Literature DB >> 6577158

Long-term dimensional stability of three current elastomers.

J M Clancy, F R Scandrett, R L Ettinger.   

Abstract

The long-term dimensional stability of three non-aqueous elastomeric impression materials, a silicone, a polyether and a polysiloxane, were investigated. The testing apparatus was an A.D.A. specification No. 19 test block and mould. The impressions were measured by the use of a travelling stage reflecting microscope and a Quantimet 720 Image Analyzing computer at time zero and again at 4, 24 and 48 h, and at 1, 2, 3 and 4 weeks. Impressions poured immediately had the greatest accuracy for all the materials. The polysiloxane (0.025 mm) and polyether (0.033 mm) showed very little change in dimension after 4 weeks when compared to the test block. However, the silicone showed significant change at 4 h (0.14 mm) and 0.2 mm after 4 weeks. After 4 weeks the polysiloxane maintained the best surface detail, the polyether was adequate but the silicone lost much of its detail in as little as 24 h. The reasons for these findings are discussed.

Entities:  

Mesh:

Substances:

Year:  1983        PMID: 6577158     DOI: 10.1111/j.1365-2842.1983.tb00127.x

Source DB:  PubMed          Journal:  J Oral Rehabil        ISSN: 0305-182X            Impact factor:   3.837


  6 in total

1.  Marginal and internal fit of four-unit zirconia fixed dental prostheses based on digital and conventional impression techniques.

Authors:  Júnio S Almeida e Silva; Kurt Erdelt; Daniel Edelhoff; Élito Araújo; Michael Stimmelmayr; Luiz Clovis Cardoso Vieira; Jan-Frederik Güth
Journal:  Clin Oral Investig       Date:  2013-05-29       Impact factor: 3.573

2.  Accuracy of full-arch scans using intraoral scanners.

Authors:  Sebastian B M Patzelt; Archontia Emmanouilidi; Susanne Stampf; Joerg R Strub; Wael Att
Journal:  Clin Oral Investig       Date:  2013-11-17       Impact factor: 3.573

3.  Comparison of dimensional accuracy of elastomeric impression materials using 3D laser scanner.

Authors:  Sushil Kar; Arvind Tripathi; Juhi Singh; J Ramkumar
Journal:  Med J Armed Forces India       Date:  2021-07-30

4.  Comparative evaluation of dimensional stability of impression materials from developing countries and developed countries after disinfection with different immersion disinfectant systems and ultraviolet chamber.

Authors:  Rupandeep Kaur Samra; Shreenivas Vasant Bhide
Journal:  Saudi Dent J       Date:  2017-12-13

5.  Three-Dimensional Evaluation on Accuracy of Conventional and Milled Gypsum Models and 3D Printed Photopolymer Models.

Authors:  Jae-Won Choi; Jong-Ju Ahn; Keunbada Son; Jung-Bo Huh
Journal:  Materials (Basel)       Date:  2019-10-25       Impact factor: 3.623

6.  Combining virtual model and cone beam computed tomography to assess periodontal changes after anterior tooth movement.

Authors:  Sun-Hyun Kim; Jong-Bin Lee; Min-Ji Kim; Eun-Kyoung Pang
Journal:  BMC Oral Health       Date:  2018-11-01       Impact factor: 2.757

  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.