Literature DB >> 937671

The Bain anaesthetic system. An assessment during controlled ventilation.

J D Henville, A P Adams.   

Abstract

The Bain anaesthetic breathing system-a modified Mapleson 'D' circuit10-had been evaluated during anaesthesia using controlled ventilation. Results obtained from over 140 patients show that a highly predictable PaCO2 may be obtained by adjusting the fresh gas inflow according to body weight in patients weighing over 40 kg (mean PaCO2 at a fresh gas inflow of 70 ml/kg/minute=40.8 mmHg; mean PaCO2 at a fresh gas inflow of 100 ml/kg/minute=34.3 mmHg). The circuit is long enough to provide flexibility but may even be doubled in length without affecting performance. Simple lung ventilators delivering air or oxygen may be used satisfactorily as anaesthetic ventilators for patients of all ages. In addition, the circuit is lightweight, disposable but re-usable, facilitates pollution control and is easily used as an independent resuscitator. It is suggested that it may qualify as a universal breathing system.

Entities:  

Mesh:

Substances:

Year:  1976        PMID: 937671     DOI: 10.1111/j.1365-2044.1976.tb11798.x

Source DB:  PubMed          Journal:  Anaesthesia        ISSN: 0003-2409            Impact factor:   6.955


  18 in total

1.  Carbon dioxide output and elimination in children under anaesthesia.

Authors:  J A Bain; W E Spoerel
Journal:  Can Anaesth Soc J       Date:  1977-09

2.  Flow requirements for the Bain breathing circuit during anaesthesia for caesarean section.

Authors:  H S Moseley; K B Shankar; A Krishnan
Journal:  Can Anaesth Soc J       Date:  1986-09

3.  Spontaneous respiration with the Bain breathing circuit.

Authors:  W E Spoerel; R R Aitken; J A Bain
Journal:  Can Anaesth Soc J       Date:  1978-01

4.  Carbon dioxide elimination during spontaneous ventilation with a modified Mapleson D system: studies in a lung model.

Authors:  D K Rose; R J Byrick; A B Froese
Journal:  Can Anaesth Soc J       Date:  1978-09

5.  Normocapnic anaesthesia for intraocular surgery.

Authors:  A P Adams; A Freedman; J D Henville
Journal:  Br J Ophthalmol       Date:  1979-03       Impact factor: 4.638

6.  Anaesthetic waste gas scavenging systems.

Authors:  R J Armstrong; E J Kershaw; S P Bourne; L Strunin
Journal:  Br Med J       Date:  1977-04-09

7.  Cost of anaesthesia.

Authors:  D Humphrey; J W Downing; J G Brock-Utne
Journal:  Br Med J (Clin Res Ed)       Date:  1983-03-05

8.  Rebreathing and carbon dioxide elimination with the Bain circuit.

Authors:  W E Spoerel
Journal:  Can Anaesth Soc J       Date:  1980-07

9.  Rebreathing and co-axial circuits: a comparison of the Bain and MERA F.

Authors:  R J Byrick; E Janssen; M Yamashita
Journal:  Can Anaesth Soc J       Date:  1981-07

10.  Carbon dioxide absorption system with a simple modification of the Bain circuit.

Authors:  K H Rah; N R Lee; M L McDougle; R L Campbell
Journal:  Anesth Prog       Date:  1982 Sep-Oct
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.