Literature DB >> 3589735

The potential of computed tomography in visualising structures inside the metal cup in surface-replacement total hip arthroplasty.

N Egund, H Pettersson, S Frost, L Lidgren.   

Abstract

Computed tomography (CT) was employed to evaluate the femoral component of the prosthesis in surface-replacement total hip arthroplasty in seven patients suffering from rheumatoid arthritis. Image reconstruction using the high frequency filter resulted in an image of the cement-bone interface inside the cup which allowed the detection of bone resorption. This new application of CT could prove to be a valuable complement to conventional methods in the radiological assessment of metal cup arthroplasties.

Entities:  

Mesh:

Year:  1987        PMID: 3589735     DOI: 10.1007/bf00356953

Source DB:  PubMed          Journal:  Skeletal Radiol        ISSN: 0364-2348            Impact factor:   2.199


  16 in total

1.  Instability and wear of total hip prostheses determined with roentgen stereophotogrammetry.

Authors:  H Baldursson; N Egund; L I Hansson; G Selvik
Journal:  Arch Orthop Trauma Surg       Date:  1979

2.  Radiologic and clinical evaluation of Harrington instrumentation in the injured dorsolumbar spine.

Authors:  K Herrlin; L Ekelund; G Sundén
Journal:  Acta Radiol Diagn (Stockh)       Date:  1983

3.  Radiographic localization of the acetabular component of a hip prosthesis.

Authors:  B Ghelman
Journal:  Radiology       Date:  1979-02       Impact factor: 11.105

4.  Unstable thoracolumbar fractures. A study by CT and conventional roentgenology of the reduction effect of Harrington instrumentation.

Authors:  J Willén; S Lindahl; L Irstam; A Nordwall
Journal:  Spine (Phila Pa 1976)       Date:  1984-03       Impact factor: 3.468

5.  Radiography, radionuclide imaging, and arthrography in the evaluation of total hip and knee replacement.

Authors:  M I Gelman; R E Coleman; P M Stevens; B W Davey
Journal:  Radiology       Date:  1978-09       Impact factor: 11.105

6.  A pattern recognition method for the removal of streaking artifact in computed tomography.

Authors:  R L Morin; D E Raeside
Journal:  Radiology       Date:  1981-10       Impact factor: 11.105

7.  Nonlinear partial volume artifacts in x-ray computed tomography.

Authors:  G H Glover; N J Pelc
Journal:  Med Phys       Date:  1980 May-Jun       Impact factor: 4.071

8.  Radiologic evaluation of the position of the acetabular component of the total hip prosthesis.

Authors:  H Pettersson; C F Gentz; H O Lindberg; A S Carlsson
Journal:  Acta Radiol Diagn (Stockh)       Date:  1982

9.  ICLH double cup arthroplasty.

Authors:  M A Freeman; G W Bradley
Journal:  Orthop Clin North Am       Date:  1982-10       Impact factor: 2.472

10.  Cemented double cup arthroplasty of the hip: a 5 year experience with the ICLH prosthesis.

Authors:  M A Freeman; H U Cameron; G C Brown
Journal:  Clin Orthop Relat Res       Date:  1978 Jul-Aug       Impact factor: 4.176

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.