Literature DB >> 7473281

Comparison of screw loosening, rotation, and deflection among three implant designs.

D L Dixon1, L C Breeding, J P Sadler, M L McKay.   

Abstract

A common problem associated with single tooth implant restorations is abutment screw loosening. Manufacturers of implants have attempted to overcome this problem by incorporating antirotational design characteristics into their systems. Micromovement and torque levels required to loosen abutment screws for straight and angled antirotational screw-retained abutment/implant combinations from three different manufacturers were examined in this in vitro investigation. A custom-built machine was used and each sample was subjected to compressive horizontal reciprocal movements over a 25-degree incline for a simulated 1-month period. Data were generated that showed movements of the crown/abutment complex during force application. The amount of torque necessary to loosen the abutment screws before and after testing was also recorded and compared for each system. The results indicated no significant differences (p < 0.05) among all the straight and angled abutments for the variables studied.

Mesh:

Substances:

Year:  1995        PMID: 7473281     DOI: 10.1016/s0022-3913(05)80134-9

Source DB:  PubMed          Journal:  J Prosthet Dent        ISSN: 0022-3913            Impact factor:   3.426


  14 in total

Review 1.  Management of abutment screw loosening: review of literature and report of a case.

Authors:  Vinod Krishnan; C Tony Thomas; Ipe Sabu
Journal:  J Indian Prosthodont Soc       Date:  2013-10-25

2.  Evaluation the loosening of abutment screws in fluid contamination: an in vitro study.

Authors:  Fei Sun; Wei Cheng; Bao-Hong Zhao; Gui-Qiu Song; Zeng Lin
Journal:  Sci Rep       Date:  2022-06-24       Impact factor: 4.996

3.  Loosening torque of Universal Abutment screws after cyclic loading: influence of tightening technique and screw coating.

Authors:  Atais Bacchi; Alexandre Regalin; Claudia Lopes Brilhante Bhering; Rodrigo Alessandretti; Aloisio Oro Spazzin
Journal:  J Adv Prosthodont       Date:  2015-10-28       Impact factor: 1.904

4.  Influence of the implant-abutment connection design and diameter on the screw joint stability.

Authors:  Hyon-Mo Shin; Jung-Bo Huh; Mi-Jeong Yun; Young-Chan Jeon; Brian Myung Chang; Chang-Mo Jeong
Journal:  J Adv Prosthodont       Date:  2014-04-22       Impact factor: 1.904

5.  Leakage evaluation of original and compatible implant-abutment connections: In vitro study using Rhodamine B.

Authors:  Antoine Berberi; George Tehini; Khaldoun Rifai; Farah Bou Nasser Eddine; Bassam Badran; Haidar Akl
Journal:  J Dent Biomech       Date:  2014-08-11

6.  Effect of cyclic load on vertical misfit of prefabricated and cast implant single abutment.

Authors:  Rudys Rodolfo de Jesus Tavarez; Wellington Cardoso Bonachela; Anuar Antônio Xible
Journal:  J Appl Oral Sci       Date:  2011 Jan-Feb       Impact factor: 2.698

7.  Influence of the connection design and titanium grades of the implant complex on resistance under static loading.

Authors:  Su-Jung Park; Suk-Won Lee; Richard Leesungbok; Su-Jin Ahn
Journal:  J Adv Prosthodont       Date:  2016-10-21       Impact factor: 1.904

8.  Evaluation of stability of interface between CCM (Co-Cr-Mo) UCLA abutment and external hex implant.

Authors:  Ki-Joon Yoon; Young-Bum Park; Hyunmin Choi; Youngsung Cho; Jae-Hoon Lee; Keun-Woo Lee
Journal:  J Adv Prosthodont       Date:  2016-12-15       Impact factor: 1.904

Review 9.  Preload loss of abutment screws after dynamic fatigue in single implant-supported restorations. A systematic review.

Authors:  Beatriz Pardal-Peláez; Javier Montero
Journal:  J Clin Exp Dent       Date:  2017-11-01

10.  In vitro evaluation of leakage at implant-abutment connection of three implant systems having the same prosthetic interface using rhodamine B.

Authors:  Antoine Berberi; Georges Tehini; Khaldoun Rifai; Farah Bou Nasser Eddine; Nabil El Zein; Bassam Badran; Haidar Akl
Journal:  Int J Dent       Date:  2014-05-11
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.