Estimating statistical uncertainty of Monte Carlo efficiency-gain in the context of a correlated sampling Monte Carlo code for brachytherapy treatment planning with non-normal dose distribution.

Nitai D Mukhopadhyay1, Andrew J Sampson, Daniel Deniz, Gudrun Alm Carlsson, Jeffrey Williamson, Alexandr Malusek.   

Abstract

Correlated sampling Monte Carlo methods can shorten computing times in brachytherapy treatment planning. Monte Carlo efficiency is typically estimated via efficiency gain, defined as the reduction in computing time by correlated sampling relative to conventional Monte Carlo methods when equal statistical uncertainties have been achieved. The determination of the efficiency gain uncertainty arising from random effects, however, is not a straightforward task specially when the error distribution is non-normal. The purpose of this study is to evaluate the applicability of the F distribution and standardized uncertainty propagation methods (widely used in metrology to estimate uncertainty of physical measurements) for predicting confidence intervals about efficiency gain estimates derived from single Monte Carlo runs using fixed-collision correlated sampling in a simplified brachytherapy geometry. A bootstrap based algorithm was used to simulate the probability distribution of the efficiency gain estimates and the shortest 95% confidence interval was estimated from this distribution. It was found that the corresponding relative uncertainty was as large as 37% for this particular problem. The uncertainty propagation framework predicted confidence intervals reasonably well; however its main disadvantage was that uncertainties of input quantities had to be calculated in a separate run via a Monte Carlo method. The F distribution noticeably underestimated the confidence interval. These discrepancies were influenced by several photons with large statistical weights which made extremely large contributions to the scored absorbed dose difference. The mechanism of acquiring high statistical weights in the fixed-collision correlated sampling method was explained and a mitigation strategy was proposed.
Copyright © 2011 Elsevier Ltd. All rights reserved.

Entities:  

Mesh:

Year:  2011        PMID: 21992844      PMCID: PMC3242326          DOI: 10.1016/j.apradiso.2011.09.015

Source DB:  PubMed          Journal:  Appl Radiat Isot        ISSN: 0969-8043            Impact factor:   1.513


  8 in total

1.  Monte Carlo simulation of electron beams from an accelerator head using PENELOPE.

Authors:  J Sempau; A Sánchez-Reyes; F Salvat; H O ben Tahar; S B Jiang; J M Fernández-Varea
Journal:  Phys Med Biol       Date:  2001-04       Impact factor: 3.609

2.  Accelerated Monte Carlo based dose calculations for brachytherapy planning using correlated sampling.

Authors:  Håkan Hedtjärn; Gudrun Alm Carlsson; Jeffrey F Williamson
Journal:  Phys Med Biol       Date:  2002-02-07       Impact factor: 3.609

3.  History by history statistical estimators in the BEAM code system.

Authors:  B R B Walters; I Kawrakow; D W O Rogers
Journal:  Med Phys       Date:  2002-12       Impact factor: 4.071

4.  Monte Carlo evaluation of kerma at a point for photon transport problems.

Authors:  J F Williamson
Journal:  Med Phys       Date:  1987 Jul-Aug       Impact factor: 4.071

5.  Comparison of calculated and measured heterogeneity correction factors for 125I, 137Cs, and 192Ir brachytherapy sources near localized heterogeneities.

Authors:  J F Williamson; H Perera; Z Li; W R Lutz
Journal:  Med Phys       Date:  1993 Jan-Feb       Impact factor: 4.071

6.  Calculation of absorbed dose ratios using correlated Monte Carlo sampling.

Authors:  C M Ma; A E Nahum
Journal:  Med Phys       Date:  1993 Jul-Aug       Impact factor: 4.071

7.  The application of correlated sampling to the computation of electron beam dose distributions in heterogeneous phantoms using the Monte Carlo method.

Authors:  M A Holmes; T R Mackie; W Sohn; P J Reckwerdt; T J Kinsella; A F Bielajew; D W Rogers
Journal:  Phys Med Biol       Date:  1993-06       Impact factor: 3.609

8.  Measurement and calculation of heterogeneity correction factors for an Ir-192 high dose-rate brachytherapy source behind tungsten alloy and steel shields.

Authors:  A S Kirov; J F Williamson; A S Meigooni; Y Zhu
Journal:  Med Phys       Date:  1996-06       Impact factor: 4.071

  8 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.