| Literature DB >> 35612645 |
Felix Schmeiser1, Uwe Baumert2, Bogna Stawarczyk3.
Abstract
OBJECTIVES: To investigate the two-body wear of occlusal splint materials fabricated from subtractive computer-aided manufacturing (CAM) compared to three-dimensional printing (3DP).Entities:
Keywords: 3D printing; Abrasion losses; Computer-aided manufacturing; Mastication simulation; Occlusal splint materials; Two-body wear
Mesh:
Substances:
Year: 2022 PMID: 35612645 PMCID: PMC9474371 DOI: 10.1007/s00784-022-04543-5
Source DB: PubMed Journal: Clin Oral Investig ISSN: 1432-6981 Impact factor: 3.606
Fig. 1Study design
Compositions of the base materials used for the CAM blanks and the photopolymer resin for 3DP based on information provided by the manufacturers (m, mass percent; n.g., not given)
| Material | Brand | Component | Composition | |
|---|---|---|---|---|
| CAM-TD | Thermeo | Blank | Methacrylate polymer | < 100 |
| Dibenzoyl peroxide | < 1 | |||
| Liquid | 1,2-Cyclohexane dicarboxylic acid diisononyl ester | < 20 | ||
| Tetrahydrofurfuryl methacrylate | < 40 | |||
| 2-Ethoxyethyl methacrylate | < 50 | |||
| CAM-CL | Astron CLEARsplint | Blank | Methacrylate polymer | 75–100 |
| Dibenzoyl peroxide | 0.1–3 | |||
| Liquid | 2-Ethoxyethyl methacrylate | 75–100 | ||
| 3DP-GI | GR-22 Flex | Resin | Oligomers, methacrylic resins, multifunctional | < 75 |
| Methacrylic resins, monofunctional | > 25 | |||
| Photoinitiators (various) | < 2 (in total) | |||
| Pigments/stabilizers | n.g | |||
| 3DP-KY | KeySplint Soft | Resin | Methacrylate monomer 1 | ≤ 50 |
| Methacrylate monomer 2 | < 3 | |||
| Methacrylate monomer 3 | ≤ 25 | |||
| Photoinitiator 1 | < 3 |
Fig. 2Preparation, development and positioning of the crown-shaped substrate
Relative frequencies (%) with 95% CI of failure types after mastication simulation
| Material | Brand (statistics) | Failure types after mastication simulation | ||
|---|---|---|---|---|
| CAM-TD | Thermeo | |||
| 6 (50) | 5 (42) | 0 (0) | ||
| 95% CI | (14; 73) | (14; 73) | (0; 27) | |
| CAM-CL | Astron CLEARsplint | |||
| 11 (92) | 1 (8) | 0 (0) | ||
| 95% CI | (60; 100) | (0; 39) | (0; 27) | |
| CAM | Total | |||
| 17 (71) | 6 (25) | 0 (0) | ||
| 3DP-GI | GR-22-flex | |||
| 4 (33) | (0) | 8 (67) | ||
| 95% CI | (9; 66) | (0; 27) | (33; 91) | |
| 3DP-KY | KeySplint Soft | |||
| 5 (42) | (0) | 7 (58) | ||
| 95% CI | (14; 73) | (0; 27) | (26; 85) | |
| 3DP | Total | |||
| 9 (38) | 0 (0) | 15 (63) | ||
Descriptive statistics of two-body wear results with mean ± standard deviation (SD) and 95% confidence intervals (CI)
| Thermeo | 6 | − 0.82 ± 0.41 | (− 0.54; − 1.09) | − 3.51 ± 1.87 | (− 2.31; − 4.70) |
| Astron CLEARsplint | 11 | − 0.56 ± 0.25 | (− 0.42; − 0.76) | − 2.58 ± 1.34 | (− 1.71; − 3.43) |
| GR-22 flex | 4 | − 0.45 ± 0.18 | (− 0.14; − 0.75) | − 1.76 ± 1.39 | (− 0.45; − 3.98) |
| KeySplint Soft | 5 | − 0.51 ± 0.09 | (− 0.38; − 0.62) | − 1.62 ± 0.67 | (− 0.77; − 2.45) |
Fig. 3Correlation curve between vertical and volumetric losses (r = 0.887, p < 0.001)
Fig. 4Microscopic images especially of damage patterns from the abrasion surfaces with Keyence VHX 6000
Fig. 5Illustration of the printing direction of the substrates and the respective force direction in the mastication simulator