Fabrication and control of CT number through polymeric composites based on coronary plaque CT phantom applications.

Carlton F O Hoy1, Hani E Naguib2, Narinder Paul3.   

Abstract

Biomedical phantoms are commonly used for various medical imaging modalities to improve imaging quality and procedures. Current biomedical phantoms fabricated commercially are high in cost and limited in the specificity of human environments and structures that can be mimicked. This study aimed to control the measurable computed tomography (CT) number in Hounsfield units through polymeric biomedical phantom materials using controlled amounts of hydroxyapatite (hA). The purpose was to fabricate CT phantoms capable of mimicking various coronary plaque types while introducing a fabrication technique and basis for a numerical model to which the technique may be applied. The CT number is tunable based on the controlled material properties of electron density and atomic numbers. Three different polymeric matrices of polyethylene (PE), thermoplastic polyurethane (TPU), and polyvinylidene fluoride (PVDF) were selected due to their varied specific densities and ease of fabrication acting as integral properties for CT phantom fabrication. These polymers were processed together with additions of hA in mass percentages of 2.5, 5, 10, and 20% hA as well as a 0% hA as a control for each polymeric material. By adding hA to PE, TPU, and PVDF an increasing trend was exhibited between CT number and weight percent of hA.

Entities:  

Keywords:  attenuation; computed tomography; image analysis; microfabrication; polymer; tissues

Year:  2016        PMID: 26958580      PMCID: PMC4757749          DOI: 10.1117/1.JMI.3.1.016001

Source DB:  PubMed          Journal:  J Med Imaging (Bellingham)        ISSN: 2329-4302


  26 in total

Review 1.  X-ray-based attenuation correction for positron emission tomography/computed tomography scanners.

Authors:  Paul E Kinahan; Bruce H Hasegawa; Thomas Beyer
Journal:  Semin Nucl Med       Date:  2003-07       Impact factor: 4.446

2.  Computed tomographic attenuation value of coronary atherosclerotic plaques with different tube voltage: an ex vivo study.

Authors:  Yutaka Tanami; Eiji Ikeda; Masahiro Jinzaki; Kozo Satoh; Yuji Nishiwaki; Minoru Yamada; Yasunori Okada; Sachio Kuribayashi
Journal:  J Comput Assist Tomogr       Date:  2010-01       Impact factor: 1.826

3.  Quantification of arterial plaque and lumen density with MDCT.

Authors:  Narinder S Paul; Joerg Blobel; Hany Kashani; Murray Rice; Ali Ursani
Journal:  Med Phys       Date:  2010-08       Impact factor: 4.071

4.  In vitro measurement of CT density and estimation of stenosis related to coronary soft plaque at 100 kV and 120 kV on ECG-triggered scan.

Authors:  Jun Horiguchi; Chikako Fujioka; Masao Kiguchi; Hideya Yamamoto; Yun Shen; Yasuki Kihara
Journal:  Eur J Radiol       Date:  2009-08-27       Impact factor: 3.528

5.  Hydroxyapatite-reinforced polyethylene as an analogous material for bone replacement.

Authors:  W Bonfield
Journal:  Ann N Y Acad Sci       Date:  1988       Impact factor: 5.691

6.  Acceptance testing computerized radiation therapy treatment planning systems: direct utilization of CT scan data.

Authors:  E C McCullough; T W Holmes
Journal:  Med Phys       Date:  1985 Mar-Apr       Impact factor: 4.071

7.  Accuracy of CT-based attenuation correction in PET/CT bone imaging.

Authors:  Monica Abella; Adam M Alessio; David A Mankoff; Lawrence R MacDonald; Juan Jose Vaquero; Manuel Desco; Paul E Kinahan
Journal:  Phys Med Biol       Date:  2012-04-05       Impact factor: 3.609

8.  Impact of luminal density on plaque classification by CT coronary angiography.

Authors:  Maiken Glud Dalager; Morten Bøttcher; Gratien Andersen; Jesper Thygesen; Erik Morre Pedersen; Lone Dejbjerg; Ole Gøtzsche; Hans Erik Bøtker
Journal:  Int J Cardiovasc Imaging       Date:  2010-09-05       Impact factor: 2.357

9.  In vitro response of osteoblasts to hydroxyapatite-reinforced polyethylene composites.

Authors:  L Di Silvio; M Dalby; W Bonfield
Journal:  J Mater Sci Mater Med       Date:  1998-12       Impact factor: 3.896

10.  High-definition computed tomography for coronary artery stent imaging: a phantom study.

Authors:  Wen Jie Yang; Ke Min Chen; Li Fang Pang; Ying Guo; Jian Ying Li; Huang Zhang; Zi Lai Pan
Journal:  Korean J Radiol       Date:  2011-12-23       Impact factor: 3.500

View more
  2 in total

1.  Image registration assessment in radiotherapy image guidance based on control chart monitoring.

Authors:  Wenyao Xia; Stephen L Breen
Journal:  J Med Imaging (Bellingham)       Date:  2018-03-14

2.  Evaluation of Radiation Shielding Properties of the Polyvinyl Alcohol/Iron Oxide Polymer Composite.

Authors:  K Srinivasan; E James Jabaseelan Samuel
Journal:  J Med Phys       Date:  2017 Oct-Dec
  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.