Miguel Á Gil1, Consuelo Varón2, Genis Cardona2, José A Buil1.
Abstract
The objective of this prospective, randomized, double-masked study was to compare the contrast sensitivity and quality of vision of patients bilaterally implanted with the following six different presbyopia correcting intraocular lenses (IOLs): SV25T0 (n = 19), ATLISA 809M (n = 18), ATLISA TRI 839MP (n = 19), ZKB00 (n = 20), ZLB00 (n = 20) and Symfony ZXR00 (n = 20). For comparison purposes, 36 patients were implanted with a monofocal lens (ZA9003). Contrast sensitivity was assessed binocularly at distance under photopic, mesopic and mesopic plus glare conditions, and at near under photopic conditions. Quality of vision was explored in terms of photic phenomena and spectacle independence. Overall, the monofocal lens offered better contrast sensitivity, under all illumination conditions, and less occurrence and intensity of photic phenomena. Amongst the multifocal IOL (MIOL) designs, the extended depth of focus Symfony ZXR00 provided better contrast sensitivity than the other MIOLs, particularly at intermediate and high spatial frequencies. Up to 40% and 50% of patients implanted with MIOLs reported glare and halos, respectively. The SV25T0 resulted in less occurrence and intensity of halos. The evaluation of photic phenomena and contrast sensitivity under different illumination conditions may reflect real-life, visually challenging situations, and thus provide insightful information to assist ophthalmic surgeons when selecting the best intraocular lens for their patients.Entities:
Keywords: cataract surgery; contrast sensitivity; extended depth of focus; multifocal intraocular lens; quality of vision
Year: 2022 PMID: 35887913 PMCID: PMC9316344 DOI: 10.3390/jcm11144150
Source DB: PubMed Journal: J Clin Med ISSN: 2077-0383 Impact factor: 4.964
Intraocular lenses used in the study, base power of 20.00 diopters (D). Near (n) and intermediate (i) add powers correspond to the plane of the lens. Spherical aberration (SA) is for a 6.0 mm pupil.
| LENS | MANUFACTURER | ADD POWER | SA | OPTICAL DESIGN |
|---|---|---|---|---|
| AcrySof ReSTOR SV25T0 | Alcon Laboratories, Fort Worth, TX, USA | +2.5 (n) | −0.20 | Bifocal, anterior aspheric apodized diffractive (3.4 mm) and refractive surface |
| Tecnis ZKB00 | Johnson and Johnson Surgical Vision, Santa Ana, CA | +2.75 (n) | −0.27 | Bifocal, anterior aspheric and posterior diffractive surface |
| Tecnis ZLB00 | +3.25 (n) | |||
| ATLISA 809M | Carl Zeiss Meditec AG, | +3.75 (n) | −0.18 | Bifocal, aspheric diffractive |
| ATLISATri 839MP | +3.33 (n) | Trifocal, anterior surface with an aspheric diffractive profile | ||
| Tecnis Symfony ZXR00 | Johnson and Johnson Surgical Vision, Santa Ana, CA | ≈+1.75 (i) | −0.27 | Extended depth of focus, wavefront-designed anterior surface, posterior achromatic diffractive surface with echelette design |
| Tecnis ZA9003 | Johnson and Johnson Surgical Vision, Santa Ana, CA | - | −0.27 | Monofocal, anterior aspheric |
Demographic data for each lens type. Results are displayed as mean ± standard deviation (SD) or frequency (gender), with the outcome of the ANOVA or the Kruskal–Wallis tests (p-value). Pupil diameter was measured under photopic conditions. Lens power and pupil diameter correspond to the right eye.
| SVT250 | ZKB00 Bifocal | ZLB00 | ATLISA 809M | ATLISA Tri 839MP | Symfony ZXR00 | ZA9003 |
| |
|---|---|---|---|---|---|---|---|---|
| 19 | 20 | 20 | 18 | 19 | 20 | 36 | ||
| Age (years) | 74.3 ± 7.5 | 68.9 ± 12.9 | 73.3 ± 4.6 | 71.6 ± 7.1 | 68.7 ± 10.3 | 68.2 ± 6.2 | 72.1 ± 5.8 | 0.064 |
| Gender (male/female) | 8/11 | 5/15 | 7/13 | 4/14 | 4/15 | 5/15 | 15/21 | 0.428 |
| IOL power (D) | 21.3 ± 2.4 | 21.6 ± 3.4 | 22.3 ± 1.7 | 22.3 ± 2.4 | 21.9 ± 4.3 | 21.8 ± 5.7 | 21.0 ± 3.6 | 0.832 |
| Pupil diameter (mm) | 3.2 ± 0.6 | 3.4 ± 0.7 | 3.2 ± 0.7 | 3.0 ± 0.6 | 3.3 ± 0.8 | 3.3 ± 0.8 | 3.1 ± 0.7 | 0.768 |
Contrast sensitivity at distance (2.5 m) under photopic (DCSP), mesopic (DCSM) and mesopic with glare (DCSMG), as well as near (33–40 cm) photopic contrast sensitivity (NCSP). Median, maximum and minimum logarithmic values are presented for each lens group and spatial frequency (in cycles per degree, cpd). Also shown are the outcomes of the Kruskal–Wallis test of statistical significance (p-value).
