Literature DB >> 23486710

Neutralization of antimicrobial substances in new BacT/Alert FA and FN Plus blood culture bottles.

Dieter Mitteregger1, Wolfgang Barousch, Marion Nehr, Michael Kundi, Markus Zeitlinger, Athanasios Makristathis, Alexander M Hirschl.   

Abstract

Time to detection (TTD) in automated blood culture systems is delayed for sensitive microorganisms in the presence of antimicrobial substances and has been associated with worse outcomes for sepsis patients on inadequate empirical therapy. While resin addition removes antimicrobial substances to various degrees from blood culture media, media formulations and the blend of resins may influence performance. The BacT/Alert 3D system (bioMérieux) was investigated using the new resin-containing medium types FA Plus (aerobic) and FN Plus (anaerobic). TTD was compared between control and test bottles containing relevant bacteria or Candida albicans, with and without defined concentrations of antimicrobials. Failure of neutralization was defined as a negative blood culture on day 3. In general, growth delay was nonlinear, concentration dependent, bottle type specific, and reciprocally associated with MICs. Substance-specific serum drug concentrations corresponding to a predefined, clinically relevant 3-h delay of TTD were calculated. Where appropriate, a time interval allowing for drug elimination below this critical level was obtained by pharmacokinetic modeling. Clarithromycin, clindamycin, gentamicin, linezolid, tigecycline, vancomycin, and fluconazole were neutralized. For ciprofloxacin and piperacillin-tazobactam, which were only incompletely neutralized in combination with the most sensitive test strains, a maximum waiting time for blood draw of 1 h was determined based on pharmacokinetics. One or more test strains did not grow in bottles containing either amoxicillin-clavulanate, cefepime, cefotaxime, meropenem, or metronidazole, and we thus recommend particular caution in timing of blood draws if patients have been pretreated with these agents.

Entities:  

Mesh:

Substances:

Year:  2013        PMID: 23486710      PMCID: PMC3647900          DOI: 10.1128/JCM.00103-13

Source DB:  PubMed          Journal:  J Clin Microbiol        ISSN: 0095-1137            Impact factor:   5.948


  30 in total

1.  Target site concentrations of ciprofloxacin after single intravenous and oral doses.

Authors:  Martin Brunner; Heino Stabeta; Jan-Georg Möller; Claudia Schrolnberger; Boban Erovic; Ursula Hollenstein; Markus Zeitlinger; Hans Georg Eichler; Markus Müller
Journal:  Antimicrob Agents Chemother       Date:  2002-12       Impact factor: 5.191

2.  Should antibiotics be discontinued at 48 hours for negative late-onset sepsis evaluations in the neonatal intensive care unit?

Authors:  Jeffrey R Kaiser; James E Cassat; Mary Jo Lewno
Journal:  J Perinatol       Date:  2002-09       Impact factor: 2.521

3.  Pharmacokinetics and tissue penetration of tazobactam and piperacillin in patients undergoing colorectal surgery.

Authors:  M Kinzig; F Sörgel; B Brismar; C E Nord
Journal:  Antimicrob Agents Chemother       Date:  1992-09       Impact factor: 5.191

4.  What happens when automated blood culture instrument detect growth but there are no technologists in the microbiology laboratory?

Authors:  Thomas Savinelli; Stephen Parenteau; Leonard A Mermel
Journal:  Diagn Microbiol Infect Dis       Date:  2004-03       Impact factor: 2.803

5.  Use of simulated blood cultures for antibiotic effect on time to detection of the two blood culture systems BacT/ALERT and BACTEC 9240.

Authors:  E F Viganò; E Vasconi; C Agrappi; P Clerici; P Melloni
Journal:  New Microbiol       Date:  2004-07       Impact factor: 2.479

6.  Comparison of the Bactec Fx Plus, Mycosis IC/F, Mycosis/F Lytic blood culture media and the BacT/Alert 3D FA media for detection of Candida species in seeded blood culture specimens containing therapeutic peak levels of fluconazole.

Authors:  Dong Wook Jekarl; So-Young Lee; Seungok Lee; Yeon-Joon Park; Jehoon Lee; Sun Mi Baek; Yeon Ju An; Sun Myeong Ock; Mi-Kyung Lee
Journal:  J Clin Lab Anal       Date:  2012-11       Impact factor: 2.352

7.  Interference of antibiotic therapy on blood cultures time-to-positivity: analysis of a 5-year experience in an oncological hospital.

