Literature DB >> 4093790

Factors influencing capnography in the Bain circuit.

N Gravenstein, S Lampotang, J E Beneken.   

Abstract

The Bain circuit provides continuous fresh gas flow near the airway. The potential mixing of this fresh gas with expired gas may prevent reliable analysis of expired gas. We therefore investigated the interaction of sampling site, fresh gas flow rate, expiratory flow rate, and sampling flow rate on expiratory capnography. Sampling near the fresh gas outlet yielded inaccurate results under several of these conditions. The magnitude of the error was related to the fresh gas and expiratory flow rates. A reliable sampling region near the endotracheal tube was identified.

Mesh:

Year:  1985        PMID: 4093790     DOI: 10.1007/BF02832683

Source DB:  PubMed          Journal:  J Clin Monit        ISSN: 0748-1977


  1 in total

1.  Error in sampling of exhaled gases.

Authors:  R F Kaplan; D A Paulus
Journal:  Anesth Analg       Date:  1983-10       Impact factor: 5.108

  1 in total
  17 in total

Review 1.  Capnometry and anaesthesia.

Authors:  K Bhavani-Shankar; H Moseley; A Y Kumar; Y Delph
Journal:  Can J Anaesth       Date:  1992-07       Impact factor: 5.063

2.  Laboratory evaluation of the vital signs (ICOR) piezoelectric anesthetic agent analyzer.

Authors:  D R Westenskow; F H Silva
Journal:  J Clin Monit       Date:  1991-04

3.  A system of classification for the clinical applications of capnography.

Authors:  Naveen Eipe; Jordan Tarshis
Journal:  J Clin Monit Comput       Date:  2007-10-09       Impact factor: 2.502

4.  Accuracy of end-tidal PCO2 measurements using a sidestream capnometer in infants and children ventilated with the Sechrist infant ventilator.

Authors:  S C Hillier; J M Badgwell; M E McLeod; R E Creighton; J Lerman
Journal:  Can J Anaesth       Date:  1990-04       Impact factor: 5.063

5.  The effect of the Bain circuit on gas exchange.

Authors:  M J Jaeger; R R Schultetus
Journal:  Can J Anaesth       Date:  1987-01       Impact factor: 5.063

6.  Dedicated monitoring of anesthetic and respiratory gases by Raman scattering.

Authors:  R A VanWagenen; D R Westenskow; R E Benner; D E Gregonis; D L Coleman
Journal:  J Clin Monit       Date:  1986-10

7.  Single lever Humphrey A.D.E. low flow universal anaesthetic breathing system. Part I: Comparison with dual lever A.D.E., Magill and Bain systems in anaesthetized spontaneously breathing adults.

Authors:  D Humphrey; J G Brock-Utne; J W Downing
Journal:  Can Anaesth Soc J       Date:  1986-11

8.  Can we trust end-tidal carbon dioxide measurements in infants?

Authors:  F J Sasse
Journal:  J Clin Monit       Date:  1985-07

9.  End-tidal PCO2 monitoring via nasal cannulae in pediatric patients: accuracy and sources of error.

Authors:  R H Friesen; M Alswang
Journal:  J Clin Monit       Date:  1996-03

10.  Continuous end-tidal CO2 sampling within the proximal endotracheal tube estimates arterial CO2 tension in infants.

Authors:  G F Rich; J M Sconzo
Journal:  Can J Anaesth       Date:  1991-03       Impact factor: 5.063

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.