Literature DB >> 389946

Clinical evaluation of the MICRO-ID, API 20E, and conventional media systems for identification of Enterobacteriacea.

S C Edberg, B Atkinson, C Chambers, M H Moore, L Palumbo, C F Zorzon, J M Singer.   

Abstract

MICRO-ID (General Diagnostics, Morris Plains, N.J.) is a new kit system designed for the identification of Enterobacteriaceae in 4 h. It consists of 15 biochemical tests of paper disks. Each test is in its own compartment in a molded plastic tray. Only one reagent need be added to the system (2 drops of 20% KOH, which is added to the Voges-Proskauer test). Based on the pattern of positive and negative biochemical test results, a five-digit octal code number is calculated. An identification is derived from a computer-generated identification manual. A study was conducted to compare three systems-the MICRO-ID 4-h and the API 20E (Analytab Products Inc., Plainview, N.Y.) 18- to 24-h systems and a conventional media system-to measure the ability of each to identify members of the family Enterobacteriaceae. Comparison tables, rather than simple percentage agreement tables, were generated to define the particular strengths and weaknesses of each system and allow the laboratory to best use the data. The MICRO-ID compared quite favorably with conventional media. MICRO-ID yielded incorrect identifications with 1.5% of the isolates tested (API 20E, 4.7% misidentification rate). Half the MICRO-ID misidentifications occurred when the system identified a Citrobacter diversus as a lysine-negative Escherichia coli; all gave one octal number. A direct comparison of the MICRO-ID and API 20E was of limited value because percentage agreements were merely the sums of the errors of each. The ease of inoculation, the requirement for the addition of only one reagent, and the 4-h capability make the MICRO-ID system an extremely attractive development in the field of bacterial identification.

Entities:  

Mesh:

Substances:

Year:  1979        PMID: 389946      PMCID: PMC273121          DOI: 10.1128/jcm.10.2.161-167.1979

Source DB:  PubMed          Journal:  J Clin Microbiol        ISSN: 0095-1137            Impact factor:   5.948


  4 in total

1.  Evaluation of the pathotec Rapid I-D system for identification of Enterobacteriaceae.

Authors:  P B Smith; D L Rhoden; K M Tomfohrde
Journal:  J Clin Microbiol       Date:  1975-04       Impact factor: 5.948

2.  API system: a multitube micromethod for identification of Enterobacteriaceae.

Authors:  P B Smith; K M Tomfohrde; D L Rhoden; A Balows
Journal:  Appl Microbiol       Date:  1972-09

3.  Evaluation of five test-kits-API, AuxoTab, Enterotube, PathoTec and R-B-for identification of Enterobacteriaceae.

Authors:  C E Nord; A A Lindberg; A Dahlbäck
Journal:  Med Microbiol Immunol       Date:  1974-03-22       Impact factor: 3.402

4.  Comparison of micro-ID, API 20E, and conventional media systems in identification of Enterobacteriaceae.

Authors:  K E Aldridge; B B Gardner; S J Clark; J M Matsen
Journal:  J Clin Microbiol       Date:  1978-06       Impact factor: 5.948

  4 in total
  33 in total

1.  Enterosistem 18-R: description and comparative evaluation with conventional methods for identification of members of the family Enterobacteriaceae.

Authors:  R Piccolomini; A Di Girolamo; G Catamo; L Cellini; N Allocati; G Ravagnan
Journal:  J Clin Microbiol       Date:  1991-10       Impact factor: 5.948

2.  Evaluation of the Autoanalysis Colilert test for detection and enumeration of total coliforms.

Authors:  T C Covert; L C Shadix; E W Rice; J R Haines; R W Freyberg
Journal:  Appl Environ Microbiol       Date:  1989-10       Impact factor: 4.792

3.  Comparison of the Quantum II Bacterial Identification System and the AutoMicrobic System for the identification of gram-negative bacilli.

Authors:  M A Pfaller; M J Bale; K R Schulte; F P Koontz
Journal:  J Clin Microbiol       Date:  1986-01       Impact factor: 5.948

4.  Supplementary rapid biochemical test panel for the API 20E bacterial identification system.

Authors:  R C Edinger; P C Migneault; F S Nolte
Journal:  J Clin Microbiol       Date:  1985-12       Impact factor: 5.948

5.  Four hour identification of Enterobacteriaceae with the API Rapid 20E and Micro-ID systems.

Authors:  B Holmes; P S Humphry
Journal:  J Clin Pathol       Date:  1985-10       Impact factor: 3.411

6.  Comparison of the API rapid E four-hour system with the API 20E overnight system for the identification of routine clinical isolates of the family Enterobacteriaceae.

Authors:  T L Overman; D Plumley; S B Overman; N L Goodman
Journal:  J Clin Microbiol       Date:  1985-04       Impact factor: 5.948

7.  Evaluation of the four-hour rapid 20E system for identification of members of the family Enterobacteriaceae.

Authors:  D Izard; M O Husson; P Vincent; H Leclerc; D Monget; J M Boeufgras
Journal:  J Clin Microbiol       Date:  1984-07       Impact factor: 5.948

8.  Use of the automicrobic and enteric-tek systems for identification of Enterobacteriaceae.

Authors:  J Goldstein; J J Guarneri; P Della-Latta; J Scherer
Journal:  J Clin Microbiol       Date:  1982-04       Impact factor: 5.948

9.  Comparison of micro-ID and API 20E in rapid identification of Enterobacteriaceae.

Authors:  W M Gooch; G A Hill
Journal:  J Clin Microbiol       Date:  1982-05       Impact factor: 5.948

10.  Evaluation of Gram-stain screen and Micro-ID methods for direct identification of Enterobacteriaceae from urines.

Authors:  P C Appelbaum; C C Olmstead
Journal:  Med Microbiol Immunol       Date:  1982       Impact factor: 3.402