Literature DB >> 8420777

Quantification of technetium-99m lung radioactivity from planar images.

N I Forge1, P J Mountford, M J O'Doherty.   

Abstract

Six methods of quantifying technetium-99m lung uptake from planar gamma camera images were evaluated. Camera sensitivities, the broad beam attenuation coefficient and build-up factors were derived from suitable phantom measurements. The accuracy of the methods was evaluated by quantifying the lung uptake of 99mTc macroaggregated albumin (MAA) in ten patients and assuming complete trapping by the lung of the known activity of injected MAA particles. Three methods based on published techniques which related the count rate from an image of a lung to that from a lung phantom were the least accurate, producing lung activities which were typically about 70% of the injected activity. Of the other three techniques, the depth-dependent build-up factor method was slightly more accurate than the geometric mean and the depth-independent build-up factor methods, producing average values (+/- SD) of lung activity which were 100% +/- 3%, 106% +/- 3% and 101% +/- 5%, respectively, of the injected activity. To measure lung uptake, all of these latter three methods required an attenuation correction with a flood source transmission scan, and therefore their accuracy was affected by the variation in the activity distribution and attenuation across an image of the thorax.

Entities:  

Mesh:

Substances:

Year:  1993        PMID: 8420777     DOI: 10.1007/bf02261239

Source DB:  PubMed          Journal:  Eur J Nucl Med        ISSN: 0340-6997


  17 in total

1.  Differences in relative efficiency of nebulisers for pentamidine administration.

Authors:  M J O'Doherty; S Thomas; C Page; D Barlow; C Bradbeer; T O Nunan; N T Bateman
Journal:  Lancet       Date:  1988-12-03       Impact factor: 79.321

2.  The buildup factor: effect of scatter on absolute volume determination.

Authors:  J A Siegel; R K Wu; A H Maurer
Journal:  J Nucl Med       Date:  1985-04       Impact factor: 10.057

3.  Variability in the measurement of nebulized aerosol deposition in man.

Authors:  S H Thomas; M J O'Doherty; C J Page; T O Nunan
Journal:  Clin Sci (Lond)       Date:  1991-12       Impact factor: 6.124

4.  A technique for the absolute measurement of activity using a gamma camera and computer.

Authors:  J S Fleming
Journal:  Phys Med Biol       Date:  1979-01       Impact factor: 3.609

5.  Efficiency of nebulizers for depositing saline in human lung.

Authors:  T Asmundsson; R F Johnson; K H Kilburn; J K Goodrich
Journal:  Am Rev Respir Dis       Date:  1973-09

6.  Pulmonary deposition of nebulised pentamidine isethionate: effect of nebuliser type, dose, and volume of fill.

Authors:  M O'Doherty; S Thomas; C Page; C Bradbeer; T Nunan; N Bateman
Journal:  Thorax       Date:  1990-06       Impact factor: 9.139

7.  Absolute quantitation of radiotracer uptake in the lungs using a gamma camera.

Authors:  D J Macey; R Marshall
Journal:  J Nucl Med       Date:  1982-08       Impact factor: 10.057

8.  Tc-99m attenuation coefficients in water-filled phantoms determined with gamma cameras.

Authors:  C C Harris; K L Greer; R J Jaszczak; C E Floyd; E C Fearnow; R E Coleman
Journal:  Med Phys       Date:  1984 Sep-Oct       Impact factor: 4.071

9.  The effect of source size on the buildup factor calculation of absolute volume.

Authors:  J A Siegel
Journal:  J Nucl Med       Date:  1985-11       Impact factor: 10.057

10.  The effects of preferential deposition of histamine in the human airway.

Authors:  R E Ruffin; M B Dolovich; R K Wolff; M T Newhouse
Journal:  Am Rev Respir Dis       Date:  1978-03
View more
  7 in total

Review 1.  Management of acute pediatric asthma.

Authors:  John C Carl; Carolyn M Kercsmar
Journal:  Curr Allergy Asthma Rep       Date:  2002-11       Impact factor: 4.806

Review 2.  Measurement techniques for respiratory tract deposition of airborne nanoparticles: a critical review.

Authors:  Jakob Löndahl; Winfried Möller; Joakim H Pagels; Wolfgang G Kreyling; Erik Swietlicki; Otmar Schmid
Journal:  J Aerosol Med Pulm Drug Deliv       Date:  2013-10-23       Impact factor: 2.849

Review 3.  Internal dosimetry: developments and limitations.

Authors:  P J Mountford
Journal:  Eur J Nucl Med       Date:  1996-05

4.  The estimation of administered activity of krypton-81m for lung ventilation studies.

Authors:  N J Dudley; K Griffith; G P McGill; A T Rogers
Journal:  Eur J Nucl Med       Date:  1995-04

Review 5.  Aerosols for therapy and diagnosis.

Authors:  M J O'Doherty; R F Miller
Journal:  Eur J Nucl Med       Date:  1993-12

Review 6.  Studies using radiolabelled aerosols in children.

Authors:  M L Everard
Journal:  Thorax       Date:  1994-12       Impact factor: 9.139

7.  Pulmonary deposition of aerosolised pentamidine using a new nebuliser: efficiency measurements in vitro and in vivo.

Authors:  P P Ferretti; A Versari; S I Gafà; M H Becquemin; E Barchi; D Serafini; M Roy; D Salvo; A Bouchikhi
Journal:  Eur J Nucl Med       Date:  1994-05
  7 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.