Authors:  R Passerini; D Riggio; D Radice; L Bava; C Cassatella; M Salvatici; L Zorzino; M T Sandri
Journal:  Eur J Clin Microbiol Infect Dis       Date:  2008-07-29       Impact factor: 3.267

8.  Enhanced detection of bacteremia with a new BACTEC resin blood culture medium.

Authors:  P C Appelbaum; D G Beckwith; J R Dipersio; J W Dyke; J F Salventi; L L Stone
Journal:  J Clin Microbiol       Date:  1983-01       Impact factor: 5.948

9.  Penetration of meropenem into pneumonic human lung tissue as measured by in vivo microdialysis.

Authors:  Florian Tomaselli; Alfred Maier; Veronika Matzi; Freyja Maria Smolle-Jüttner; Peter Dittrich
Journal:  Antimicrob Agents Chemother       Date:  2004-06       Impact factor: 5.191

10.  Comparative pharmacokinetics of sulbactam/ampicillin and clavulanic acid/amoxycillin in human volunteers.

Authors:  B Hampel; H Lode; G Bruckner; P Koeppe
Journal:  Drugs       Date:  1988       Impact factor: 9.546

View more
  18 in total

1.  High medical impact of implementing the new polymeric bead-based BacT/ALERT® FAPlus and FNPlus blood culture bottles in standard care.

Authors:  R Amarsy-Guerle; F Mougari; H Jacquier; J Oliary; H Benmansour; J Riahi; B Berçot; L Raskine; E Cambau
Journal:  Eur J Clin Microbiol Infect Dis       Date:  2015-02-04       Impact factor: 3.267

2.  Sepsis in standard care: patients' characteristics, effectiveness of antimicrobial therapy and patient outcome--a cohort study.

Authors:  Franz Ratzinger; Katharina Eichbichler; Michael Schuardt; Irene Tsirkinidou; Dieter Mitteregger; Helmuth Haslacher; Thomas Perkmann; Klaus G Schmetterer; Georg Doffner; Heinz Burgmann
Journal:  Infection       Date:  2015-04-04       Impact factor: 3.553

3.  A comparative evaluation of BACT/ALERT FA PLUS and FN PLUS blood culture bottles and BD BACTEC Plus Aerobic and Anaerobic blood culture bottles for antimicrobial neutralization.

Authors:  Yousun Chung; In-Hee Kim; Minje Han; Hyun Soo Kim; Han-Sung Kim; Wonkeun Song; Jae-Seok Kim
Journal:  Eur J Clin Microbiol Infect Dis       Date:  2019-08-02       Impact factor: 3.267

4.  Efficient Inactivation of Clinically Relevant Antimicrobial Drug Concentrations by BacT/Alert or Bactec Resin-Containing Media in Simulated Adult Blood Cultures.

Authors:  Teresa Spanu; Brunella Posteraro; Giulia Menchinelli; Flora Marzia Liotti; Liliana Giordano; Giulia De Angelis; Maurizio Sanguinetti
Journal:  Antimicrob Agents Chemother       Date:  2019-06-24       Impact factor: 5.191

5.  In vitro blood culture bottle inoculation of whole blood with clinically relevant antibiotic concentrations: a word of caution.

Authors:  M Grupper; J L Kuti; D P Nicolau
Journal:  Eur J Clin Microbiol Infect Dis       Date:  2016-12-28       Impact factor: 3.267

6.  Evaluation of bacterial contamination rate of the anterior chamber during phacoemulsification surgery using an automated microbial detection system.

Authors:  Ibrahim Kocak; Funda Kocak; Bahri Teker; Ali Aydin; Faruk Kaya; Hakan Baybora
Journal:  Int J Ophthalmol       Date:  2014-08-18       Impact factor: 1.779

Review 7.  Continuous and Prolonged Intravenous β-Lactam Dosing: Implications for the Clinical Laboratory.

Authors:  Mordechai Grupper; Joseph L Kuti; David P Nicolau
Journal:  Clin Microbiol Rev       Date:  2016-10       Impact factor: 26.132

8.  Recovery of Gram-Negative Bacteria from Aerobic Blood Culture Bottles Containing Antibiotic Binding Resins after Exposure to β-Lactam and Fluoroquinolone Concentrations.

Authors:  Iris H Chen; David P Nicolau; Joseph L Kuti
Journal:  J Clin Microbiol       Date:  2019-09-24       Impact factor: 5.948

9.  Performance of two resin-containing blood culture media in detection of bloodstream infections and in direct matrix-assisted laser desorption ionization-time of flight mass spectrometry (MALDI-TOF MS) broth assays for isolate identification: clinical comparison of the BacT/Alert Plus and Bactec Plus systems.

Authors:  Barbara Fiori; Tiziana D'Inzeo; Viviana Di Florio; Flavio De Maio; Giulia De Angelis; Alessia Giaquinto; Lara Campana; Eloisa Tanzarella; Mario Tumbarello; Massimo Antonelli; Maurizio Sanguinetti; Teresa Spanu
Journal:  J Clin Microbiol       Date:  2014-07-16       Impact factor: 5.948

10.  Clinical evaluation of BacT/Alert FA plus and FN plus bottles compared with standard bottles.

Authors:  Dong-Hyun Lee; Seong Chun Kim; In-Gyu Bae; Eun-Ha Koh; Sunjoo Kim
Journal:  J Clin Microbiol       Date:  2013-10-09       Impact factor: 5.948

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.