Rapid isolation of bacteria from septicemic patients by use of an antimicrobial agent removal device.

C Wallis, J L Melnick, R D Wende, P E Riely.   

Abstract

The new Antimicrobial Removal Device increased the efficacy of conventional methods for isolating bacteria from the blood of septicemic patients. The device removes as much as 100 microgram of antibiotics per ml from whole blood without a significant decrease in bacteria. Of 51 patients studied, 31 yielded positive cultures, and the Antimicrobial Removal Device permitted earlier isolation of the causative agent from blood. Subcultured within the first 12 h yielded 12 positive isolates, as the 31 agents were isolated more rapidly after Antimicrobial Removal Device permitted earlier isolation of the causative agent from blood. Subcultures within the first 12 h yielded 12 positive isolates, as compared to 2 when subcultured without processing in the device. Overall, 21 of the 31 agents were isolated more rapidly after Antimicrobial Removal Device treatment, and four samples were positive only after such treatment. One agent was not isolated in the treated culture.

Entities:  

Mesh:

Substances:

Year:  1980        PMID: 6769953      PMCID: PMC273432          DOI: 10.1128/jcm.11.5.462-464.1980

Source DB:  PubMed          Journal:  J Clin Microbiol        ISSN: 0095-1137            Impact factor:   5.948


  4 in total

1.  Practical aerobic membrane filtration blood culture technique: clinical blood culture trial.

Authors:  N M Sullivan; V L Sutter; S M Finegold
Journal:  J Clin Microbiol       Date:  1975-01       Impact factor: 5.948

2.  Effect of blood dilution on recovery of organisms from clinical blood cultures in medium containing sodium polyanethol sulfonate.

Authors:  J F Salventi; T A Davies; E L Randall; S Whitaker; J R Waters
Journal:  J Clin Microbiol       Date:  1979-02       Impact factor: 5.948

3.  Effect of dilution on recovery of bacteria from blood.

Authors:  J L Beebe; K A Bourne; P D Ellner
Journal:  J Clin Microbiol       Date:  1977-04       Impact factor: 5.948

4.  Automated radiometric detection of bacterial growth in blood cultures.

Authors:  F DeLand; H N Wagner
Journal:  J Lab Clin Med       Date:  1970-03
  4 in total
  23 in total

1.  Detection of borreliacidal antibodies in Lyme borreliosis patient sera containing antimicrobial agents.

Authors:  D A Jobe; N Rawal; R F Schell; S M Callister
Journal:  Clin Diagn Lab Immunol       Date:  1999-11

2.  Effectiveness of resins in neutralizing antibiotic activities in bactec plus Aerobic/F culture medium.

Authors:  J Spaargaren; C P van Boven; G P Voorn
Journal:  J Clin Microbiol       Date:  1998-12       Impact factor: 5.948

3.  Detection of bacteria in the presence of antibiotics by using specific monoclonal antibodies to neutralize the antibiotics.

Authors:  J G Sierra-Madero; M J Caulfield; G S Hall; J A Washington
Journal:  J Clin Microbiol       Date:  1988-09       Impact factor: 5.948

4.  Validation of the Microbiological Testing of Tissue Preparations Using the BACTEC™ Blood Culture System.

Authors:  Jan Schroeter; Ina Wilkemeyer; Reinhold A Schiller; Axel Pruss
Journal:  Transfus Med Hemother       Date:  2012-11-21       Impact factor: 3.747

Review 5.  Pulmonary infections in immunocompromised children.

Authors:  V P Choudhry; S Choudhary
Journal:  Indian J Pediatr       Date:  1989 Nov-Dec       Impact factor: 1.967

6.  Routine evaluation of BACTEC NR-16A and NR-17A media.

Authors:  R J Courcol; A V Durocher; M Roussel-Delvallez; A Fruchart; G R Martin
Journal:  J Clin Microbiol       Date:  1988-09       Impact factor: 5.948

7.  Evaluation of the BACTEC antimicrobial removal system for detection of bacteremia.

Authors:  N M McGuire; C A Kauffman; C S Hertz; J M Kovach
Journal:  J Clin Microbiol       Date:  1983-09       Impact factor: 5.948

8.  In vitro evaluation of the BACTEC resin-containing blood culture bottle.

Authors:  S M Smith; R H Eng
Journal:  J Clin Microbiol       Date:  1983-06       Impact factor: 5.948

9.  Enhanced detection of bacteremia with a new BACTEC resin blood culture medium.

Authors:  P C Appelbaum; D G Beckwith; J R Dipersio; J W Dyke; J F Salventi; L L Stone
Journal:  J Clin Microbiol       Date:  1983-01       Impact factor: 5.948

10.  Effectiveness of the antimicrobial removal device, BACTEC 16B medium, and thiol broth in neutralizing antibacterial activities of imipenem, norfloxacin, and related agents.

Authors:  E Weinberg; D L Shungu; H H Gadebusch
Journal:  J Clin Microbiol       Date:  1984-02       Impact factor: 5.948

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.