitory effect of sodium polyanethol sulfonate on Neisseria meningitidis in blood culture media.

Authors:  J Eng; E Holten
Journal:  J Clin Microbiol       Date:  1977-07       Impact factor: 5.948

Review 3.  Detection of bloodstream infections in children.

Authors:  J M Campos
Journal:  Eur J Clin Microbiol Infect Dis       Date:  1989-09       Impact factor: 3.267

4.  Routine evaluation of BACTEC NR-16A and NR-17A media.

Authors:  R J Courcol; A V Durocher; M Roussel-Delvallez; A Fruchart; G R Martin
Journal:  J Clin Microbiol       Date:  1988-09       Impact factor: 5.948

Review 5.  Blood cultures: issues and controversies.

Authors:  J A Washington; D M Ilstrup
Journal:  Rev Infect Dis       Date:  1986 Sep-Oct

6.  Use of sodium polyanethol sulfonate to selectively inhibit aminoglycoside and polymyxin antibiotics in a rapid blood level antibiotic assay.

Authors:  S C Edberg; C J Bottenbley; K Gam
Journal:  Antimicrob Agents Chemother       Date:  1976-03       Impact factor: 5.191

7.  Septicemia in children with cancer.

Authors:  L F Favor; M Tarpay; R Blackstock
Journal:  South Med J       Date:  1979-02       Impact factor: 0.954

8.  Enhanced detection of bacteremia with a new BACTEC resin blood culture medium.

Authors:  P C Appelbaum; D G Beckwith; J R Dipersio; J W Dyke; J F Salventi; L L Stone
Journal:  J Clin Microbiol       Date:  1983-01       Impact factor: 5.948

9.  Evaluation of the BACTEC resin blood-culture medium.

Authors:  C L Strand; A Hickman; J K Bryant; K Sutton
Journal:  Am J Clin Pathol       Date:  1983-11       Impact factor: 2.493

10.  Anaerobic bacteremia in a neonatal intensive care unit: an eighteen-year experience.

Authors:  G J Noel; D A Laufer; P J Edelson
Journal:  Pediatr Infect Dis J       Date:  1988-12       Impact factor: 2.129

View more
  14 in total

1.  Evaluation of manufacturer's recommended growth value thresholds for BACTEC media.

Authors:  A G Matlow; S Camack; B Taylor; B Burkholder
Journal:  J Clin Microbiol       Date:  1992-10       Impact factor: 5.948

2.  Comparison of the Bactec Peds Plus pediatric blood culture vial with Roche pediatric Septi-Chek for blood cultures from pediatric patients.

Authors:  P L Welby; T M Zusag; G A Storch
Journal:  J Clin Microbiol       Date:  1992-05       Impact factor: 5.948

3.  Determination of growth value thresholds for BACTEC PLUS aerobic blood culture vials.

Authors:  J E McGowan; B G Metchock
Journal:  J Clin Microbiol       Date:  1992-04       Impact factor: 5.948

4.  High diagnostic value of synovial biopsy in periprosthetic joint infection of the hip.

Authors:  Bernd Fink; Alexander Gebhard; Martin Fuerst; Irina Berger; Peter Schäfer
Journal:  Clin Orthop Relat Res       Date:  2012-07-18       Impact factor: 4.176

5.  Biographical feature: Josephine Morello, Ph.D.

Authors:  Betty A Forbes
Journal:  J Clin Microbiol       Date:  2014-09-10       Impact factor: 5.948

6.  Comparison of the BacT/Alert pediatric blood culture system, Pedi-BacT, with conventional culture using the 20-milliliter Becton-Dickinson supplemented peptone broth tube.

Authors:  K K Krisher; D R Whyburn; F E Koepnick
Journal:  J Clin Microbiol       Date:  1993-04       Impact factor: 5.948

7.  Controlled comparison of bioMérieux VITAL and BACTEC NR-660 systems for detection of bacteremia and fungemia in pediatric patients.

Authors:  A K Zaidi; S Mirrett; J C McDonald; E E Rubin; L C McDonald; M P Weinstein; M Gupta; L B Reller
Journal:  J Clin Microbiol       Date:  1997-08       Impact factor: 5.948

8.  The Japanese Clinical Practice Guidelines for Management of Sepsis and Septic Shock 2016 (J-SSCG 2016).

Authors:  Osamu Nishida; Hiroshi Ogura; Moritoki Egi; Seitaro Fujishima; Yoshiro Hayashi; Toshiaki Iba; Hitoshi Imaizumi; Shigeaki Inoue; Yasuyuki Kakihana; Joji Kotani; Shigeki Kushimoto; Yoshiki Masuda; Naoyuki Matsuda; Asako Matsushima; Taka-Aki Nakada; Satoshi Nakagawa; Shin Nunomiya; Tomohito Sadahiro; Nobuaki Shime; Tomoaki Yatabe; Yoshitaka Hara; Kei Hayashida; Yutaka Kondo; Yuka Sumi; Hideto Yasuda; Kazuyoshi Aoyama; Takeo Azuhata; Kent Doi; Matsuyuki Doi; Naoyuki Fujimura; Ryota Fuke; Tatsuma Fukuda; Koji Goto; Ryuichi Hasegawa; Satoru Hashimoto; Junji Hatakeyama; Mineji Hayakawa; Toru Hifumi; Naoki Higashibeppu; Katsuki Hirai; Tomoya Hirose; Kentaro Ide; Yasuo Kaizuka; Tomomichi Kan'o; Tatsuya Kawasaki; Hiromitsu Kuroda; Akihisa Matsuda; Shotaro Matsumoto; Masaharu Nagae; Mutsuo Onodera; Tetsu Ohnuma; Kiyohiro Oshima; Nobuyuki Saito; So Sakamoto; Masaaki Sakuraya; Mikio Sasano; Norio Sato; Atsushi Sawamura; Kentaro Shimizu; Kunihiro Shirai; Tetsuhiro Takei; Muneyuki Takeuchi; Kohei Takimoto; Takumi Taniguchi; Hiroomi Tatsumi; Ryosuke Tsuruta; Naoya Yama; Kazuma Yamakawa; Chizuru Yamashita; Kazuto Yamashita; Takeshi Yoshida; Hiroshi Tanaka; Shigeto Oda
Journal:  Acute Med Surg       Date:  2018-02-05

9.  Comparative study of three different BACTEC culture media for the detection of bacteremia in ambulatory and hospitalized children.

Authors:  D L Church; H D Davies; G Cadrain; C L Trevenen
Journal:  Can J Infect Dis       Date:  1998-03

10.  Comparison of Isolator 1.5 and BACTEC NR660 aerobic 6A blood culture systems for detection of fungemia in children.

Authors:  C A Petti; A K Zaidi; S Mirrett; L B Reller
Journal:  J Clin Microbiol       Date:  1996-08       Impact factor: 5.948

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.