Literature DB >> 6646620

Evaluation and comparison of sources of variability in the measurement of corneal thickness with ultrasonic and optical pachymeters.

J J Salz, S P Azen, J Berstein, P Caroline, R A Villasenor, D J Schanzlin.   

Abstract

Two studies were carried out to determine and compare the effects of several sources of variation on the measurement of corneal thickness using the standard optical pachymeter and three ultrasonic pachymeters. Sources of variation included: intra- and inter-session variation, inter-observer variation, left/right eye variation, and variations due to alternate settings of ultrasonic sound frequencies. It was found that the optical pachymeter had a) two to three times as much intra-session variation as that of the ultrasound pachymeters, b) significant inter-observer variation (P = 0.015), and c) significant differences between left and right eye thickness determinations (P less than 0.005). On the other hand, ultrasonic pachymeters demonstrated a) high reproducibility, b) no inter-observer variation, and c) no left/right eye variation. These results have implications for the use of pachymetry in measuring corneal thickness for radial keratotomy and other refractive surgery.

Entities:  

Mesh:

Year:  1983        PMID: 6646620

Source DB:  PubMed          Journal:  Ophthalmic Surg        ISSN: 0022-023X


  14 in total

1.  Evaluation of corneal thickness and topography in normal eyes using the Orbscan corneal topography system.

Authors:  Z Liu; A J Huang; S C Pflugfelder
Journal:  Br J Ophthalmol       Date:  1999-07       Impact factor: 4.638

2.  Intraobserver and interobserver reproducibility in the evaluation of ultrasonic pachymetry measurements of central corneal thickness.

Authors:  S Miglior; E Albe; M Guareschi; G Mandelli; S Gomarasca; N Orzalesi
Journal:  Br J Ophthalmol       Date:  2004-02       Impact factor: 4.638

3.  Corneal wound healing after photorefractive keratectomy: a 3-year confocal microscopy study.

Authors:  Jay C Erie
Journal:  Trans Am Ophthalmol Soc       Date:  2003

4.  Clinical estimation of corneal endothelial pump function.

Authors:  W M Bourne
Journal:  Trans Am Ophthalmol Soc       Date:  1998

5.  Photorefractive keratectomy for anisometropic amblyopia in children.

Authors:  Evelyn A Paysse
Journal:  Trans Am Ophthalmol Soc       Date:  2004

6.  The effect of corneal thickness on intraocular pressure measurement in patients with corneal pathology.

Authors:  A C Browning; A Bhan; A P Rotchford; S Shah; H S Dua
Journal:  Br J Ophthalmol       Date:  2004-11       Impact factor: 4.638

7.  Central corneal thickness in Northwestern American Indians/Alaskan Natives and comparison with White and African-American persons.

Authors:  Rodrigo J Torres; Emily Jones; Beth Edmunds; Thomas Becker; George A Cioffi; Steven L Mansberger
Journal:  Am J Ophthalmol       Date:  2008-07-30       Impact factor: 5.258

8.  Comparison of central corneal thickness measurements by Pentacam, noncontact specular microscope, and ultrasound pachymetry in normal and post-LASIK eyes.

Authors:  Saleh Al-Ageel; Abdulrahman M Al-Muammar
Journal:  Saudi J Ophthalmol       Date:  2009-10-24

9.  Corneal thickness in nephropathic cystinosis.

Authors:  B Katz; R B Melles; J A Schneider; N A Rao
Journal:  Br J Ophthalmol       Date:  1989-08       Impact factor: 4.638

10.  Comparison of central corneal thickness measurements using ultrasound pachymetry, ultrasound biomicroscopy, and the Artemis-2 VHF scanner in normal eyes.

Authors:  Haya M Al-Farhan; Wafa'a Majed Al-Otaibi
Journal:  Clin Ophthalmol       Date:  2012-07-06
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.