| Spatial | SVT250 | ZKB00 | ZLB00 | ATLISA 809M | ATLISA Tri 839MP | Symfony ZXR00 | ZA9003 |
| |
|---|---|---|---|---|---|---|---|---|---|
| DCSP | 3 cpd | 1.63 | 1.78 | 1.75 | 1.78 | 1.78 | 1.78 | 1.93 | <0.001 |
| 6 cpd | 1.70 | 1.77 | 1.70 | 1.70 | 1.70 | 1.84 | 2.07 | <0.001 | |
| 12 cpd | 1.40 | 1.40 | 1.40 | 1.25 | 1.08 | 1.69 | 1.69 | <0.001 | |
| 18 cpd | 0.81 | 0.96 | 0.81 | 0.81 | 0.64 | 1.10 | 1.25 | <0.001 | |
| DCSM | 3 cpd | 1.49 | 1.71 | 1.63 | 1.63 | 1.63 | 1.63 | 1.78 | 0.001 |
| 6 cpd | 1.70 | 1.84 | 1.70 | 1.84 | 1.70 | 1.84 | 1.99 | <0.001 | |
| 12 cpd | 1.40 | 1.40 | 1.25 | 1.25 | 1.25 | 1.69 | 1.69 | <0.001 | |
| 18 cpd | 0.81 | 0.89 | 0.96 | 0.81 | 0.81 | 1.10 | 1.25 | <0.001 | |
| DCSMG | 3 cpd | 1.56 | 1.63 | 1.63 | 1.63 | 1.49 | 1.78 | 1.78 | <0.001 |
| 6 cpd | 1.70 | 1.70 | 1.84 | 1.70 | 1.70 | 1.99 | 1.99 | <0.001 | |
| 12 cpd | 1.40 | 1.40 | 1.25 | 1.40 | 1.25 | 1.54 | 1.69 | <0.001 | |
| 18 cpd | 0.81 | 0.89 | 0.96 | 0.81 | 0.64 | 1.10 | 1.25 | <0.001 | |
| NCSP | 1.5 cpd | 1.54 | 1.54 | 1.54 | 1.54 | 1.54 | 1.85 | 1.54 | <0.001 |
| 3 cpd | 1.64 | 1.93 | 1.64 | 1.64 | 1.64 | 1.93 | 1.93 | 0.001 | |
| 6 cpd | 1.49 | 1.65 | 1.65 | 1.65 | 1.65 | 1.85 | 1.85 | <0.001 | |
| 12 cpd | 1.18 | 1.51 | 1.18 | 1.51 | 1.51 | 1.51 | 1.74 | <0.001 | |
| 18 cpd | 0.85 | 0.85 | 1.00 | 1.00 | 1.00 | 1.18 | 1.18 | <0.001 |
Figure 1Postoperative binocular corrected distance mean log contrast sensitivity (CS) in photopic, mesopic, mesopic with glare and near photopic conditions.
Figure 2Postoperative binocular corrected photopic distance and near normalized contrast sensitivity (CS) values. The approach reported by Boxer Wachler and Krueger [16] was employed for data normalization.
Quality of vision for each lens type and results of the Kruskal–Wallis test of statistical significance (p-value). All results are percentage of responses.
| SVT250 | ZKB00 Bifocal | ZLB00 | ATLISA 809M | ATLISA Tri 839MP | Symfony ZXR00 | ZA9003 |
| ||
|---|---|---|---|---|---|---|---|---|---|
| Spectacle use at far | Always | 0 | 0 | 0 | 0 | 0 | 5.6 | 11.1 | 0.002 |
| Sometimes | 0 | 0 | 5.0 | 0 | 0 | 5.6 | 13.9 | ||
| Never | 100.0 | 100.0 | 95.0 | 100.0 | 100.0 | 88.9 | 75.0 | ||
| Spectacle use at intermediate | Always | 0 | 0 | 0 | 0 | 0 | 5.6 | 11.1 | 0.033 |
| Sometimes | 10.5 | 5.3 | 10.0 | 0 | 0 | 0 | 13.9 | ||
| Never | 89.5 | 94.7 | 90.0 | 100.0 | 100.0 | 94.4 | 75.0 | ||
| Spectacle use at near | Always | 15.8 | 5.3 | 5.0 | 0 | 0 | 16.7 | 75 | <0.001 |
| Sometimes | 52.6 | 52.6 | 30.0 | 23.5 | 22.2 | 22.2 | 25.0 | ||
| Never | 31.6 | 42.1 | 65.0 | 76.5 | 77.8 | 61.1 | 0 | ||
| Halos occurrence and intensity | None | 84.2 | 42.1 | 50.0 | 35.3 | 50.0 | 38.9 | 94.4 | <0.001 |
| 1 | 5.3 | 26.3 | 15.0 | 11.8 | 5.6 | 16.7 | 5.6 | ||
| 2 | 5.3 | 21.1 | 0 | 17.6 | 27.8 | 44.4 | 0 | ||
| 3 | 5.3 | 10.5 | 35.0 | 35.3 | 16.7 | 0 | 0 | ||
| Glare occurrence and intensity | None | 0 | 0 | 0 | 0 | 5.6 | 0 | 0 | 0.016 |
| 1 | 47.4 | 52.6 | 47.4 | 35.3 | 16.7 | 38.9 | 77.8 | ||
| 2 | 15.8 | 5.3 | 31.6 | 17.6 | 27.8 | 22.2 | 16.7 | ||
| 3 | 21.1 | 21.1 | 5.3 | 29.4 | 11.1 | 5.6 | 0 |