Literature DB >> 3818232

Optimizing electrocardiograph electrode placement for cardiac-gated magnetic resonance imaging.

R N Dimick, L W Hedlund, R J Herfkens, E K Fram, J Utz.   

Abstract

Electrocardiographs recorded in a magnetic field for cardiac-gating in magnetic resonance imaging (MRI) are complicated by blood flow-induced potentials. This study examines which lead of the standard 12-lead ECG maximizes the QRS while minimizing flow-induced interference. Twelve-lead ECGs were performed on normal volunteers (n = 9) and patients (n = 13) in and out of the bore of a 1.5 Tesla imaging magnet. The amplitude of the major flow-induced potentials was measured, and the vectors of largest induced potential and the QRS axis were plotted for each subject. ECGs obtained outside and inside the magnet were digitized and subtracted (in magnet ECG--out of magnet ECG = artifact ECG) and the peaks of the resultant curves measured. Superimposed potentials were largest in the early T wave and late S-T segment in leads I, II, V1, and V2, and smallest in III and AVF. A low-amplitude 7-to 10-Hz signal occurred in most leads. In the frontal plane, QRS axes and flow potential vectors were closely clustered. In the transverse plane, QRS axes generally followed leads V5 or V6, whereas the flow potential vectors followed leads V1, V2, or V3. The normal and patient groups did not differ. Although leads III and AVP showed the smallest superimposed potentials, V5, V6, or a left posterior chest lead may maximize QRS and reduce artifact most consistently. A 7- to 10-Hz frequency filter may help eliminate artifacts in some subjects.

Entities:  

Mesh:

Year:  1987        PMID: 3818232     DOI: 10.1097/00004424-198701000-00002

Source DB:  PubMed          Journal:  Invest Radiol        ISSN: 0020-9996            Impact factor:   6.016


  17 in total

1.  The seismocardiogram as magnetic-field-compatible alternative to the electrocardiogram for cardiac stress monitoring.

Authors:  M Jerosch-Herold; J Zanetti; H Merkle; L Poliac; H Huang; A Mansoor; F Zhao; N Wilke
Journal:  Int J Card Imaging       Date:  1999-12

2.  Self-gated cardiac cine MRI.

Authors:  Andrew C Larson; Richard D White; Gerhard Laub; Elliot R McVeigh; Debiao Li; Orlando P Simonetti
Journal:  Magn Reson Med       Date:  2004-01       Impact factor: 4.668

Review 3.  Cardiac MRI for clinicians: an overview.

Authors:  A J Duerinckx
Journal:  Int J Cardiovasc Imaging       Date:  2001-12       Impact factor: 2.357

4.  Self-gated PROPELLER-encoded cine cardiac imaging.

Authors:  Chi-Chung Wang; Teng-Yi Huang
Journal:  Int J Cardiovasc Imaging       Date:  2011-11-01       Impact factor: 2.357

5.  Extraction of the magnetohydrodynamic blood flow potential from the surface electrocardiogram in magnetic resonance imaging.

Authors:  Grace M Nijm; Steven Swiryn; Andrew C Larson; Alan V Sahakian
Journal:  Med Biol Eng Comput       Date:  2008-02-01       Impact factor: 2.602

6.  Non-ECG-gated myocardial perfusion MRI using continuous magnetization-driven radial sampling.

Authors:  Behzad Sharif; Rohan Dharmakumar; Reza Arsanjani; Louise Thomson; C Noel Bairey Merz; Daniel S Berman; Debiao Li
Journal:  Magn Reson Med       Date:  2014-01-17       Impact factor: 4.668

Review 7.  Cardiac magnetic resonance imaging and its electrocardiographs (ECG): tips and tricks.

Authors:  Marcelo Souto Nacif; Anna Zavodni; Nadine Kawel; Eui-Young Choi; João A C Lima; David A Bluemke
Journal:  Int J Cardiovasc Imaging       Date:  2011-10-28       Impact factor: 2.357

8.  Physiological Recording in the MRI Environment (PRiME): MRI-Compatible Hemodynamic Recording System.

Authors:  John W Kakareka; Anthony Z Faranesh; Randall H Pursley; Adrienne Campbell-Washburn; Daniel A Herzka; Toby Rogers; Josh Kanter; Kanishka Ratnayaka; Robert J Lederman; Thomas J Pohida
Journal:  IEEE J Transl Eng Health Med       Date:  2018-03-01       Impact factor: 3.316

9.  Self-gated 4D multiphase, steady-state imaging with contrast enhancement (MUSIC) using rotating cartesian K-space (ROCK): Validation in children with congenital heart disease.

Authors:  Fei Han; Ziwu Zhou; Eric Han; Yu Gao; Kim-Lien Nguyen; J Paul Finn; Peng Hu
Journal:  Magn Reson Med       Date:  2016-08-16       Impact factor: 4.668

10.  A 1.5T MRI-conditional 12-lead electrocardiogram for MRI and intra-MR intervention.

Authors:  Zion Tsz Ho Tse; Charles L Dumoulin; Gari D Clifford; Jeff Schweitzer; Lei Qin; Julien Oster; Michael Jerosch-Herold; Raymond Y Kwong; Gregory Michaud; William G Stevenson; Ehud J Schmidt
Journal:  Magn Reson Med       Date:  2014-03       Impact factor: 4.668

View more