Literature DB >> 3757531

Continuous noninvasive real-time monitoring of stroke volume and cardiac output by thoracic electrical bioimpedance.

D P Bernstein.   

Abstract

Thoracic electrical bioimpedance (TEB) is a noninvasive method for the estimation of left ventricular stroke volume (SV). Objections to TEB in the past have included systematic overestimation of SV and cardiac output in normals, poor correlation in absolute terms with standard cardiac output reference techniques, motion and ventilation artifacts which distorted recorded waveforms except when patients remained in apnea during measurements, and lack of a computer to yield rapid heat-to-beat quantitation of SV and cardiac output. The present study entails real-time, beat-to-beat cardiac output determinations using TEB and assessing its agreement via a digital computer against a reference standard, thermodilution. A correlation coefficient of 0.88 is reported with 85% of data points falling within 20% confidence limits on either side of the line of identity.

Entities:  

Mesh:

Year:  1986        PMID: 3757531     DOI: 10.1097/00003246-198610000-00015

Source DB:  PubMed          Journal:  Crit Care Med        ISSN: 0090-3493            Impact factor:   7.598


  32 in total

1.  A portable instrument for non-invasive monitoring of beat-by-beat cardiovascular haemodynamic parameters based on the volume-compensation and electrical-admittance method.

Authors:  M Nakagawara; K Yamakoshi
Journal:  Med Biol Eng Comput       Date:  2000-01       Impact factor: 2.602

2.  Averaging improves the quality of impedance stroke volume measurements during the head up tilt test.

Authors:  Ye Zhang; Lester A H Critchley; Julian A J H Critchley
Journal:  J Clin Monit Comput       Date:  2002 Apr-May       Impact factor: 2.502

3.  Differential cardiovascular effects of propranolol, atenolol, and pindolol measured by impedance cardiography.

Authors:  S H Thomas; R C Cooper; M Ekwuru; S Fletcher; J Gilbody; T S Husseyin; M Ishaque; R Jagathesan; G Reddy; S E Smith
Journal:  Eur J Clin Pharmacol       Date:  1992       Impact factor: 2.953

4.  Factors influencing the ocular pulse--the heart rate.

Authors:  D R Trew; C B James; S H Thomas; R Sutton; S E Smith
Journal:  Graefes Arch Clin Exp Ophthalmol       Date:  1991       Impact factor: 3.117

5.  Comparison and reproducibility of transthoracic bioimpedance and dual beam Doppler ultrasound measurement of cardiac function in healthy volunteers.

Authors:  H W Ng; T Walley; Y Tsao; A M Breckenridge
Journal:  Br J Clin Pharmacol       Date:  1991-09       Impact factor: 4.335

6.  Multi-channel electrical bioimpedance: a new noninvasive method to simultaneously measure cardiac and peripheral blood flow.

Authors:  Alfred W H Stanley; Jeffery W Herald; Constantine L Athanasuleas; Saji C Jacob; Scott W Sims; Alfred A Bartolucci; Alexander N Tsoglin
Journal:  J Clin Monit Comput       Date:  2007-10-09       Impact factor: 2.502

7.  Bioimpedance versus thermodilution cardiac output measurement: the Bomed NCCOM3 after coronary bypass surgery.

Authors:  A N Thomas; J Ryan; B R Doran; B J Pollard
Journal:  Intensive Care Med       Date:  1991       Impact factor: 17.440

8.  Comparison of impedance cardiography and dye dilution method for measuring cardiac output.

Authors:  W Spiering; P N van Es; P W de Leeuw
Journal:  Heart       Date:  1998-05       Impact factor: 5.994

9.  A comparative evaluation of electrical velocimetry and inert gas rebreathing for the non-invasive assessment of cardiac output.

Authors:  Frederik Trinkmann; Manuel Berger; Ursula Hoffmann; Martin Borggrefe; Jens J Kaden; Joachim Saur
Journal:  Clin Res Cardiol       Date:  2011-07-01       Impact factor: 5.460

10.  Multi-channel electrical bioimpedance: a non-invasive method to simultaneously measure cardiac output and individual arterial limb flow in patients with cardiovascular disease.

Authors:  Alfred W H Stanley; Jeffery W Herald; Constantine L Athanasuleas; Saji C Jacob; Alfred A Bartolucci; Alexander N Tsoglin
Journal:  J Clin Monit Comput       Date:  2009-07-14       Impact factor: 2.502

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.