Literature DB >> 547966

Instability and wear of total hip prostheses determined with roentgen stereophotogrammetry.

H Baldursson, N Egund, L I Hansson, G Selvik.   

Abstract

A roentgen stereophotogrammetric analysis of hip prostheses was made in four patients with rheumatoid arthritis during a postoperative period of 2 years. Implanted tantalum balls, prosthetic femoral head, and ends of the wire in the acetabular socket were used as measurement points. The migration of the prosthetic head and the acetabular socket in relation to the pelvic bone was determined. The difference between the cranial migration of the head and the socket is a measure of the postoperative instability of the hip joint and deformation of the prosthetic components. This deformation occurs in the plastic acetabular socket and is mainly due to wear. The roentgen stereophotogrammetric method can be applied to standard hip orostheses with a metal femoral head and a plastic or metal acetabular socket to study migration or loosening of the prosthesis in relation to the supporting bone, prosthesis instability, and deformation of the prosthetic components.

Entities:  

Mesh:

Substances:

Year:  1979        PMID: 547966     DOI: 10.1007/BF00389695

Source DB:  PubMed          Journal:  Arch Orthop Trauma Surg        ISSN: 0344-8444


  10 in total

Review 1.  Roentgen stereophotogrammetry. A method for the study of the kinematics of the skeletal system.

Authors:  G Selvik
Journal:  Acta Orthop Scand Suppl       Date:  1989

2.  Can wear in total hip arthroplasties be assessed from radiographs?

Authors:  J C Clarke; K Black; C Rennie; H C Amstutz
Journal:  Clin Orthop Relat Res       Date:  1976 Nov-Dec       Impact factor: 4.176

3.  An instrument for insertion of radiopaque bone markers.

Authors:  A S Aronson; L Hoist; G Selvik
Journal:  Radiology       Date:  1974-12       Impact factor: 11.105

4.  Variables affecting the friction and wear of metal-on-plastic total hip joints.

Authors:  B L Gold; P S Walker
Journal:  Clin Orthop Relat Res       Date:  1974-05       Impact factor: 4.176

5.  The nine and ten year results of the low-friction arthroplasty of the hip.

Authors:  J Charnley; Z Cupic
Journal:  Clin Orthop Relat Res       Date:  1973-09       Impact factor: 4.176

6.  The characteristics of acetabular cups worn in the human body.

Authors:  J M Dowling; J R Atkinson; D Dowson; J Charnley
Journal:  J Bone Joint Surg Br       Date:  1978-08

7.  [Diagnosis for the localization of cemented intramedullar stem prostheses and ICLH-prostheses of the hip by means of stereo X-ray prints (author's transl)].

Authors:  K J Probst; A Herp; W Leidel
Journal:  Arch Orthop Trauma Surg       Date:  1978-08-11

8.  Migration of the acetabular socket after total hip replacement determined by roentgen stereophotogrammetry.

Authors:  H Baldursson; L I Hansson; T H Olsson; G Selvik
Journal:  Acta Orthop Scand       Date:  1980-06

9.  A roentgen stereophotogrammetric investigation of innominate osteotomy (Salter).

Authors:  L I Hansson; T H Olsson; G Selvik; G Sundén
Journal:  Acta Orthop Scand       Date:  1978-02

10.  Hip replacement with the McKee-Farrar prosthesis in rheumatoid arthritis.

Authors:  H Baldursson
Journal:  Acta Orthop Scand       Date:  1980-08
  10 in total
  5 in total

1.  Early Subsidence Predicts Failure of a Cemented Femoral Stem With Minor Design Changes.

Authors:  Per-Erik Johanson; Martin Antonsson; Bita Shareghi; Johan Kärrholm
Journal:  Clin Orthop Relat Res       Date:  2016-10       Impact factor: 4.176

2.  The potential of computed tomography in visualising structures inside the metal cup in surface-replacement total hip arthroplasty.

Authors:  N Egund; H Pettersson; S Frost; L Lidgren
Journal:  Skeletal Radiol       Date:  1987       Impact factor: 2.199

Review 3.  Radiographic assessment of the cup orientation after total hip arthroplasty: a literature review.

Authors:  Jing-Xin Zhao; Xiu-Yun Su; Zhe Zhao; Ruo-Xiu Xiao; Li-Cheng Zhang; Pei-Fu Tang
Journal:  Ann Transl Med       Date:  2020-02

Review 4.  Wear of highly crosslinked polyethylene acetabular components.

Authors:  Stuart A Callary; Lucian B Solomon; Oksana T Holubowycz; David G Campbell; Zachary Munn; Donald W Howie
Journal:  Acta Orthop       Date:  2014-10-10       Impact factor: 3.717

5.  A new automated way to measure polyethylene wear in THA using a high resolution CT scanner: method and analysis.

Authors:  Gerald Q Maguire; Marilyn E Noz; Henrik Olivecrona; Michael P Zeleznik; Lars Weidenhielm
Journal:  ScientificWorldJournal       Date:  2014-01-22
  5 in total