Literature DB >> 33685428

In-vitro glistening formation in six different foldable hydrophobic intraocular lenses.

Tamer Tandogan1, Gerd U Auffarth2, Hyeck-Soo Son1, Patrick Merz1, Chul Young Choi3, Ramin Khoramnia1.   

Abstract

BACKGROUND: Glistenings describe small, refractile microvacuoles that may arise within the intraocular lens (IOL) material and reduce the patients' quality of vision. Lenses composed of hydrophobic acrylic material are particularly affected by glistening formation. In this study, we compared the tendency of glistening formation in six different types of hydrophobic acrylic intraocular lenses (IOLs).
METHODS: We used a well-established accelerated laboratory method to develop glistenings in the following IOLs: Vivinex XY1 (Hoya), AcrySof SN60WF (Alcon), Tecnis ZCB00 (AMO), Avansee PN6A (Kowa), Aktis SP NS-60YG (Nidek), and CT Lucia 601P (Zeiss). IOLs were first immersed in saline at 45 °C for 24 h and then at 37 °C for 2.5 h in a water bath. Microvacuole (MV) density and size (Miyata grading) were documented and calculated using an image analysis program.
RESULTS: The mean glistening density [MV/mm2] and mean Miyata grading (in brackets) were: Vivinex: 11.6 ± 5.7 (0), SN60WF: 264.4 ± 110.3 (2.6), Tecnis: 6.0 ± 2.8 (0), Avansee: 2.2 ± 0.7 (0), Aktis: 851.4 ± 59.4 (3+) and CT Lucia: 71.0 ± 71.6 (1).
CONCLUSIONS: While all tested IOLs showed glistenings with the accelerated laboratory method, the Aktis and SN60WF showed the highest microvacuole density, followed by the CT Lucia. In comparison, the Vivinex, Tecnis, and Avansee IOLs showed far fewer number of glistenings.

Entities:  

Mesh:

Substances:

Year:  2021        PMID: 33685428      PMCID: PMC7938589          DOI: 10.1186/s12886-021-01879-6

Source DB:  PubMed          Journal:  BMC Ophthalmol        ISSN: 1471-2415            Impact factor:   2.209


  28 in total

1.  Clinical and Experimental Observation of Glistening in Acrylic Intraocular Lenses.

Authors: 
Journal:  Jpn J Ophthalmol       Date:  2000-11-01       Impact factor: 2.447

2.  Visual significance of glistenings seen in the AcrySof intraocular lens.

Authors:  D K Dhaliwal; N Mamalis; R J Olson; A S Crandall; P Zimmerman; O C Alldredge; F J Durcan; O Omar
Journal:  J Cataract Refract Surg       Date:  1996-05       Impact factor: 3.351

3.  In vitro analysis of AcrySof intraocular lens glistenings in AcryPak and Wagon Wheel packaging.

Authors:  O Omar; A Pirayesh; N Mamalis; R J Olson
Journal:  J Cataract Refract Surg       Date:  1998-01       Impact factor: 3.351

4.  Glistenings on intraocular lenses in healthy eyes: effects and associations.

Authors:  Joseph Colin; Isabelle Orignac
Journal:  J Refract Surg       Date:  2011-07-29       Impact factor: 3.573

Review 5.  A review of late intraocular lens opacifications.

Authors:  Piotr Kanclerz; Timur M Yildirim; Ramin Khoramnia
Journal:  Curr Opin Ophthalmol       Date:  2021-01       Impact factor: 3.761

6.  Practice styles and preferences of ASCRS members--2003 survey.

Authors:  David V Leaming
Journal:  J Cataract Refract Surg       Date:  2004-04       Impact factor: 3.351

7.  Glistenings in hydrophobic acrylic intraocular lenses do affect visual function.

Authors:  George Hh Beiko; Andrzej Grzybowski
Journal:  Clin Ophthalmol       Date:  2013-11-27

Review 8.  [Opacification of intraocular lenses: laboratory and clinical findings].

Authors:  Ramin Khoramnia; Timur M Yildirim; Grzegorz Łabuz; Christian S Mayer; Gerd U Auffarth
Journal:  Ophthalmologe       Date:  2020-11-13       Impact factor: 1.059

Review 9.  Clinical properties of a novel, glistening-free, single-piece, hydrophobic acrylic IOL.

Authors:  Mark Packer; Mohan Rajan; Edoardo Ligabue; Peter Heiner
Journal:  Clin Ophthalmol       Date:  2014-02-21

10.  Decreased visual acuity resulting from glistening and sub-surface nano-glistening formation in intraocular lenses: A retrospective analysis of 5 cases.

Authors:  Hiroyuki Matsushima; Mayumi Nagata; Yoko Katsuki; Ichiro Ota; Kensaku Miyake; George H H Beiko; Andrzej Grzybowski
Journal:  Saudi J Ophthalmol       Date:  2015-07-29
View more
  3 in total

Review 1.  Etiology, pathogenesis, and management of acute intraocular lens opacification: a systematic review.

Authors:  Bita Momenaei; Mohammad Reza Akbari; Seyed Ali Tabatabaei; Mohammad Soleimani; Mahdi Soleymanzadeh; Kaveh Fadakar; Ahmed Alshaheeb; Mahtab Malekpour Khazari; Yasaman Vaseghi; Kasra Cheraqpour
Journal:  Int J Ophthalmol       Date:  2022-07-18       Impact factor: 1.645

2.  Refractive and Visual Outcomes of a Monofocal Non-Constant Aberration Aspheric Intraocular Lens.

Authors:  Adrián Hernández-Martínez; Miguel A Díaz-Del-Rio; María Ruiz-Santos; Ramón Ruiz-Mesa; Pedro Tañá-Rivero
Journal:  Clin Ophthalmol       Date:  2022-08-10

3.  Comparative analysis of in vitro accelerated glistening formation in foldable hydrophobic intraocular lenses.

Authors:  Tamer Tandogan; Gerd U Auffarth; Chul Young Choi; Hyeck-Soo Son; Ramin Khoramnia
Journal:  Int Ophthalmol       Date:  2021-05-19       Impact factor: 2.031

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.