Literature DB >> 28165609

Comparison of visual outcomes after bilateral implantation of extended range of vision and trifocal intraocular lenses.

Ramón Ruiz-Mesa1, Antonio Abengózar-Vela1, Ana Aramburu1, María Ruiz-Santos1.   

Abstract

PURPOSE: To compare visual outcomes after cataract surgery with bilateral implantation of 2 intraocular lenses (IOLs): extended range of vision and trifocal.
METHODS: Each group of this prospective study comprised 40 eyes (20 patients). Phacoemulsification followed by bilateral implantation of a FineVision IOL (group 1) or a Symfony IOL (group 2) was performed. The following outcomes were assessed up to 1 year postoperatively: binocular uncorrected distance visual acuity (UDVA), binocular uncorrected intermediate visual acuity (UIVA) at 60 cm, binocular uncorrected near visual acuity (UNVA) at 40 cm, spherical equivalent (SE) refraction, defocus curves, mesopic and photopic contrast sensitivity, halometry, posterior capsule opacification (PCO), and responses to a patient questionnaire.
RESULTS: The mean binocular values in group 1 and group 2, respectively, were SE -0.15 ± 0.25 D and -0.19 ± 0.18 D; UDVA 0.01 ± 0.03 logMAR and 0.01 ± 0.02 logMAR; UIVA 0.11 ± 0.08 logMAR and 0.09 ± 0.08 logMAR; UNVA 0.06 ± 0.07 logMAR and 0.17 ± 0.06 logMAR. Difference in UNVA between IOLs (p<0.05) was statistically significant. There were no significant differences in contrast sensitivity, halometry, or PCO between groups. Defocus curves were similar between groups from 0 D to -2 D, but showed significant differences from -2.50 D to -4.00 D (p<0.05).
CONCLUSIONS: Both IOLs provided excellent distance and intermediate visual outcomes. The FineVision IOL showed better near visual acuity. Predictability of the refractive results and optical performance were excellent; all patients achieved spectacle independence. The 2 IOLs gave similar and good contrast sensitivity in photopic and mesopic conditions and low perception of halos by patients.

Entities:  

Mesh:

Year:  2017        PMID: 28165609     DOI: 10.5301/ejo.5000935

Source DB:  PubMed          Journal:  Eur J Ophthalmol        ISSN: 1120-6721            Impact factor:   2.597


  25 in total

1.  Quality of vision, patient satisfaction and long-term visual function after bilateral implantation of a low addition multifocal intraocular lens.

Authors:  Emilio Pedrotti; Rodolfo Mastropasqua; Jacopo Bonetto; Christian Demasi; Francesco Aiello; Carlo Nucci; Cesare Mariotti; Giorgio Marchini
Journal:  Int Ophthalmol       Date:  2017-07-17       Impact factor: 2.031

2.  Visual performance of an extended depth of focus intraocular lens for treatment selection.

Authors:  Thomas Kohnen; Myriam Böhm; Eva Hemkeppler; Sabrina Schönbrunn; Nina DeLorenzo; Kerstin Petermann; Michael Herzog
Journal:  Eye (Lond)       Date:  2019-04-26       Impact factor: 3.775

3.  Comparative analysis of visual outcomes, reading skills, contrast sensitivity, and patient satisfaction with two models of trifocal diffractive intraocular lenses and an extended range of vision intraocular lens.

Authors:  Rita Mencucci; Eleonora Favuzza; Orsola Caporossi; Alfonso Savastano; Stanislao Rizzo
Journal:  Graefes Arch Clin Exp Ophthalmol       Date:  2018-07-06       Impact factor: 3.117

4.  Comparison of visual outcomes after two types of mix-and-match implanted trifocal extended-depth-of-focus and trifocal intraocular lenses.

Authors:  Jung Wan Kim; Youngsub Eom; Wonkyung Park; Jong Suk Song; Ji Won Jeong; Seh Kwang Park; Hyo Myung Kim
Journal:  Graefes Arch Clin Exp Ophthalmol       Date:  2022-05-28       Impact factor: 3.535

5.  Trifocal intraocular lenses versus bifocal intraocular lenses after cataract extraction among participants with presbyopia.

Authors:  Diego Zamora-de La Cruz; Karla Zúñiga-Posselt; John Bartlett; Mario Gutierrez; Samuel A Abariga
Journal:  Cochrane Database Syst Rev       Date:  2020-06-18

6.  A clinical assessment of visual performance of combining the TECNIS® Symfony Extended Range of Vision IOL (ZXR00) with the +3.25 D TECNIS Multifocal 1-piece IOL (ZLB00) in subjects undergoing bilateral cataract extraction.

Authors:  Sondra Black
Journal:  Clin Ophthalmol       Date:  2018-10-23

7.  Clinical outcomes with a low add multifocal and an extended depth of focus intraocular lenses both implanted with mini-monovision.

Authors:  Mehmet Orkun Sevik; Semra Akkaya Turhan; Ebru Toker
Journal:  Eye (Lond)       Date:  2021-06-11       Impact factor: 4.456

8.  Rotational stability and visual performance 3 months after bilateral implantation of a new toric extended range of vision intraocular lens.

Authors:  Kjell Gunnar Gundersen
Journal:  Clin Ophthalmol       Date:  2018-07-18

9.  Monocular Clinical Outcomes and Range of Near Vision following Cataract Surgery with Implantation of an Extended Depth of Focus Intraocular Lens.

Authors:  Rahul T Pandit
Journal:  J Ophthalmol       Date:  2018-12-13       Impact factor: 1.909

10.  Visual Performances of a New Extended Depth-of-Focus Intraocular Lens with a Refractive Design: A Prospective Study After Bilateral Implantation.

Authors:  Leopoldo Spadea; Maria Ilaria Giannico; Martina Formisano; Ludovico Alisi
Journal:  Ther Clin Risk Manag       Date:  2021-07-16       Impact factor: 2.423