Literature DB >> 588903

Epoxy resin based tissue substitutes.

D R White, R J Martin, R Darlison.   

Abstract

A series of epoxy resin based tissue substitutes, simulating adipose tissue, bone, breast, lung, muscle and skin is described. Details of the physical radiation characteristics of the formulated systems are given, together with the manufacturing procedures. The versatility of the range of substitutes is discussed in terms of both investigated and projected applications in experimental radiation studies.

Mesh:

Substances:

Year:  1977        PMID: 588903     DOI: 10.1259/0007-1285-50-599-814

Source DB:  PubMed          Journal:  Br J Radiol        ISSN: 0007-1285            Impact factor:   3.039


  20 in total

1.  Evaluation of a cone beam CT artefact reduction algorithm.

Authors:  B Bechara; C A McMahan; H Geha; M Noujeim
Journal:  Dentomaxillofac Radiol       Date:  2012-02-23       Impact factor: 2.419

2.  Deriving Hounsfield units using grey levels in cone beam computed tomography.

Authors:  P Mah; T E Reeves; W D McDavid
Journal:  Dentomaxillofac Radiol       Date:  2010-09       Impact factor: 2.419

3.  Production design and evaluation of a novel breast phantom with various breast glandular fractions.

Authors:  Tatsuya Fujisaki; Masaya Kimura; Hidetoshi Saitoh; Shinji Abe; Takeshi Hiraoka
Journal:  Radiat Med       Date:  2006-12-25

4.  Comparison of three tissue composition measurement techniques using digital mammograms--a signal-to-noise study.

Authors:  D S Breitenstein; C C Shaw
Journal:  J Digit Imaging       Date:  1998-08       Impact factor: 4.056

5.  Development of a physical 3D anthropomorphic breast phantom.

Authors:  Ann-Katherine Carton; Predrag Bakic; Christer Ullberg; Helen Derand; Andrew D A Maidment
Journal:  Med Phys       Date:  2011-02       Impact factor: 4.071

6.  Metal artefact reduction with cone beam CT: an in vitro study.

Authors:  B B Bechara; W S Moore; C A McMahan; M Noujeim
Journal:  Dentomaxillofac Radiol       Date:  2012-01-12       Impact factor: 2.419

7.  Quantification of technetium-99m lung radioactivity from planar images.

Authors:  N I Forge; P J Mountford; M J O'Doherty
Journal:  Eur J Nucl Med       Date:  1993-01

8.  Fabrication and control of CT number through polymeric composites based on coronary plaque CT phantom applications.

Authors:  Carlton F O Hoy; Hani E Naguib; Narinder Paul
Journal:  J Med Imaging (Bellingham)       Date:  2016-02-18

9.  The effects of x-ray beam hardening on detective quantum efficiency and radiation dose.

Authors:  Molly Donovan Wong; Xizeng Wu; Hong Liu
Journal:  J Xray Sci Technol       Date:  2011       Impact factor: 1.535

10.  The impact of calibration phantom errors on dual-energy digital mammography.

Authors:  Xuanqin Mou; Xi Chen; Lijun Sun; Hengyong Yu; Zhen Ji; Lei Zhang
Journal:  Phys Med Biol       Date:  2008-10-20       Impact factor: 3.609

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.