Literature DB >> 10381661

Evaluation of corneal thickness and topography in normal eyes using the Orbscan corneal topography system.

Z Liu1, A J Huang, S C Pflugfelder.   

Abstract

AIMS: To map the thickness, elevation (anterior and posterior corneal surface), and axial curvature of the cornea in normal eyes with the Orbscan corneal topography system.
METHODS: 94 eyes of 51 normal subjects were investigated using the Orbscan corneal topography system. The anterior and posterior corneal elevation maps were classified into regular ridge, irregular ridge, incomplete ridge, island, and unclassified patterns, and the axial power maps were grouped into round, oval, symmetric bow tie, asymmetric bow tie, and irregular patterns. The pachymetry patterns were designated as round, oval, decentred round, and decentred oval.
RESULTS: The thinnest point on the cornea was located at an average of 0.90 (SD 0. 51) mm from visual axis and had an average thickness of 0.55 (0.03) mm. In 69.57% of eyes, this point was located in the inferotemporal quadrant, followed by the superotemporal quadrant in 23.91%, the inferonasal quadrant in 4.35%, and the superonasal quadrant in 2.17%. Among the nine regions of the cornea evaluated (central, superotemporal, temporal, inferotemporal, inferior, inferonasal, nasal, superonasal, and superior) the central cornea had the lowest average thickness (0.56 (0.03) mm) and the superior cornea had the greatest average thickness (0.64 (0.03) mm). The mean simulated keratometry (SimK) was 44.24 (1.61)/43.31 (1.66) dioptres (D) and the mean astigmatism was 0.90 (0.41) D. Island (71.74%) was the most common elevation pattern observed in the anterior corneal surface, followed by incomplete ridge (19.57%), regular ridge (4.34%), irregular ridge (2.17%), and unclassified (2.17%). Island (32.61%) was the most common topographic pattern in the posterior corneal surface, following by regular ridge (30.43%), incomplete ridge (23. 91%), and irregular ridge (13.04%) patterns. Symmetric bow tie was the most common axial power pattern in the anterior cornea (39.13%), followed by oval (26.07%), asymmetric bow tie (23.91%), round (6. 52%), and irregular (4.53%) patterns. In the pachymetry maps, 47.83% of eyes had an oval pattern, and round, decentred oval, and decentred round were observed in 41.30%, 8.70%, and 2.18% of eyes, respectively.
CONCLUSION: The information on regional corneal thickness, corneal elevation and axial corneal curvature obtained with the Orbscan corneal topography system from normal eyes provides a reference for comparison with diseased corneas. The Orbscan corneal topography system is a useful tool to evaluate both corneal topography and corneal thickness.

Entities:  

Mesh:

Year:  1999        PMID: 10381661      PMCID: PMC1723104          DOI: 10.1136/bjo.83.7.774

Source DB:  PubMed          Journal:  Br J Ophthalmol        ISSN: 0007-1161            Impact factor:   4.638


  23 in total

Review 1.  Advances in the analysis of corneal topography.

Authors:  S E Wilson; S D Klyce
Journal:  Surv Ophthalmol       Date:  1991 Jan-Feb       Impact factor: 6.048

2.  Automatic recording of corneal thickness in vitro.

Authors:  S D Klyce; D M Maurice
Journal:  Invest Ophthalmol       Date:  1976-07

3.  Classification of normal corneal topography based on computer-assisted videokeratography.

Authors:  S J Bogan; G O Waring; O Ibrahim; C Drews; L Curtis
Journal:  Arch Ophthalmol       Date:  1990-07

4.  Study of human precorneal tear film thickness and structure using laser interferometry.

Authors:  J I Prydal; P Artal; H Woon; F W Campbell
Journal:  Invest Ophthalmol Vis Sci       Date:  1992-05       Impact factor: 4.799

5.  Positive correlation of corneal thickness and endothelial cell loss. Serial measurements after cataract surgery.

Authors:  H Cheng; A K Bates; L Wood; K McPherson
Journal:  Arch Ophthalmol       Date:  1988-07

6.  Comparison of ultrasonic corneal thickness measurements before and during surgery in the prospective evaluation of Radial Keratotomy (PERK) Study.

