The Lack, Magill and Bain anaesthetic breathing systems: a direct comparison in spontaneously-breathing anaesthetized adults.

D Humphrey.   

Abstract

The performances of the Lack (Mapleson A), Magill (Mapleson A) and Bain (Mapleson D) anaesthetic breathing systems were compared in each of 20 anaesthetized adult patients breathing spontaneously with fresh gas flows of 70 ml kg-1 min-1. In every patient the Lack system caused the least rebreathing, as seen by the lowest inspired and end-expired CO2 tensions using capnography. The Magill caused more rebreathing than the Lack though less than the Bain. Comparative fresh gas flows for each system at the point where rebreathing started to occur were examined in 10 further patients. The Lack system required approximately 51 ml kg-1 min-1, the Magill 72 ml kg-1 min-1 while the Bain required 153 ml kg-1 min-1. Of the three systems the Lack is concluded to be the most efficient and economical system for spontaneous respiration in adults, with the additional advantages of convenient access to the exhaust valve, easy scavenging and low expiratory resistance. In addition, it also offers many useful advantages over the circle absorber system.

Entities:  

Mesh:

Substances:

Year:  1982        PMID: 6806473      PMCID: PMC1437895          DOI: 10.1177/014107688207500706

Source DB:  PubMed          Journal:  J R Soc Med        ISSN: 0141-0768            Impact factor:   18.000


  17 in total

Review 1.  Radial artery cannulation.

Authors:  T E Oh; N J Davis
Journal:  Anaesth Intensive Care       Date:  1975-02       Impact factor: 1.669

2.  The Lack anaesthetic system. An assessment during spontaneous ventilation.

Authors:  P K Barnes; H F Seeley; J W Gothard; C M Conway
Journal:  Anaesthesia       Date:  1976-11       Impact factor: 6.955

3.  An experimental study of gaseous homeostasis and the Magill circuit using low fresh gas flows.

Authors:  C M Conway; F M Davis; H J Knight; J M Leigh; T D Preston; R Tennant
Journal:  Br J Anaesth       Date:  1976-05       Impact factor: 9.166

4.  The Bain anaesthetic system. An assessment during controlled ventilation.

Authors:  J D Henville; A P Adams
Journal:  Anaesthesia       Date:  1976-03       Impact factor: 6.955

5.  Theatre pollution control.

Authors:  J A Lack
Journal:  Anaesthesia       Date:  1976-03       Impact factor: 6.955

6.  Performance of the Lack circuit.

Authors:  J Norman; M Nott; F Walters
Journal:  Anaesthesia       Date:  1977 Jul-Aug       Impact factor: 6.955

7.  Spontaneous respiration with the Bain breathing circuit.

Authors:  W E Spoerel; R R Aitken; J A Bain
Journal:  Can Anaesth Soc J       Date:  1978-01

8.  Resistance of Heidbrink-type expiratory valves.

Authors:  M R Nott; J Norman
Journal:  Br J Anaesth       Date:  1978-05       Impact factor: 9.166

9.  A streamlined anaesthetic system.

Authors:  J A Bain; W E Spoerel
Journal:  Can Anaesth Soc J       Date:  1972-07

10.  Spontaneous ventilation with the Bain anaesthetic system.

Authors:  C M Conway; H F Seeley; P K Barnes
Journal:  Br J Anaesth       Date:  1977-12       Impact factor: 9.166

View more
  7 in total

Review 1.  Anaesthesia breathing circuits.

Authors:  J W McIntyre
Journal:  Can Anaesth Soc J       Date:  1986-01

2.  Single lever Humphrey A.D.E. low flow universal anaesthetic breathing system. Part I: Comparison with dual lever A.D.E., Magill and Bain systems in anaesthetized spontaneously breathing adults.

Authors:  D Humphrey; J G Brock-Utne; J W Downing
Journal:  Can Anaesth Soc J       Date:  1986-11

3.  Cost of anaesthesia.

Authors:  D Humphrey; J W Downing; J G Brock-Utne
Journal:  Br Med J (Clin Res Ed)       Date:  1983-03-05

4.  Rebreathing and the Bain circuit.

Authors:  D D Imrie
Journal:  Can Anaesth Soc J       Date:  1983-11

5.  Rebreathing and the Bain circuit.

Authors:  D Humphrey
Journal:  Can Anaesth Soc J       Date:  1984-05

6.  Capnography and the Bain circuit I: A computer model.

Authors:  J E Beneken; N Gravenstein; J S Gravenstein; J J van der Aa; S Lampotang
Journal:  J Clin Monit       Date:  1985-04

7.  Comparative study of minimal fresh gas flow used in Lack-Plus and Lack's circuit in spontaneously breathing anesthetized adults.

Authors:  Sunchai Theerapongpakdee; Thepakorn Sathitkarnmanee; Sirirat Tribuddharat; Siwalai Sucher; Maneerat Thananun; Duangthida Nonlhaopol
Journal:  Med Devices (Auckl)       Date:  2016-11-08
  7 in total