Roentgen stereophotogrammetry. A method for the study of the kinematics of the skeletal system.

G Selvik1.   

Abstract

I have developed a roentgen stereophotogrammetric method for determination of positions of radiopaque markers in an object. The space coordinates are determined in a laboratory coordinate system, which is defined by markers in a test "cage". The markers in the test cage function as calibration points, and are roentgenographed on the same film(s) as the object. Calibration markers and object markers are exposed from two roentgen foci. The cage markers, are in their function, of two kinds, of which one (fiducial marks) is used for projective transformations of the image points to the laboratory coordinate system, while the other (control points) is used for determining the roentgen foci positions in the same coordinate system. After these calculations have been performed, the three-dimensional coordinates of object indicators are determined by crossing of lines between the roentgen foci and the transformed image points. The mathematical principles for the reconstruction of the bundles of rays from the roentgen foci at the moment of exposure are discussed in Chapter 2. Three constructions of test cages, Models 1A and 1B, and Model 2 are also discussed there. In Test Cage Model 1, the two exposures of the object are obtained on one film, but in Model 2 we expose on two films that are perpendicular to each other. The three cage models are, in turn, intended for high-accuracy determinations of lengths (Model 1A), general determinations of space coordinates, especially in larger objects (Model 1B), and high-accuracy determinations of space coordinates in medium-sized objects (Model 1B), and high-accuracy determinations of space coordinates in medium-sized objects (Model 1B). Note, that if the positions of the roentgen foci and the film are not altered, we can roentgenograph the calibration points separately on a film, and then, after removal of the test cage, roentgenograph the object on the same film. The calibration of the test cages is discussed in Chapter 3. To determine coordinates of markers in a plane is easy, if a rectangular coordinatograph is accessible, and we use the same instrument as for the measurements of the films, a Wild Autograph A8. Determination of the position in space of the plate with control points in relation to the plate with fiducial marks requires more consideration. We describe how the degrees of freedom of the plate with control points (translations in x- and y-directions, rotation angle phi about a z-axis), which are difficult to control at construction of the test cages, can be determined by specific calibration procedures.(ABSTRACT TRUNCATED AT 400 WORDS)

Entities:  

Mesh:

Year:  1989        PMID: 2686344

Source DB:  PubMed          Journal:  Acta Orthop Scand Suppl        ISSN: 0300-8827


  103 in total

1.  The effects of different weight-bearing regimes on press-fit cup stability: a randomised study with five years of follow-up using radiostereometry.

Authors:  Olof Wolf; Per Mattsson; Jan Milbrink; Sune Larsson; Hans Mallmin
Journal:  Int Orthop       Date:  2011-12-07       Impact factor: 3.075

2.  Three-dimensional point localisation in low-dose X-ray images using stereo-photogrammetry.

Authors:  T S Douglas; C L Vaughan; S M Wynne
Journal:  Med Biol Eng Comput       Date:  2004-01       Impact factor: 2.602

3.  Subsidence of a cementless femoral component influenced by body weight and body mass index.

Authors:  Christoph Stihsen; Roman Radl; Armin Keshmiri; Peter Rehak; Reinhard Windhager
Journal:  Int Orthop       Date:  2011-11-04       Impact factor: 3.075

4.  Early migration of the cemented tibial component of unicompartmental knee arthroplasty: a radiostereometry study.

Authors:  Andrea Ensini; Paolo Barbadoro; Alberto Leardini; Fabio Catani; Sandro Giannini
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2012-06-04       Impact factor: 4.342

Review 5.  Ten-year results of tibial osteotomy for medial gonarthrosis. The influence of overcorrection.

Authors:  S Odenbring; N Egund; B Hagstedt; J Larsson; A Lindstrand; S Toksvig-Larsen
Journal:  Arch Orthop Trauma Surg       Date:  1991       Impact factor: 3.067

6.  Emerging ideas: soft tissue applications of radiostereometric analysis.

Authors:  Lucian B Solomon; Stuart A Callary
Journal:  Clin Orthop Relat Res       Date:  2010-11-23       Impact factor: 4.176

7.  The influence of metal backing in unicompartmental tibial component fixation. An in vivo roentgen stereophotogrammetric analysis of micromotion.

Authors:  L Ryd; A Lindstrand; A Stenström; G Selvik
Journal:  Arch Orthop Trauma Surg       Date:  1992       Impact factor: 3.067

8.  Comparing precision of distortion-compensated and stereophotogrammetric Roentgen analysis when monitoring fusion in the cervical spine.

Authors:  Gunnar Leivseth; Frode Kolstad; Oystein P Nygaard; Björn Zoega; W Frobin; P Brinckmann
Journal:  Eur Spine J       Date:  2005-09-15       Impact factor: 3.134

9.  Percutaneous epiphysiodesis in the proximal tibia by a single-portal approach: evaluation by radiostereometric analysis.

Authors:  Joachim Horn; Ragnhild Beate Gunderson; Anders Wensaas; Harald Steen
Journal:  J Child Orthop       Date:  2013-06-12       Impact factor: 1.548

10.  Eight plate should not be used for treating leg length discrepancy.

Authors:  Henrik Lauge-Pedersen; Gunnar Hägglund
Journal:  J Child Orthop       Date:  2013-07-03       Impact factor: 1.548

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.