Migration of the acetabular socket after total hip replacement determined by roentgen stereophotogrammetry.

H Baldursson, L I Hansson, T H Olsson, G Selvik.   

Abstract

UNLABELLED: In order to evaluate the feasibility of a roentgen stereophotogrammetric method for the analysis of the migration pattern of joint prostheses, tantalum balls were implanted into the acetabular socket and the pelvic bone during total hip replacement in four patients with rheumatoid arthritis. During the postoperative period, the migration of the acetabular socket was determined. The observation period varied from 5-24 months. No clinical or radiographic signs of mechanical loosening or infection were noted. All the investigated patients showed a gradual migration of the acetabular socket. The cranial migration measured up to 1.8 mm in 2 years. The migration along the transverse and sagittal axes was less but not constantly directed. The rotatory movements about the three axes varied and measured up to 5.5 degrees in 2 years. The translation and rotation were greatest during the first few months. The results indicate a gradual migration of the acetabular socket in hip arthroplasty in the osteopenic skeleton in rheumatoid arthritis. IN
CONCLUSION: roentgen stereophotogrammetry may prove to be a valuable means of analysing the migration of implanted prostheses and detecting prosthetic loosening, thereby increasing the possibility of early and correct diagnosis and therapy.

Entities:  

Mesh:

Substances:

Year:  1980        PMID: 7446039     DOI: 10.3109/17453678008990837

Source DB:  PubMed          Journal:  Acta Orthop Scand        ISSN: 0001-6470


  4 in total

1.  Micromotion of conventionally cemented all-polyethylene tibial components in total knee replacements. A roentgen stereophotogrammetric analysis of migration and inducible displacement.

Authors:  L Ryd; A Lindstrand; R Rosenquist; G Selvik
Journal:  Arch Orthop Trauma Surg       Date:  1987

2.  Instability and wear of total hip prostheses determined with roentgen stereophotogrammetry.

Authors:  H Baldursson; N Egund; L I Hansson; G Selvik
Journal:  Arch Orthop Trauma Surg       Date:  1979

3.  [Long-term results of 2 uncemented acetabular cup components in total hip prosthesis].

Authors:  D Schmitt; O Bigard; F Bresler; D Molé; P Bernard
Journal:  Int Orthop       Date:  1993-12       Impact factor: 3.075

4.  [Acetabulum without cement. Short-term results of a series of 112 threaded cups].

Authors:  F Gouin; F Fechoz; N Passuti; J Sentucq-Rigal; O Bertrand; J V Bainvel
Journal:  Int Orthop       Date:  1993       Impact factor: 3.075

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.