Literature DB >> 18239947

Extraction of the magnetohydrodynamic blood flow potential from the surface electrocardiogram in magnetic resonance imaging.

Grace M Nijm1, Steven Swiryn, Andrew C Larson, Alan V Sahakian.   

Abstract

The magnetohydrodynamic effect generates voltages related to blood flow, which are superimposed on the electrocardiogram (ECG) used for gating during cardiac magnetic resonance imaging (MRI). A method is presented for extracting the magnetohydrodynamic signal from the ECG. The extracted magnetohydrodynamic blood flow potential may be physiologically meaningful due to its relationship to blood flow. Removal of the magnetohydrodynamic voltages from the ECG can potentially lead to improved gating and diagnostically useful ECGs.

Mesh:

Year:  2008        PMID: 18239947     DOI: 10.1007/s11517-008-0307-1

Source DB:  PubMed          Journal:  Med Biol Eng Comput        ISSN: 0140-0118            Impact factor:   2.602


  10 in total

1.  Novel real-time R-wave detection algorithm based on the vectorcardiogram for accurate gated magnetic resonance acquisitions.

Authors:  S E Fischer; S A Wickline; C H Lorenz
Journal:  Magn Reson Med       Date:  1999-08       Impact factor: 4.668

2.  Self-gated cardiac cine MRI.

Authors:  Andrew C Larson; Richard D White; Gerhard Laub; Elliot R McVeigh; Debiao Li; Orlando P Simonetti
Journal:  Magn Reson Med       Date:  2004-01       Impact factor: 4.668

3.  Magnetically induced electric fields and currents in the circulatory system.

Authors:  Thomas S Tenforde
Journal:  Prog Biophys Mol Biol       Date:  2005 Feb-Apr       Impact factor: 3.667

Review 4.  MRI of the heart: promises fulfilled?

Authors:  Srikanth Sola; Richard D White; Milind Desai
Journal:  Cleve Clin J Med       Date:  2006-07       Impact factor: 2.321

5.  A real-time QRS detection algorithm.

Authors:  J Pan; W J Tompkins
Journal:  IEEE Trans Biomed Eng       Date:  1985-03       Impact factor: 4.538

6.  Cardiovascular alterations in Macaca monkeys exposed to stationary magnetic fields: experimental observations and theoretical analysis.

Authors:  T S Tenforde; C T Gaffey; B R Moyer; T F Budinger
Journal:  Bioelectromagnetics       Date:  1983       Impact factor: 2.010

7.  Observation of blood flow E.M.F. in externally applied strong magnetic field by surface electrodes.

Authors:  T Togawa; O Okai; M Oshima
Journal:  Med Biol Eng       Date:  1967-03

8.  Computer detection of atrioventricular dissociation from surface electrocardiograms during wide QRS complex tachycardias.

Authors:  J Slocum; E Byrom; L McCarthy; A Sahakian; S Swiryn
Journal:  Circulation       Date:  1985-11       Impact factor: 29.690

9.  Automated rectilinear self-gated cardiac cine imaging.

Authors:  Mark E Crowe; Andrew C Larson; Qiang Zhang; James Carr; Richard D White; Debiao Li; Orlando P Simonetti
Journal:  Magn Reson Med       Date:  2004-10       Impact factor: 4.668

10.  Optimizing electrocardiograph electrode placement for cardiac-gated magnetic resonance imaging.

Authors:  R N Dimick; L W Hedlund; R J Herfkens; E K Fram; J Utz
Journal:  Invest Radiol       Date:  1987-01       Impact factor: 6.016

  10 in total
  13 in total

1.  Self-gating MR imaging of the fetal heart: comparison with real cardiac triggering.

Authors:  Jin Yamamura; Michael Frisch; Hannes Ecker; Joachim Graessner; Kurt Hecher; Gerhard Adam; Ulrike Wedegärtner
Journal:  Eur Radiol       Date:  2010-07-30       Impact factor: 5.315

2.  Adaptive removal of gradients-induced artefacts on ECG in MRI: a performance analysis of RLS filtering.

Authors:  Mario Sansone; Luciano Mirarchi; Marcello Bracale
Journal:  Med Biol Eng Comput       Date:  2010-03-18       Impact factor: 2.602

3.  Magnetic field threshold for accurate electrocardiography in the MRI environment.

Authors:  Mihaela Jekic; Yu Ding; Roger Dzwonczyk; Patrick Burns; Subha V Raman; Orlando P Simonetti
Journal:  Magn Reson Med       Date:  2010-12       Impact factor: 4.668

4.  The Magnetohydrodynamic Effect and its Associated Material Designs for Biomedical Applications: A State-of-the-Art Review.

Authors:  T Stan Gregory; Rui Cheng; Guoyi Tang; Leidong Mao; Zion Tsz Ho Tse
Journal:  Adv Funct Mater       Date:  2016-02-24       Impact factor: 18.808

5.  Magnetic resonance imaging of ionic currents in solution: the effect of magnetohydrodynamic flow.

Authors:  Mukund Balasubramanian; Robert V Mulkern; William M Wells; Padmavathi Sundaram; Darren B Orbach
Journal:  Magn Reson Med       Date:  2014-10-01       Impact factor: 4.668

Review 6.  Imaging modalities for the early diagnosis of acute aortic syndrome.

Authors:  Artur Evangelista; Amelia Carro; Sergio Moral; Gisela Teixido-Tura; José F Rodríguez-Palomares; Hug Cuéllar; David García-Dorado
Journal:  Nat Rev Cardiol       Date:  2013-06-25       Impact factor: 32.419

7.  Adaptive noise cancellation to suppress electrocardiography artifacts during real-time interventional MRI.

Authors:  Vincent Wu; Israel M Barbash; Kanishka Ratnayaka; Christina E Saikus; Merdim Sonmez; Ozgur Kocaturk; Robert J Lederman; Anthony Z Faranesh
Journal:  J Magn Reson Imaging       Date:  2011-05       Impact factor: 4.813

8.  Physiological Recording in the MRI Environment (PRiME): MRI-Compatible Hemodynamic Recording System.

Authors:  John W Kakareka; Anthony Z Faranesh; Randall H Pursley; Adrienne Campbell-Washburn; Daniel A Herzka; Toby Rogers; Josh Kanter; Kanishka Ratnayaka; Robert J Lederman; Thomas J Pohida
Journal:  IEEE J Transl Eng Health Med       Date:  2018-03-01       Impact factor: 3.316

9.  A 1.5T MRI-conditional 12-lead electrocardiogram for MRI and intra-MR intervention.

Authors:  Zion Tsz Ho Tse; Charles L Dumoulin; Gari D Clifford; Jeff Schweitzer; Lei Qin; Julien Oster; Michael Jerosch-Herold; Raymond Y Kwong; Gregory Michaud; William G Stevenson; Ehud J Schmidt
Journal:  Magn Reson Med       Date:  2014-03       Impact factor: 4.668

10.  Comparison of self-gated cine MRI retrospective cardiac synchronization algorithms.

Authors:  Grace M Nijm; Alan V Sahakian; Steven Swiryn; James C Carr; John J Sheehan; Andrew C Larson
Journal:  J Magn Reson Imaging       Date:  2008-09       Impact factor: 4.813

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.