Variation in the abilities of automated, commercial, and reference methods to detect methicillin-resistant (heteroresistant) Staphylococcus aureus.

S L Hansen, P K Freedy.   

Abstract

The abilities of commercial MIC, automated, and reference methods for in vitro detection of methicillin-resistant Staphylococcus aureus were determined on 49 strains from eight hospitals. Micro-Media, MicroScan, Sensititre, Sceptor, API Uniscept KB, Abbott MS-2, Vitek AMS, Autobac MTS, NCCLS disk diffusion, and broth microdilution antimicrobial susceptibility testing procedures were evaluated. All testing was performed by using manufacturers' or reference procedures, and results were determined at no later than 24 h of incubation at 35 degrees C. With NCCLS disk diffusion, all strains were resistant to oxacillin (1 microgram), 47 (96%) were resistant to methicillin (4 micrograms), and 48 (98%) were resistant to nafcillin (1 microgram). The percentages of strains resistant to methicillin (greater than 8 micrograms/ml) were 98% with API Uniscept KB, 86% with Sceptor, MicroScan, and Autobac MTS, 84% with Sensititre, 71% with Micro-Media, and 70% with NCCLS MIC. Abbott MS-2 detected 86% of strains resistant to methicillin (greater than 5 micrograms/ml). With oxacillin (greater than 2 micrograms/ml), 90% were detected with Vitek AMS and 70% were detected with NCCLS MIC. With nafcillin (greater than 2 micrograms), 82% were resistant with Micro-Media, 57% were resistant by NCCLS MIC, and 50% (three of six) were resistant by MicroScan. Two strains from one hospital and one strain from another gave susceptible results with all automated and commercial methods. All strains from three centers were detected by all methods. Variability also occurred among the systems with cephalothin, clindamycin, gentamicin, chloramphenicol, and trimethoprim sulfamethoxazole.

Entities:  

Mesh:

Substances:

Year:  1984        PMID: 6490833      PMCID: PMC271358          DOI: 10.1128/jcm.20.3.494-499.1984

Source DB:  PubMed          Journal:  J Clin Microbiol        ISSN: 0095-1137            Impact factor:   5.948


  11 in total

1.  Methicillin-resistant Staphylococcus aureus susceptibility testing by an automated system, Autobac I.

Authors:  T J Cleary; D Maurer
Journal:  Antimicrob Agents Chemother       Date:  1978-05       Impact factor: 5.191

2.  Concurrent comparability of automated systems and commercially prepared microdilution trays for susceptibility testing.

Authors:  S L Hansen; P K Freedy
Journal:  J Clin Microbiol       Date:  1983-05       Impact factor: 5.948

3.  Examination of major disagreements in susceptibility test results by Autobac-1 and MS-2.

Authors:  N J Lindsey; W G Barnes
Journal:  Antimicrob Agents Chemother       Date:  1981-07       Impact factor: 5.191

4.  Detection of oxacillin-resistant staphylococci by the AutoMicrobic system.

Authors:  R W Stotler; M C Meyer
Journal:  J Clin Microbiol       Date:  1983-11       Impact factor: 5.948

5.  New recommendations for disk diffusion antimicrobial susceptibility tests for methicillin-resistant (heteroresistant) staphylococci.

Authors:  L K McDougal; C Thornsberry
Journal:  J Clin Microbiol       Date:  1984-04       Impact factor: 5.948

6.  Successful use of broth microdilution in susceptibility tests for methicillin-resistant (heteroresistant) staphylococci.

Authors:  C Thornsberry; L K McDougal
Journal:  J Clin Microbiol       Date:  1983-11       Impact factor: 5.948

7.  Reliability of the MS-2 system in detecting methicillin-resistant Staphylococcus aureus.

Authors:  J M Boyce; R L White; M C Bonner; W R Lockwood
Journal:  J Clin Microbiol       Date:  1982-02       Impact factor: 5.948

8.  Methicillin-resistant Staphylococcus aureus susceptibility testing with Abbott MS-2 system.

Authors:  J R Carlson; F E Conley; D L Cahall
Journal:  Antimicrob Agents Chemother       Date:  1982-04       Impact factor: 5.191

9.  Early detection of oxacillin-resistant staphylococcal strains with hypertonic broth diluent for microdilution panels.

Authors:  L K Dillon; S E Howe
Journal:  J Clin Microbiol       Date:  1984-04       Impact factor: 5.948

10.  Interlaboratory variation of antibiograms of methicillin-resistant and methicillin-susceptible Staphylococcus aureus strains with conventional and commercial testing systems.

Authors:  K E Aldridge; A Janney; C V Sanders; R L Marier
Journal:  J Clin Microbiol       Date:  1983-11       Impact factor: 5.948

View more
  20 in total

1.  Validation of the automated reading and incubation system with Sensititre plates for antimicrobial susceptibility testing.

Authors:  Kimberle C Chapin; Michael C Musgnug
Journal:  J Clin Microbiol       Date:  2003-05       Impact factor: 5.948

2.  Screening method for recovery of methicillin-resistant Staphylococcus aureus from primary plates.

Authors:  J G La Zonby; M J Starzyk
Journal:  J Clin Microbiol       Date:  1986-08       Impact factor: 5.948

Review 3.  Expert systems in clinical microbiology.

Authors:  Trevor Winstanley; Patrice Courvalin
Journal:  Clin Microbiol Rev       Date:  2011-07       Impact factor: 26.132

4.  Modification of the Sceptor system for rapid detection of methicillin-resistant staphylococci.

Authors:  G A Denys; D F Sahm
Journal:  J Clin Microbiol       Date:  1986-09       Impact factor: 5.948

Review 5.  Methicillin-resistant staphylococci: detection methods and treatment of infections.

Authors:  C J Hackbarth; H F Chambers
Journal:  Antimicrob Agents Chemother       Date:  1989-07       Impact factor: 5.191

6.  Salt-supplemented medium for testing methicillin-resistant staphylococci with newer beta-lactams.

Authors:  J H Jorgensen; J S Redding; L A Maher; P E Ramirez
Journal:  J Clin Microbiol       Date:  1988-09       Impact factor: 5.948

7.  Comparison of BIOGRAM and commercial microdilution antimicrobial susceptibility test systems.

Authors:  R L Sautter; G A Denys
Journal:  J Clin Microbiol       Date:  1987-02       Impact factor: 5.948

8.  Evaluation of the AutoMicrobic system Gram-Positive Susceptibility-MIC card for detection of oxacillin-resistant coagulase-negative staphylococci.

Authors:  B F Woolfrey; R T Lally; M N Ederer
Journal:  J Clin Microbiol       Date:  1986-03       Impact factor: 5.948

9.  Evaluation of the newly modified AutoMicrobic system gram-positive susceptibility-MIC card for detection of methicillin-resistant Staphylococcus aureus.

Authors:  R T Lally; M N Ederer; B F Woolfrey
Journal:  J Clin Microbiol       Date:  1986-02       Impact factor: 5.948

10.  Evaluation of laboratory tests for detection of methicillin-resistant Staphylococcus aureus and Staphylococcus epidermidis.

Authors:  P E Coudron; D L Jones; H P Dalton; G L Archer
Journal:  J Clin Microbiol       Date:  1986-11       Impact factor: 5.948

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.