Evaluation the loosening of abutment screws in fluid contamination: an in vitro study.

Fei Sun1, Wei Cheng1, Bao-Hong Zhao2, Gui-Qiu Song1, Zeng Lin3.   

Abstract

Screw loosening is one of the most common clinical problems of dental implants. Research on the influencing factors of screw loosening is very important to prevent screw loosening. The purpose of this in vitro study was to evaluate the influence of liquid contamination on the screw loosening. According to the contamination condition, forty-five abutment screws were divided into three groups (n = 15): no contamination, artificial saliva contamination, and mouthwash contamination. The preload and friction coefficient of the abutment screws were recorded. Then, the reverse torque values (RTVs) and settlement were measured after 3.0 × 105 and 6.0 × 105 cycles. The surface wear of the screws was analyzed. Finally, the stress distribution of the abutment screws was calculated by finite element analysis (FEA). The results showed that fluid contamination reduced the friction coefficient, increased the preload, decrease the settlement, improved resistance to screw loosening, and reduced wear on the thread surface. Appropriate antimicrobial lubrication may improve the anti-loosening performance of abutment screws and prevent excessive wear on the threaded surface.
© 2022. The Author(s).

Entities:  

Mesh:

Substances:

Year:  2022        PMID: 35750776      PMCID: PMC9232564          DOI: 10.1038/s41598-022-14791-w

Source DB:  PubMed          Journal:  Sci Rep        ISSN: 2045-2322            Impact factor:   4.996


  34 in total

1.  Osseointegrated implants for single tooth replacement: a 1-year report from a multicenter prospective study.

Authors:  T Jemt; W R Laney; D Harris; P J Henry; P H Krogh; G Polizzi; G A Zarb; I Herrmann
Journal:  Int J Oral Maxillofac Implants       Date:  1991       Impact factor: 2.804

2.  Detorque evaluation of dental abutment screws after immersion in a fluoridated artificial saliva solution.

Authors:  Antônio R C Duarte; João P Silva Neto; Júlio C M Souza; Wellington C Bonachela
Journal:  J Prosthodont       Date:  2012-10-25       Impact factor: 2.752

3.  Interaction of chlorhexidine with smooth and rough types of titanium surfaces.

Authors:  Avital Kozlovsky; Zvi Artzi; Ofer Moses; Nurit Kamin-Belsky; Ronit Bar-Ness Greenstein
Journal:  J Periodontol       Date:  2006-07       Impact factor: 6.993

4.  Comparison of screw loosening, rotation, and deflection among three implant designs.

Authors:  D L Dixon; L C Breeding; J P Sadler; M L McKay
Journal:  J Prosthet Dent       Date:  1995-09       Impact factor: 3.426

5.  Effect of preload torque on the ultimate tensile strength of implant prosthetic retaining screws.

Authors:  M J Jaarda; M E Razzoog; D G Gratton
Journal:  Implant Dent       Date:  1994       Impact factor: 2.454

6.  Influence of abutment materials on the implant-abutment joint stability in internal conical connection type implant systems.

Authors:  Jae-Young Jo; Dong-Seok Yang; Jung-Bo Huh; Jae-Chan Heo; Mi-Jung Yun; Chang-Mo Jeong
Journal:  J Adv Prosthodont       Date:  2014-12-17       Impact factor: 1.904

7.  Effect of central screw taper angles on the loosening performance and fatigue characteristics of dental implants.

Authors:  Fei Sun; Li-Tao Lv; Ding-Ding Xiang; De-Chun Ba; Zeng Lin; Gui-Qiu Song
Journal:  J Mech Behav Biomed Mater       Date:  2022-02-24

8.  Preload and torque removal evaluation of three different abutment screws for single standing implant restorations.

Authors:  Rafael Augusto Stüker; Eduardo Rolim Teixeira; João Carlos Pinheiro Beck; Nilza Pereira da Costa
Journal:  J Appl Oral Sci       Date:  2008 Jan-Feb       Impact factor: 2.698

9.  Settling of abutments into implants and changes in removal torque in five different implant-abutment connections. Part 1: Cyclic loading.

Authors:  Ki-Seong Kim; Jung-Suk Han; Young-Jun Lim
Journal:  Int J Oral Maxillofac Implants       Date:  2014 Sep-Oct       Impact factor: 2.804

10.  Comparison of a Novel Ultrasonic Scaler Tip vs. Conventional Design on a Titanium Surface.

Authors:  Bruna Sinjari; Gianmaria D'Addazio; Martina Bozzi; Renato Celletti; Tonino Traini; Luan Mavriqi; Sergio Caputi
Journal:  Materials (Basel)       Date:  2018-11-22       Impact factor: 3.623

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.