Literature DB >> 36147418

Comparison of dimensional accuracy of elastomeric impression materials using 3D laser scanner.

Sushil Kar1, Arvind Tripathi2, Juhi Singh3, J Ramkumar4.   

Abstract

Background: The dimensional accuracy of elastomeric impression materials has been evaluated by different methods but their reliability is still questionable. The aim of this study was to evaluate the dimensional accuracy of elastomeric impression material using 3D laser scanner. Method: In the present study, a metal die with its custom tray were designed. Using this die and tray, 10 impressions each were made from addition silicone (Aquasil LV; Dentsply), condensation silicone (Speedex coltene, Whaledent) and polyether (3M; ESPE). All the impressions were poured with Type IV die stone and total of 30 die replicas were obtained. These were scanned with a Picza 3D laser scanner (LPX 600, Roland,California) and the difference between the stone model was calculated by determining its volumetric changes using CAD-CAM pero version 2.0. One way analysis of variance (ANOVA) was used to compare the groups, whereas significance of mean difference between the groups was done by Tukey HSD.
Results: All the three groups showed mean decrease indicating a dimensional shrinkage from the master die. Mean percentage dimensional change in condensation silicone was maximum (-319.02 ±15.50) followed by polyether (-122.59 ± 0.64) and least in addition silicone (-23.83 ± 0.43). All the results were statistically significant (p<0.001).
Conclusion: Picza 3D laser scanner can precisely measure the volumetric changes in all the three elastomeric impression materials.
© 2021 Director General, Armed Forces Medical Services. Published by Elsevier, a division of RELX India Pvt. Ltd.

Entities:  

Keywords:  Elastomeric; Polymerisation; Shrinkage; Silicone

Year:  2021        PMID: 36147418      PMCID: PMC9485857          DOI: 10.1016/j.mjafi.2021.05.019

Source DB:  PubMed          Journal:  Med J Armed Forces India        ISSN: 0377-1237


  11 in total

1.  Accuracy of one-step versus two-step putty wash addition silicone impression technique.

Authors:  S H Hung; J H Purk; D E Tira; J D Eick
Journal:  J Prosthet Dent       Date:  1992-05       Impact factor: 3.426

2.  Factors affecting the accuracy of elastometric impression materials.

Authors:  S Y Chen; W M Liang; F N Chen
Journal:  J Dent       Date:  2004-11       Impact factor: 4.379

3.  Linear dimensional changes in plaster die models using different elastomeric materials.

Authors:  Jefferson Ricardo Pereira; Karina Yumi Murata; Accácio Lins do Valle; Janaina Salomon Ghizoni; Fábio Kenji Shiratori
Journal:  Braz Oral Res       Date:  2010 Jul-Sep

4.  Linear dimensional stability of elastomeric impression materials over time.

Authors:  Analía B Garrofé; Beatriz A Ferrari; Mariana Picca; Andrea E Kaplan
Journal:  Acta Odontol Latinoam       Date:  2011

5.  The effects of different storage conditions on polyether and polyvinylsiloxane impressions.

Authors:  J H Purk; M G Willes; D E Tira; J D Eick; S H Hung
Journal:  J Am Dent Assoc       Date:  1998-07       Impact factor: 3.634

Review 6.  Review of dental impression materials.

Authors:  R G Craig
Journal:  Adv Dent Res       Date:  1988-08

7.  Elastomeric impression materials: a comparison of accuracy of multiple pours.

Authors:  Dheeraj Kumar; Anand U Madihalli; K Rajeev Kumar Reddy; Namrataa Rastogi; N T Pradeep
Journal:  J Contemp Dent Pract       Date:  2011-07-01

8.  Dimensional stability of elastomeric impression materials in custom-made and stock trays.

Authors:  J Valderhaug; F Fløystrand
Journal:  J Prosthet Dent       Date:  1984-10       Impact factor: 3.426

9.  Long-term dimensional stability of three current elastomers.

Authors:  J M Clancy; F R Scandrett; R L Ettinger
Journal:  J Oral Rehabil       Date:  1983-07       Impact factor: 3.837

10.  Accuracy of stone casts obtained by different impression materials.

Authors:  Adriana Cláudia Lapria Faria; Renata Cristina Silveira Rodrigues; Ana Paula Macedo; Maria da Gloria Chiarello de Mattos; Ricardo Faria Ribeiro
Journal:  Braz Oral Res       Date:  2008 Oct-Dec
View more