The characteristics of acetabular cups worn in the human body.

J M Dowling, J R Atkinson, D Dowson, J Charnley.   

Abstract

In laboratory tests, the ultra-high molecular weight polyethylene used for the acetabular cups of Charnley hip prostheses has a very low wear rate against steel. In the body radiographic measurements indicate that the polyethylene wears more rapidly. In order to investigate this higher wear rate, the sockets of acetabular cups removed at post-mortem have been examined using optical and electron microscopy. It has been shown that a socket wears predominantly on its superior part and that this is a direct consequence of the orientation of the cup in the body and the direction of loading of the hip. In the worn region the femoral head in effect bores out a new socket for itself, a process which is visible with the naked eye after approximately eight years. Electron microscopy shows that the predominant wear mechanism is adhesion, but after about eight years the appearance of surface cracks suggests that surface fatigue is taking place in addition to this. Laboratory wear tests have shown that pure surface fatigue is not sufficient to account for the high clinical wear rate. Other deformation processes are suggested and discussed with regard to the higher clinical wear rate.

Entities:  

Mesh:

Substances:

Year:  1978        PMID: 681413     DOI: 10.1302/0301-620X.60B3.681413

Source DB:  PubMed          Journal:  J Bone Joint Surg Br        ISSN: 0301-620X


  6 in total

1.  Wear mode and wear mechanism of retrieved acetabular cups.

Authors:  Kengo Yamamoto; Atsuhiro Imakiire; Toshinori Masaoka; Takaaki Shishido; Tatsuro Mizoue; Ian C Clarke; Hiromu Shoji; Keiichi Kawanabe; Jiro Tamura
Journal:  Int Orthop       Date:  2003-06-21       Impact factor: 3.075

2.  The prediction of polyethylene wear rate and debris morphology produced by microscopic asperities on femoral heads.

Authors:  C M McNie; D C Barton; E Ingham; J L Tipper; J Fisher; M H Stone
Journal:  J Mater Sci Mater Med       Date:  2000-03       Impact factor: 3.896

3.  Instability and wear of total hip prostheses determined with roentgen stereophotogrammetry.

Authors:  H Baldursson; N Egund; L I Hansson; G Selvik
Journal:  Arch Orthop Trauma Surg       Date:  1979

Review 4.  A Review on Biomaterials for Orthopaedic Surgery and Traumatology: From Past to Present.

Authors:  Grzegorz Szczęsny; Mateusz Kopec; Denis J Politis; Zbigniew L Kowalewski; Adam Łazarski; Tomasz Szolc
Journal:  Materials (Basel)       Date:  2022-05-18       Impact factor: 3.748

5.  Influence of head size on the development of metallic wear and on the characteristics of carbon layers in metal-on-metal hip joints.

Authors:  Volker Braunstein; Christoph M Sprecher; Markus A Wimmer; Stefan Milz; Georg Taeger
Journal:  Acta Orthop       Date:  2009-06       Impact factor: 3.717

6.  No functional benefit of larger femoral heads and alternative bearings at 6 months following primary hip replacement.

Authors:  Simon S Jameson; James M Mason; Paul N Baker; Paul J Gregg; David J Deehan; Mike R Reed
Journal:  Acta Orthop       Date:  2014-10-10       Impact factor: 3.717