Literature DB >> 3938477

Capnography and the Bain circuit I: A computer model.

J E Beneken, N Gravenstein, J S Gravenstein, J J van der Aa, S Lampotang.   

Abstract

The Mapleson D anesthesia breathing system has no valves and allows rebreathing of carbon dioxide. Its coaxial version is known as the Bain system. The interpretation of capnograms obtained during its use requires an understanding of the interrelationships of patient and system variables. Toward that end, a systematic description of mechanical ventilation with the Bain circuit was undertaken based on the physical laws of gas transport. The mathematical formulation of the model contains the relations between pressure, flow, and volume in the tube, alveolar space, and ventilator. The flows, calculated from these relations, are used to determine the CO2 concentrations in the different parts of the model. Two sets of data are used--patient and system. The patient data, used to solve the equations numerically, are lung-thorax compliance, CO2 inflow into alveolar space (CO2 production), functional residual capacity, dead space volume, airway resistance, and respiratory quotient. The ventilation system data comprise the dimensions and volumes of the Bain circuit, ventilator, connectors, and tubes; spill valve pressure; resistances to flow in the individual tube parts; ventilator settings; and fresh-gas flow rates. After incorporation of a volunteer's respiratory variables into the model, capnograms obtained from the model compared well with those obtained from the volunteer. The structure of the model is such that it permits easy introduction or changes of patient and system variables to obtain individual results or model specific circumstances. This flexibility makes it a useful tool for understanding the properties of the Bain circuit under a variety of clinical circumstances. The results may be displayed in a number of different ways.

Entities:  

Mesh:

Substances:

Year:  1985        PMID: 3938477     DOI: 10.1007/bf02832197

Source DB:  PubMed          Journal:  J Clin Monit        ISSN: 0748-1977


  12 in total

1.  The Bain anaesthetic system. An assessment during controlled ventilation.

Authors:  J D Henville; A P Adams
Journal:  Anaesthesia       Date:  1976-03       Impact factor: 6.955

2.  Carbon dioxide elimination during spontaneous ventilation with a modified Mapleson D system: studies in a lung model.

Authors:  D K Rose; R J Byrick; A B Froese
Journal:  Can Anaesth Soc J       Date:  1978-09

3.  A streamlined anaesthetic system.

Authors:  J A Bain; W E Spoerel
Journal:  Can Anaesth Soc J       Date:  1972-07

4.  The use of multiple models in cardiovascular system studies: transport and perturbation methods.

Authors:  J E Beneken; V C Rideout
Journal:  IEEE Trans Biomed Eng       Date:  1968-10       Impact factor: 4.538

5.  Rebreathing and end-tidal CO2 during spontaneous breathing with the Bain circuit.

Authors:  W E Spoerel
Journal:  Can Anaesth Soc J       Date:  1983-03

6.  Rebreathing and carbon dioxide elimination with the Bain circuit.

Authors:  W E Spoerel
Journal:  Can Anaesth Soc J       Date:  1980-07

7.  Factors influencing capnography in the Bain circuit.

Authors:  N Gravenstein; S Lampotang; J E Beneken
Journal:  J Clin Monit       Date:  1985-01

8.  The Bain anaesthetic circuit.

Authors:  M E Fryer
Journal:  S Afr Med J       Date:  1978-06-03

9.  Controlled ventilation with the Mapleson D system A theoretical and experimental study.

Authors:  H F Seeley; P K Barnes; C M Conway
Journal:  Br J Anaesth       Date:  1977-02       Impact factor: 9.166

10.  The Lack, Magill and Bain anaesthetic breathing systems: a direct comparison in spontaneously-breathing anaesthetized adults.

Authors:  D Humphrey
Journal:  J R Soc Med       Date:  1982-07       Impact factor: 18.000

View more
  4 in total

1.  A small bypass mixing chamber for monitoring metabolic rate and anesthetic uptake: the bymixer.

Authors:  Y Sanjo; K Ikeda
Journal:  J Clin Monit       Date:  1987-10

2.  Capnography and the Bain circuit II: Validation of a computer model.

Authors:  J E Beneken; N Gravenstein; S Lampotang; J J van der Aa; J S Gravenstein
Journal:  J Clin Monit       Date:  1987-07

3.  A mass balance model for the Mapleson D anaesthesia breathing system.

Authors:  M A Lovich; B A Simon; J G Venegas; N M Sims; J B Cooper
Journal:  Can J Anaesth       Date:  1993-06       Impact factor: 5.063

4.  Reduction of fresh gas flow requirements by a circle-modified bain breathing circuit.

Authors:  J B Valdrighi; P N Nance
Journal:  J Clin Monit       Date:  1991-01
  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.