Literature DB >> 25551010

Influence of abutment materials on the implant-abutment joint stability in internal conical connection type implant systems.

Jae-Young Jo1, Dong-Seok Yang1, Jung-Bo Huh1, Jae-Chan Heo2, Mi-Jung Yun1, Chang-Mo Jeong1.   

Abstract

PURPOSE: This study evaluated the influence of abutment materials on the stability of the implant-abutment joint in internal conical connection type implant systems.
MATERIALS AND METHODS: Internal conical connection type implants, cement-retained abutments, and tungsten carbide-coated abutment screws were used. The abutments were fabricated with commercially pure grade 3 titanium (group T3), commercially pure grade 4 titanium (group T4), or Ti-6Al-4V (group TA) (n=5, each). In order to assess the amount of settlement after abutment fixation, a 30-Ncm tightening torque was applied, then the change in length before and after tightening the abutment screw was measured, and the preload exerted was recorded. The compressive bending strength was measured under the ISO14801 conditions. In order to determine whether there were significant changes in settlement, preload, and compressive bending strength before and after abutment fixation depending on abutment materials, one-way ANOVA and Tukey's HSD post-hoc test was performed.
RESULTS: Group TA exhibited the smallest mean change in the combined length of the implant and abutment before and after fixation, and no difference was observed between groups T3 and T4 (P>.05). Group TA exhibited the highest preload and compressive bending strength values, followed by T4, then T3 (P<.001).
CONCLUSION: The abutment material can influence the stability of the interface in internal conical connection type implant systems. The strength of the abutment material was inversely correlated with settlement, and positively correlated with compressive bending strength. Preload was inversely proportional to the frictional coefficient of the abutment material.

Entities:  

Keywords:  Abutment material; Compressive bending strength; Implant; Interface stability; Preload

Year:  2014        PMID: 25551010      PMCID: PMC4279048          DOI: 10.4047/jap.2014.6.6.491

Source DB:  PubMed          Journal:  J Adv Prosthodont        ISSN: 2005-7806            Impact factor:   1.904


  36 in total

1.  Implant abutment screw rotations and preloads for four different screw materials and surfaces.

Authors:  W C Martin; R D Woody; B H Miller; A W Miller
Journal:  J Prosthet Dent       Date:  2001-07       Impact factor: 3.426

Review 2.  Implant screw mechanics and the settling effect: overview.

Authors:  Sheldon Winkler; Karla Ring; Jamie D Ring; Kenneth G Boberick
Journal:  J Oral Implantol       Date:  2003       Impact factor: 1.779

3.  Single implant-supported molar and premolar crowns: a ten-year retrospective clinical report.

Authors:  Robert L Simon
Journal:  J Prosthet Dent       Date:  2003-12       Impact factor: 3.426

4.  The longitudinal clinical effectiveness of osseointegrated dental implants: the Toronto study. Part III: Problems and complications encountered.

Authors:  G A Zarb; A Schmitt
Journal:  J Prosthet Dent       Date:  1990-08       Impact factor: 3.426

5.  Effects of abutment screw coating on implant preload.

Authors:  Jae-Kyoung Park; Jin-Uk Choi; Young-Chan Jeon; Kyung-Soo Choi; Chang-Mo Jeong
Journal:  J Prosthodont       Date:  2010-04-23       Impact factor: 2.752

6.  Influence of abutment material on the gingival color of implant-supported all-ceramic restorations: a prospective multicenter study.

Authors:  Eriberto Bressan; Gianluca Paniz; Diego Lops; Boris Corazza; Eugenio Romeo; Gianantonio Favero
Journal:  Clin Oral Implants Res       Date:  2010-11-11       Impact factor: 5.977

7.  Influence of implant/abutment joint designs on abutment screw loosening in a dental implant system.

Authors:  Tsuyoshi Kitagawa; Yasuhiro Tanimoto; Misako Odaki; Kimiya Nemoto; Masahiro Aida
Journal:  J Biomed Mater Res B Appl Biomater       Date:  2005-11       Impact factor: 3.368

Review 8.  Abutment screw loosening in single-implant restorations: a systematic review.

Authors:  Anna Theoharidou; Haralampos P Petridis; Konstantinos Tzannas; Pavlos Garefis
Journal:  Int J Oral Maxillofac Implants       Date:  2008 Jul-Aug       Impact factor: 2.804

9.  Carbon film coating of abutment surfaces: effect on the abutment screw removal torque.

Authors:  Pedro Henrique Corazza; Alecsandro de Moura Silva; José Renato Cavalcanti Queiroz; Susana María Salazar Marocho; Marco Antonia Bottino; Marcos Massi; Rodrigo Othávio de Assunção e Souza
Journal:  Implant Dent       Date:  2014-08       Impact factor: 2.454

10.  A 15-year study of osseointegrated implants in the treatment of the edentulous jaw.

Authors:  R Adell; U Lekholm; B Rockler; P I Brånemark
Journal:  Int J Oral Surg       Date:  1981-12
View more
  6 in total

1.  Evaluation the loosening of abutment screws in fluid contamination: an in vitro study.

Authors:  Fei Sun; Wei Cheng; Bao-Hong Zhao; Gui-Qiu Song; Zeng Lin
Journal:  Sci Rep       Date:  2022-06-24       Impact factor: 4.996

Review 2.  Systematic analysis of factors that cause loss of preload in dental implants.

Authors:  S Nithyapriya; A S Ramesh; A Kirubakaran; Jeevitha Mani; J Raghunathan
Journal:  J Indian Prosthodont Soc       Date:  2018 Jul-Sep

Review 3.  Sandblasted and Acid Etched Titanium Dental Implant Surfaces Systematic Review and Confocal Microscopy Evaluation.

Authors:  Gabriele Cervino; Luca Fiorillo; Gaetano Iannello; Dario Santonocito; Giacomo Risitano; Marco Cicciù
Journal:  Materials (Basel)       Date:  2019-05-30       Impact factor: 3.623

4.  Comparison of CAD/CAM abutment and prefabricated abutment in Morse taper internal type implant after cyclic loading: Axial displacement, removal torque, and tensile removal force.

Authors:  Yuseung Yi; Seong-Joo Heo; Jai-Young Koak; Seong-Kyun Kim
Journal:  J Adv Prosthodont       Date:  2019-12-18       Impact factor: 1.904

5.  Influence of Implant Connection, Abutment Design and Screw Insertion Torque on Implant-Abutment Misfit.

Authors:  Jorge Vélez; Jesús Peláez; Carlos López-Suárez; Rubén Agustín-Panadero; Celia Tobar; María J Suárez
Journal:  J Clin Med       Date:  2020-07-24       Impact factor: 4.241

6.  Microleakage assessment of CAD-CAM Cobalt-Chrome and Zirconia abutments on a conical connection dental implant: A comparative in vitro study.

Authors:  Pedro Molinero-Mourelle; Andrea Roccuzzo; Burak Yilmaz; Walter Yu Hang Lam; Edmond H N Pow; Jaime Del Río Highsmith; Miguel Gómez-Polo
Journal:  Clin Oral Implants Res       Date:  2022-07-21       Impact factor: 5.021

  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.