Literature DB >> 19148382

Accuracy of stone casts obtained by different impression materials.

Adriana Cláudia Lapria Faria1, Renata Cristina Silveira Rodrigues, Ana Paula Macedo, Maria da Gloria Chiarello de Mattos, Ricardo Faria Ribeiro.   

Abstract

Several impression materials are available in the Brazilian marketplace to be used in oral rehabilitation. The aim of this study was to compare the accuracy of different impression materials used for fixed partial dentures following the manufacturers' instructions. A master model representing a partially edentulous mandibular right hemi-arch segment whose teeth were prepared to receive full crowns was used. Custom trays were prepared with auto-polymerizing acrylic resin and impressions were performed with a dental surveyor, standardizing the path of insertion and removal of the tray. Alginate and elastomeric materials were used and stone casts were obtained after the impressions. For the silicones, impression techniques were also compared. To determine the impression materials' accuracy, digital photographs of the master model and of the stone casts were taken and the discrepancies between them were measured. The data were subjected to analysis of variance and Duncan's complementary test. Polyether and addition silicone following the single-phase technique were statistically different from alginate, condensation silicone and addition silicone following the double-mix technique (p < or = .05), presenting smaller discrepancies. However, condensation silicone was similar (p > or = .05) to alginate and addition silicone following the double-mix technique, but different from polysulfide. The results led to the conclusion that different impression materials and techniques influenced the stone casts' accuracy in a way that polyether, polysulfide and addition silicone following the single-phase technique were more accurate than the other materials.

Entities:  

Mesh:

Substances:

Year:  2008        PMID: 19148382     DOI: 10.1590/s1806-83242008000400002

Source DB:  PubMed          Journal:  Braz Oral Res        ISSN: 1806-8324


  14 in total

1.  Precision of guided scanning procedures for full-arch digital impressions in vivo.

Authors:  Moritz Zimmermann; Christina Koller; Moritz Rumetsch; Andreas Ender; Albert Mehl
Journal:  J Orofac Orthop       Date:  2017-07-21       Impact factor: 1.938

2.  An In-vitro Comparative Stereomicroscopic Analysis and Evaluation of Marginal Accuracy in Porcelain Fused to Metal Copings Fabricated in Two Different Finish Lines Using Variant Die Materials.

Authors:  Priya L Vaswani; Pronob K Sanyal; Siddharth Y Gosavi; Abhijeet R Kore
Journal:  J Clin Diagn Res       Date:  2017-01-01

3.  Randomized controlled clinical trial on the three-dimensional accuracy of fast-set impression materials.

Authors:  Heike Rudolph; Sebastian Quaas; Manuela Haim; Jörg Preißler; Michael H Walter; Rainer Koch; Ralph G Luthardt
Journal:  Clin Oral Investig       Date:  2012-08-31       Impact factor: 3.573

4.  Pilot study on accuracy and dimensional stability of impression materials using industrial CT technology.

Authors:  Stefanie Steinhäuser-Andresen; Andreas Detterbeck; Christoph Funk; Michael Krumm; Stefan Kasperl; Alexandra Holst; Ursula Hirschfelder
Journal:  J Orofac Orthop       Date:  2011-03       Impact factor: 1.938

Review 5.  Digital versus conventional full-arch impressions in linear and 3D accuracy: a systematic review and meta-analysis of in vivo studies.

Authors:  Lin Kong; Yabing Li; Zhijian Liu
Journal:  Clin Oral Investig       Date:  2022-07-04       Impact factor: 3.606

6.  Comparison of dimensional accuracy of elastomeric impression materials using 3D laser scanner.

Authors:  Sushil Kar; Arvind Tripathi; Juhi Singh; J Ramkumar
Journal:  Med J Armed Forces India       Date:  2021-07-30

7.  Digital assessment of properties of the three different generations of dental elastomeric impression materials.

Authors:  Lamia Singer; Shaymaa I Habib; Heba El-Amin Shalaby; Sayed H Saniour; Christoph Bourauel
Journal:  BMC Oral Health       Date:  2022-09-05       Impact factor: 3.747

8.  The effect of pouring time on the dimensional accuracy of casts made from different irreversible hydrocolloid impression materials.

Authors:  Supneet Singh Wadhwa; Richa Mehta; Nidhi Duggal; Kamlesh Vasudeva
Journal:  Contemp Clin Dent       Date:  2013-07

9.  Accuracy and reliability of a novel method for fusion of digital dental casts and Cone Beam Computed Tomography scans.

Authors:  Frits A Rangel; Thomas J J Maal; Ewald M Bronkhorst; K Hero Breuning; Jan G J H Schols; Stefaan J Bergé; Anne Marie Kuijpers-Jagtman
Journal:  PLoS One       Date:  2013-03-20       Impact factor: 3.240

10.  Comparing the Accuracy of Three Different Impression Materials in Making Duplicate Dies.

Authors:  Farshad Bajoghli; Mahmoud Sabouhi; Saeid Nosouhian; Amin Davoudi; Zeynab Behnamnia
Journal:  J Int Oral Health       Date:  2015-07
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.