Literature DB >> 28089336

A comparative study of additive and subtractive manufacturing for dental restorations.

Eun-Jeong Bae1, Il-Do Jeong2, Woong-Chul Kim3, Ji-Hwan Kim4.   

Abstract

STATEMENT OF PROBLEM: Digital systems have recently found widespread application in the fabrication of dental restorations. For the clinical assessment of dental restorations fabricated digitally, it is necessary to evaluate their accuracy. However, studies of the accuracy of inlay restorations fabricated with additive manufacturing are lacking.
PURPOSE: The purpose of this in vitro study was to evaluate and compare the accuracy of inlay restorations fabricated by using recently introduced additive manufacturing with the accuracy of subtractive methods.
MATERIAL AND METHODS: The inlay (distal occlusal cavity) shape was fabricated using 3-dimensional image (reference data) software. Specimens were fabricated using 4 different methods (each n=10, total N=40), including 2 additive manufacturing methods, stereolithography apparatus and selective laser sintering; and 2 subtractive methods, wax and zirconia milling. Fabricated specimens were scanned using a dental scanner and then compared by overlapping reference data. The results were statistically analyzed using a 1-way analysis of variance (α=.05). Additionally, the surface morphology of 1 randomly (the first of each specimen) selected specimen from each group was evaluated using a digital microscope.
RESULTS: The results of the overlap analysis of the dental restorations indicated that the root mean square (RMS) deviation observed in the restorations fabricated using the additive manufacturing methods were significantly different from those fabricated using the subtractive methods (P<.05). However, no significant differences were found between restorations fabricated using stereolithography apparatus and selective laser sintering, the additive manufacturing methods (P=.466). Similarly, no significant differences were found between wax and zirconia, the subtractive methods (P=.986). The observed RMS values were 106 μm for stereolithography apparatus, 113 μm for selective laser sintering, 116 μm for wax, and 119 μm for zirconia. Microscopic evaluation of the surface revealed a fine linear gap between the layers of restorations fabricated using stereolithography apparatus and a grooved hole with inconsistent weak scratches when fabricated using selective laser sintering. In the wax and zirconia restorations, possible traces of milling bur passes were observed.
CONCLUSIONS: The results indicate that the accuracy of dental restorations fabricated using the additive manufacturing methods is higher than that of subtractive methods. Therefore, additive manufacturing methods are a viable alternative to subtractive methods.
Copyright © 2016 Editorial Council for the Journal of Prosthetic Dentistry. Published by Elsevier Inc. All rights reserved.

Entities:  

Mesh:

Year:  2017        PMID: 28089336     DOI: 10.1016/j.prosdent.2016.11.004

Source DB:  PubMed          Journal:  J Prosthet Dent        ISSN: 0022-3913            Impact factor:   3.426


  13 in total

1.  Influence of cleaning methods after 3D printing on two-body wear and fracture load of resin-based temporary crown and bridge material.

Authors:  Johannes Mayer; Bogna Stawarczyk; Konstantin Vogt; Reinhard Hickel; Daniel Edelhoff; Marcel Reymus
Journal:  Clin Oral Investig       Date:  2021-04-03       Impact factor: 3.573

Review 2.  Current status and applications of additive manufacturing in dentistry: A literature-based review.

Authors:  Mohd Javaid; Abid Haleem
Journal:  J Oral Biol Craniofac Res       Date:  2019-04-16

3.  Foot Orthosis and Sensorized House Slipper by 3D Printing.

Authors:  Lorenzo Brognara; Massimiliano Fantini; Kavin Morellato; Gabriela Graziani; Nicola Baldini; Omar Cauli
Journal:  Materials (Basel)       Date:  2022-06-08       Impact factor: 3.748

Review 4.  3D printing restorative materials using a stereolithographic technique: a systematic review.

Authors:  Alvaro Della Bona; Viviane Cantelli; Vitor T Britto; Kaue F Collares; Jeffrey W Stansbury
Journal:  Dent Mater       Date:  2021-01-19       Impact factor: 5.304

5.  Shear bond strength of provisional repair materials bonded to 3D printed resin.

Authors:  Rami Albahri; Hyung-In Yoon; Jason D Lee; Sena Yoon; Sang J Lee
Journal:  J Dent Sci       Date:  2020-05-30       Impact factor: 2.080

6.  Evaluating the accuracy of three intraoral scanners using models containing different numbers of crown-prepared abutments.

Authors:  Ting Zhang; Ting Wei; Yawen Zhao; Mengyang Jiang; Xiaojie Yin; Huiqiang Sun
Journal:  J Dent Sci       Date:  2021-06-01       Impact factor: 2.080

7.  Fit Accuracy of Removable Partial Denture Frameworks Fabricated with CAD/CAM, Rapid Prototyping, and Conventional Techniques: A Systematic Review.

Authors:  Naseer Ahmed; Maria Shakoor Abbasi; Sara Haider; Nimra Ahmed; Syed Rashid Habib; Sara Altamash; Muhammad Sohail Zafar; Mohammad Khursheed Alam
Journal:  Biomed Res Int       Date:  2021-09-06       Impact factor: 3.411

8.  A study on the machining accuracy of dental digital method focusing on dental inlay.

Authors:  Eun-Jeong Bae; Il-Do Jeong; Woong-Chul Kim; Ji-Hwan Kim
Journal:  J Adv Prosthodont       Date:  2018-08-17       Impact factor: 1.904

9.  Digitally Fabricated Dentures for Full Mouth Rehabilitation with Zirconia, Polyetheretherketone and Selective Laser Melted Ti-6Al-4V Material.

Authors:  Wei-Ting Lee; Yung-Chung Chen
Journal:  Int J Environ Res Public Health       Date:  2022-03-04       Impact factor: 3.390

10.  Marginal and internal fit of crowns based on additive or subtractive manufacturing.

Authors:  Yasser Haddadi; Bahram Ranjkesh; Flemming Isidor; Golnosh Bahrami
Journal:  Biomater Investig Dent       Date:  2021-06-26
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.