| Literature DB >> 35974903 |
Adrián Hernández-Martínez1, Miguel A Díaz-Del-Rio1, María Ruiz-Santos1, Ramón Ruiz-Mesa1, Pedro Tañá-Rivero1.
Abstract
Purpose: To evaluate the refractive and visual outcomes following cataract surgery and implantation of a new monofocal non-constant aberration aspheric intraocular lens (IOL).Entities:
Keywords: aberrations; aspheric design; cataract; intraocular lens; phacoemulsification
Year: 2022 PMID: 35974903 PMCID: PMC9376001 DOI: 10.2147/OPTH.S373587
Source DB: PubMed Journal: Clin Ophthalmol ISSN: 1177-5467
Preoperative Demographic Characteristics of Participants Implanted with the CT LUCIA 621P IOL Shown as Means, Standard Deviations (SD) and Ranges
| Parameter | Values |
|---|---|
| 90 | |
| 72.53±7.40 (57 to 88) | |
| 42/44 | |
| 0.18±0.17 (0.01 to 0.70) | |
| 42.80±1.47 (40.02 to 47.62) | |
| 43.62±1.47 (40.68 to 47.87) | |
| 23.38±1.17 (21.41 to 28.46) | |
| 3.14±0.38 (2.35 to 3.88) | |
| 539.1±37.26 (453 to 647) | |
| 4.61±0.40 (3.76 to 5.66) | |
| 12.05±0.42 (10.99 to 13.15) | |
| 22.64±3.44 (6 to 29.50) |
Abbreviations: CDVA, best-corrected distance visual acuity; K, keratometry; IOL, intraocular lens power.
Figure 1Cumulative proportion of eyes having a given uncorrected distance visual acuity (UDVA) and best-corrected distance visual acuity (CDVA) values at 1 month after surgery (efficacy).
Figure 2Change in lines of visual acuity between the postoperative uncorrected distance visual acuity (UDVA) and best-corrected distance visual acuity (CDVA) at 1 month after surgery (efficacy).
Figure 3Histogram of postoperative spherical equivalent refraction (D) at 1 month after surgery (predictability).
Figure 4Histogram of preoperative corneal astigmatism (D) and postoperative refractive astigmatism (D) at 1 month after surgery (predictability).
Main Characteristics of the Different CT LUCIA Models
| IOL Model | CT LUCIA 601P | CT LUCIA 611P | CT LUCIA 621P |
|---|---|---|---|
| Optic Design | Monofocal, aspheric (aberration correcting) | Monofocal, aspheric (aberration correcting) | Monofocal, aspheric (aberration correcting) |
| Material | Hydrophobic acrylic with heparin coated surface | Hydrophobic acrylic with heparin coated surface | Hydrophobic acrylic with heparin coated surface |
| Optic Diameter (mm) | 6 | 6 | 6 |
| Total Diameter (mm) | 13 | 13 | 13 |
| Lens Design | Single-Piece | Single-Piece | Single-Piece |
| Haptic Design | C loop | C loop | C loop |
| Haptic Angulation | 5° angulation | Step vaulted | Step vaulted |
| Incision Size (mm) | 2.2 to 2.6 | 2.2 to 2.6 | 2.2 to 2.6 |
| Diopter Range | 4.0–34.0D | 4.0–34.0D | 0.0–34.0 D |
| Company Labeled A-Constant | 119.1 | 119.9 | 120.2 |
| Implantation in | Capsular bag | Capsular bag | Capsular bag |
| Injector/Cartridge Set | Accuject™ 2.0 Injector Set for diopter range +4.0 to 24.0 D | Blueject™ 2.0 Injector Set for diopter range +4.0 to 24.0 D | BlueSERT™ 2.0 Injector Set for diopter range +0.0 to 24.0 D |
| BlueJect™ 2.2 Injector Set for diopter range +24.5 to 30.0 D | Blueject™ 2.2 Injector Set for diopter range +24.5 to 30.0 D | BlueSERT™ 2.2 Injector Set for diopter range +24.5 to 30.0 D | |
| Blueject™ 2.4 Injector Set for diopter range +30.5 to 34.0 D | Blueject™ 2.4 Injector Set for diopter range +30.5 to 34.0 D | BlueSERT™ 2.4 Injector Set for diopter range +30.5 to 34.0 D | |
| Soft stop | Soft stop | Soft stop | |
| Hard stop | Hard stop | Hard stop |