Literature DB >> 31612354

Surface roughness and wear behavior of occlusal splint materials made of contemporary and high-performance polymers.

Merve Benli1, Beril Eker Gümüş2, Yusuf Kahraman2, Bilge Gökçen-Rohlig1, Gülümser Evlioğlu1, Olivier Huck3,4,5, Mutlu Özcan6.   

Abstract

With the development of a digital technology of computer-assisted manufacturing (CAD/CAM) and new age materials, the use of new types of occlusal splint is to consider. The aim of the present study was to evaluate the surface roughness (Ra) and wear behavior of different CAD/CAM materials against enamel antagonist through a simulated chewing test. A total of 75 specimens made from ethylene vinyl acetate (EVA), polymethyl methacrylate (PMMA), polycarbonate (PC), polyetheretherketone (PEEK), and polyethyleneterephthalate (PETG) as a control were polished to evaluate the Ra before loading by optical profilometry and further analyzed by scanning electron microscopy (SEM). Specimens of each group were subjected to thermomechanical fatigue loading in a chewing simulator (60000 cycles at 49 N with 5-55 °C thermocycling). The wear volume loss and change in Ra of each specimen after the simulated chewing were analyzed. One-way ANOVA, paired samples t test, and Pearson correlation analysis were performed for statistical analyzes. The result showed that the volume loss and Ra varied among the materials tested. EVA exhibited the greatest amount of Ra and volume loss (p < 0.001), while PEEK had the lowest values for both (p < 0.001). In terms of volume loss, there was no significant difference between PC and PMMA (p > 0.05). SEM investigations revealed different wear behaviors, especially in EVA. As PEEK showed significantly more favorable results, PEEK splints should be considered as a new therapeutic option for occlusal splint.

Entities:  

Keywords:  EVA; Occlusal splint; PEEK; Surface roughness; Wear

Mesh:

Substances:

Year:  2019        PMID: 31612354     DOI: 10.1007/s10266-019-00463-1

Source DB:  PubMed          Journal:  Odontology        ISSN: 1618-1247            Impact factor:   2.634


  44 in total

1.  Quantitative study of bite force during sleep associated bruxism.

Authors:  K Nishigawa; E Bando; M Nakano
Journal:  J Oral Rehabil       Date:  2001-05       Impact factor: 3.837

2.  Property maps for abrasion resistance of materials.

Authors:  F W Zok; A Miserez
Journal:  Acta Mater       Date:  2007-10       Impact factor: 8.203

3.  Digital Michigan splint - from intraoral scanning to plasterless manufacturing.

Authors:  Philipp Dedem; Jens C Türp
Journal:  Int J Comput Dent       Date:  2016       Impact factor: 1.883

4.  Parallel Randomized Controlled Clinical Trial in Patients with Temporomandibular Disorders Treated with a CAD/CAM Versus a Conventional Stabilization Splint.

Authors:  Jean Marc Pho Duc; Sandra Vargas Hüning; Márcio Lima Grossi
Journal:  Int J Prosthodont       Date:  2016 Jul-Aug       Impact factor: 1.681

5.  CAD/CAM splints for the functional and esthetic evaluation of newly defined occlusal dimensions.

Authors:  Daniel Edelhoff; Josef Schweiger; Otto Prandtner; Johannes Trimpl; Michael Stimmelmayr; Jan-Frederik Güth
Journal:  Quintessence Int       Date:  2017       Impact factor: 1.677

6.  An in vitro study into the effect of a limited range of denture cleaners on surface roughness and removal of Candida albicans from conventional heat-cured acrylic resin denture base material.

Authors:  Z Harrison; A Johnson; C W I Douglas
Journal:  J Oral Rehabil       Date:  2004-05       Impact factor: 3.837

7.  Antagonist wear of three CAD/CAM anatomic contour zirconia ceramics.

Authors:  Ji-Hee Park; Sangwon Park; Kwangmin Lee; Kwi-Dug Yun; Hyun-Pil Lim
Journal:  J Prosthet Dent       Date:  2013-11-05       Impact factor: 3.426

8.  Tensile properties of mineralized and demineralized human and bovine dentin.

Authors:  H Sano; B Ciucchi; W G Matthews; D H Pashley
Journal:  J Dent Res       Date:  1994-06       Impact factor: 6.116

9.  Two-body wear rate of PEEK, CAD/CAM resin composite and PMMA: Effect of specimen geometries, antagonist materials and test set-up configuration.

Authors:  Timea Wimmer; Anne Mildred Sophie Huffmann; Marlis Eichberger; Patrick R Schmidlin; Bogna Stawarczyk
Journal:  Dent Mater       Date:  2016-03-28       Impact factor: 5.304

10.  Patient responses to vacuum formed splints compared to heat cured acrylic splints: pilot study.

Authors:  Aysen Nekora; Gulümser Evlioglu; Arzu Ceyhan; Haluk Keskin; Halim Issever
Journal:  J Maxillofac Oral Surg       Date:  2009-06-10
View more
  5 in total

1.  Microbial Adhesion to Dental Polymers for Conventional, Computer-Aided Subtractive and Additive Manufacturing: A Comparative In Vitro Study.

Authors:  Sergey Arutyunov; Levon Kirakosyan; Lubov Dubova; Yaser Kharakh; Nikolay Malginov; Gadzhi Akhmedov; Viktor Tsarev
Journal:  J Funct Biomater       Date:  2022-04-11

2.  Investigation on the Potential Use of Polypropylene Mesh for the Reinforcement of Heat-Polymerized PMMA Denture Base Resin.

Authors:  Kaan Yerliyurt; Sinan Eğri
Journal:  Polymers (Basel)       Date:  2022-08-12       Impact factor: 4.967

3.  Two-body wear of occlusal splint materials from subtractive computer-aided manufacturing and three-dimensional printing.

Authors:  Felix Schmeiser; Uwe Baumert; Bogna Stawarczyk
Journal:  Clin Oral Investig       Date:  2022-05-25       Impact factor: 3.606

Review 4.  The use of PEEK in digital prosthodontics: A narrative review.

Authors:  Ioannis Papathanasiou; Phophi Kamposiora; George Papavasiliou; Marco Ferrari
Journal:  BMC Oral Health       Date:  2020-08-02       Impact factor: 2.757

5.  The Effect of Salinized Nano ZrO2 Particles on the Microstructure, Hardness, and Wear Behavior of Acrylic Denture Tooth Nanocomposite.

Authors:  Kawkb M El-Tamimi; Dalia A Bayoumi; Mohamed M Z Ahmed; Ibrahim Albaijan; Mohammed E El-Sayed
Journal:  Polymers (Basel)       Date:  2022-01-12       Impact factor: 4.329

  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.