Two-body wear rate of PEEK, CAD/CAM resin composite and PMMA: Effect of specimen geometries, antagonist materials and test set-up configuration.

Timea Wimmer1, Anne Mildred Sophie Huffmann1, Marlis Eichberger1, Patrick R Schmidlin2, Bogna Stawarczyk3.   

Abstract

OBJECTIVE: To test and compare the two-body wear rate of three CAD/CAM polymer materials and the influence of specimen geometry, antagonist material and test set-up configuration.
METHODS: Three CAD/CAM polymeric materials were assessed: a thermoplastic polyetheretherketone (PEEK), an experimental nanohybrid composite (COMP) and a PMMA-based material (PMMA). Crown-shaped and flat specimens were prepared from each material. The specimens underwent thermo-mechanical loading (50N, 5/55°C; 600,000 chewing cycles) opposed to human enamel and stainless steel antagonists. Half of the specimens of each group were loaded with a sliding movement of 0.7mm, the remaining half without. Thereby, 24 different test set-ups were investigated (n=12). Wear of the materials and antagonists was evaluated with a match-3D procedure. The topography of all surfaces was examined with scanning electron microscopy (SEM). Data were statistically evaluated with four-/one-way ANOVA followed by Scheffé post hoc test and unpaired t-test (p<0.05).
RESULTS: All PEEK specimens showed significantly less material loss than COMP and PMMA specimens when loaded laterally. Within the axial loaded groups this was only true for the flat specimens tested with enamel antagonists. Crown specimens of these groups exhibited lower loss values than flat ones. Lateral force application led mostly to significantly higher material loss than the axial load application. On the antagonist side, no impact of CAD/CAM polymer material, antagonist material, force application and specimen geometry was found. SIGNIFICANCE: Wear of PEEK was lower than that of the resin-based materials when lateral forces were applied, but showed comparable antagonist wear rates at the same time.
Copyright © 2016 Academy of Dental Materials. Published by Elsevier Ltd. All rights reserved.

Entities:  

Keywords:  CAD/CAM; Composite; Crown; Enamel; Flat specimens; PEEK; Two-body wear

Mesh:

Substances:

Year:  2016        PMID: 27033460     DOI: 10.1016/j.dental.2016.03.005

Source DB:  PubMed          Journal:  Dent Mater        ISSN: 0109-5641            Impact factor:   5.304


  14 in total

1.  Surface roughness and wear behavior of occlusal splint materials made of contemporary and high-performance polymers.

Authors:  Merve Benli; Beril Eker Gümüş; Yusuf Kahraman; Bilge Gökçen-Rohlig; Gülümser Evlioğlu; Olivier Huck; Mutlu Özcan
Journal:  Odontology       Date:  2019-10-14       Impact factor: 2.634

2.  From Guided Surgery to Final Prosthesis with a Fully Digital Procedure: A Prospective Clinical Study on 15 Partially Edentulous Patients.

Authors:  Giorgio Andrea Dolcini; Marco Colombo; Carlo Mangano
Journal:  Int J Dent       Date:  2016-07-14

3.  In Vitro Investigation of Wear of CAD/CAM Polymeric Materials Against Primary Teeth.

Authors:  Jae-Won Choi; Eun-Ju Song; Jong-Hyun Shin; Tae-Sung Jeong; Jung-Bo Huh
Journal:  Materials (Basel)       Date:  2017-12-09       Impact factor: 3.623

4.  Comparison of access-hole filling materials for screw retained implant prostheses: 12-month in vivo study.

Authors:  Rémy Tanimura; Shiro Suzuki
Journal:  Int J Implant Dent       Date:  2017-05-05

5.  Suitability of Secondary PEEK Telescopic Crowns on Zirconia Primary Crowns: The Influence of Fabrication Method and Taper.

Authors:  Susanne Merk; Christina Wagner; Veronika Stock; Marlis Eichberger; Patrick R Schmidlin; Malgorzata Roos; Bogna Stawarczyk
Journal:  Materials (Basel)       Date:  2016-11-08       Impact factor: 3.623

6.  Bonding to Different PEEK Compositions: The Impact of Dental Light Curing Units.

Authors:  Nina Lümkemann; Marlis Eichberger; Bogna Stawarczyk
Journal:  Materials (Basel)       Date:  2017-01-14       Impact factor: 3.623

7.  Does Printing Orientation Matter? In-Vitro Fracture Strength of Temporary Fixed Dental Prostheses after a 1-Year Simulation in the Artificial Mouth.

Authors:  Julian Nold; Christian Wesemann; Laura Rieg; Lara Binder; Siegbert Witkowski; Benedikt Christopher Spies; Ralf Joachim Kohal
Journal:  Materials (Basel)       Date:  2021-01-07       Impact factor: 3.623

8.  Retention force of polyetheretherketone and cobalt-chrome-molybdenum removable dental prosthesis clasps after artificial aging.

Authors:  Felicitas Mayinger; Danka Micovic; Andreas Schleich; Malgorzata Roos; Marlis Eichberger; Bogna Stawarczyk
Journal:  Clin Oral Investig       Date:  2020-10-16       Impact factor: 3.573

Review 9.  The use of PEEK in digital prosthodontics: A narrative review.

Authors:  Ioannis Papathanasiou; Phophi Kamposiora; George Papavasiliou; Marco Ferrari
Journal:  BMC Oral Health       Date:  2020-08-02       Impact factor: 2.757

10.  The color stability and wear resistance of provisional implant restorations: A prospective clinical study.

Authors:  Vasilios Alevizakos; Gergo Mitov; Franziska Teichert; Constantin von See
Journal:  Clin Exp Dent Res       Date:  2020-07-31
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.