Literature DB >> 18978351

In vitro strehl ratios with spherical, aberration-free, average, and customized spherical aberration-correcting intraocular lenses.

Stefan Pieh1, Werner Fiala, Andre Malz, Wilhelm Stork.   

Abstract

PURPOSE: To determine in vitro image qualities of artificial eyes achieved with spherical, aberration-free, average spherical aberration-correcting, and customized spherical aberration-correcting IOLs in centered, decentered, and tilted positions.
METHODS: The in vitro performance of these IOL models was determined by optical bench measurements. The experimental setup included a laser light source controlled by aperture stops that corresponded to 3- and 5-mm pupil apertures, an artificial eye with three alternative corneal models exhibiting low, intermediate, and high spherical aberration (SA), IOLs mounted to an immersed IOL holder that could be moved laterally and tilted, and a charge-coupled device camera and software to determine three-dimensional point spread function (PSF), modulation transfer function, and Strehl ratio.
RESULTS: Differences among the various lens models turned out to be low for a 3-mm pupil. For a pupil aperture of 5 mm, customized IOLs showed the best results for perfect lens positioning. With ongoing decentration and tilt, customized IOLs rapidly lost their advantages, particularly in corneas with high SA and IOLs of high diopters. Spherical IOLs were always inferior to aberration-free IOLs.
CONCLUSIONS: Reasonably well-centered aberration-correcting IOLs may provide considerably better image quality than conventional spherical IOLs. In the presence of significant postoperative decentration and tilt of the IOL, aberration-free IOLs are the safest option among the various intraocular lens designs.

Entities:  

Mesh:

Year:  2008        PMID: 18978351     DOI: 10.1167/iovs.08-2187

Source DB:  PubMed          Journal:  Invest Ophthalmol Vis Sci        ISSN: 0146-0404            Impact factor:   4.799


  20 in total

1.  [Investigation of the theoretical image quality of aspheric intraocular lenses by decentration. Hoya AF-1 iMics1 und Zeiss ASPHINA(TM) (Invent ZO)].

Authors:  M Gillner; A Langenbucher; T Eppig
Journal:  Ophthalmologe       Date:  2012-03       Impact factor: 1.059

2.  Optical performance of toric intraocular lenses in the presence of decentration.

Authors:  Bin Zhang; Jin-Xue Ma; Dan-Yan Liu; Ying-Hua Du; Cong-Rong Guo; Yue-Xian Cui
Journal:  Int J Ophthalmol       Date:  2015-08-18       Impact factor: 1.779

3.  In vitro optical quality comparison between the Mini WELL Ready progressive multifocal and the TECNIS Symfony.

Authors:  Alberto Domínguez-Vicent; Jose Juan Esteve-Taboada; Antonio J Del Águila-Carrasco; Teresa Ferrer-Blasco; Robert Montés-Micó
Journal:  Graefes Arch Clin Exp Ophthalmol       Date:  2015-12-16       Impact factor: 3.117

4.  Optimal incision sites to reduce corneal aberration variations after small incision phacoemulsification cataract surgery.

Authors:  Ling Chu; Jiang-Yue Zhao; Jin-Song Zhang; Jie Meng; Ming-Wu Wang; Ya-Jing Yang; Jia-Ming Yu
Journal:  Int J Ophthalmol       Date:  2016-04-18       Impact factor: 1.779

5.  [Pupil centroid shift: Marketing tool or essential clinical parameter?].

Authors:  I Fischinger; T G Seiler; G Schmidinger; T Seiler
Journal:  Ophthalmologe       Date:  2015-08       Impact factor: 1.059

6.  Repeatability of in-vitro optical quality measurements of intraocular lenses with a deflectometry technique effect of the toricity.

Authors:  Teresa Ferrer-Blasco; Alberto Domínguez-Vicent; Santiago García-Lázaro; María Amparo Díez-Ajenjo; José F Alfonso; José J Esteve-Taboada
Journal:  Int J Ophthalmol       Date:  2018-07-18       Impact factor: 1.779

7.  Objective evaluation of through-focus optical performance of presbyopia-correcting intraocular lenses using an optical bench system.

Authors:  Myoung Joon Kim; Len Zheleznyak; Scott Macrae; Hungwon Tchah; Geunyoung Yoon
Journal:  J Cataract Refract Surg       Date:  2011-07       Impact factor: 3.351

Review 8.  Opto-Mechanical Eye Models, a Review on Human Vision Applications and Perspectives for Use in Industry.

Authors:  André Rino Amorim; Boris Bret; José M González-Méijome
Journal:  Sensors (Basel)       Date:  2022-10-10       Impact factor: 3.847

9.  Tilt and decentration of an intraocular lens implanted in the ciliary sulcus after capsular bag defect during cataract surgery.

Authors:  Thomas Sauer; Ulrich Mester
Journal:  Graefes Arch Clin Exp Ophthalmol       Date:  2012-09-02       Impact factor: 3.117

10.  Effect of Spherical Aberration on the Optical Quality after Implantation of Two Different Aspherical Intraocular Lenses.

Authors:  Michael Lasta; Kata Miháltz; Illés Kovács; Pia Veronika Vécsei-Marlovits
Journal:  J Ophthalmol       Date:  2017-08-16       Impact factor: 1.909

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.