Authors:  R A Villaseñor; V R Santos; K C Cox; D F Harris; M Lynn; G O Waring
Journal:  Ophthalmology       Date:  1986-03       Impact factor: 12.079

7.  In vivo assessment of mechanisms controlling corneal hydration.

Authors:  M R O'Neal; K A Polse
Journal:  Invest Ophthalmol Vis Sci       Date:  1985-06       Impact factor: 4.799

8.  The corneal endothelium. Normal and pathologic structure and function.

Authors:  G O Waring; W M Bourne; H F Edelhauser; K R Kenyon
Journal:  Ophthalmology       Date:  1982-06       Impact factor: 12.079

9.  Measurement of corneal curvature after corneal transplantation and radial keratotomy using standard and automated keratometry.

Authors:  P S Binder
Journal:  CLAO J       Date:  1989 Jul-Sep
View more
  40 in total

1.  Posterior corneal topographic changes after partial flap during laser in situ keratomileusis.

Authors:  N Sharma; A Rani; R Balasubramanya; R B Vajpayee; R M Pandey
Journal:  Br J Ophthalmol       Date:  2003-02       Impact factor: 4.638

2.  Comparison of corneal thickness measurements using Orbscan II, non-contact specular microscopy, and ultrasonic pachymetry in eyes after laser in situ keratomileusis.

Authors:  K Kawana; T Tokunaga; K Miyata; F Okamoto; T Kiuchi; T Oshika
Journal:  Br J Ophthalmol       Date:  2004-04       Impact factor: 4.638

3.  The effects of corneal parameters on the assessment of endothelial cell density in the elderly eye.

Authors:  A Müller; J P Craig; C N Grupcheva; C N J McGhee
Journal:  Br J Ophthalmol       Date:  2004-03       Impact factor: 4.638

4.  Orbscan II-assisted intraocular lens power calculation for cataract surgery following myopic laser in situ keratomileusis (an American Ophthalmological Society thesis).

Authors:  Henry Gelender
Journal:  Trans Am Ophthalmol Soc       Date:  2006

5.  Comparison of anterior segment measurements using rotating Scheimpflug imaging and partial coherence interferometry.

Authors:  Mohammad Soleimani; Hassan Hashemi; Shiva Mehravaran; Mehdi Khabazkhoob; Mohammad Hassan Emamian; Mohammad Shariati; Akbar Fotouhi
Journal:  Int J Ophthalmol       Date:  2013-08-18       Impact factor: 1.779

6.  Characteristics of corneal topographic and pachymetric patterns in patients with pellucid marginal corneal degeneration.

Authors:  Mutsumi Fuchihata; Naoyuki Maeda; Ryotaro Toda; Shizuka Koh; Takashi Fujikado; Kohji Nishida
Journal:  Jpn J Ophthalmol       Date:  2013-12-03       Impact factor: 2.447

7.  Comparison of central corneal thickness measurements by Orbscan II and Pentacam after corneal refractive surgery.

Authors:  Jumpei Matsuda; Osamu Hieda; Shigeru Kinoshita
Journal:  Jpn J Ophthalmol       Date:  2008-09-05       Impact factor: 2.447

8.  Corneal pachymetry mapping with high-speed optical coherence tomography.

Authors:  Yan Li; Raj Shekhar; David Huang
Journal:  Ophthalmology       Date:  2006-05       Impact factor: 12.079

9.  Day to Day Clinically Relevant Corneal Elevation, Thickness, and Curvature Parameters Using the Orbscan II Scanning Slit Topographer and the Pentacam Scheimpflug Imaging Device.

Authors:  Hassan Hashemi; Shiva Mehravaran
Journal:  Middle East Afr J Ophthalmol       Date:  2010-01

10.  Comparison of central corneal thickness and anterior chamber depth measurements using three imaging technologies in normal eyes and after phakic intraocular lens implantation.

Authors:  Muriël Doors; Lars P J Cruysberg; Tos T J M Berendschot; John de Brabander; Frenne Verbakel; Carroll A B Webers; Rudy M M A Nuijts
Journal:  Graefes Arch Clin Exp Ophthalmol       Date:  2009-04-30       Impact factor: 3.117

View more