Literature DB >> 29663496

Comparison of wear between occlusal splint materials and resin composite materials.

M Reyes-Sevilla1, R H Kuijs1,2, A Werner2, C J Kleverlaan2, F Lobbezoo1.   

Abstract

Tooth wear in bruxing patients often results in a need for treatment with composite restorations. In some cases, bruxing patients receive an occlusal splint as a protective means as well. However, the wear between these opposing materials has not been investigated yet. The aim of this in vitro study was to assess the wear of different splint materials against resin composite materials. A two-body wear test was conducted using the ACTA wear machine. The materials selected for this study were three composites used for direct restorations (Filtek Z250, CLEARFIL AP-X, and Filtek Supreme XT) and four occlusal splints materials, viz. a polyamide resin (ThermoSens) an conventional (hand-processed), milled and printed polymethylmethacrylate (PMMA). As antagonistic materials, stainless steel, Filtek Supreme XT and CLEARFIL AP-X were used. The wear rate of the seven materials was determined after 200 000 cycles, using a profilometry. The rates were analysed using two-way ANOVA and post hoc Tukey's tests. The wear rates were significantly higher for the conventional and milled PMMA materials than for all other materials (P < .001). The wear rates of printed PMMA and the polyamide resin were comparable to composite wear rates. The antagonist materials have minor or no influence on the amount of wear of the various splint materials (P < .001). In conclusion, different splint materials yielded different wear rates for all antagonist materials tested. Keeping in mind that this study is an experimental in vitro study, this finding enables practitioners to choose the splint material necessary according to their patients' needs.
© 2018 John Wiley & Sons Ltd.

Entities:  

Keywords:  PMMA; attrition; bruxism; splint; tooth wear

Mesh:

Substances:

Year:  2018        PMID: 29663496     DOI: 10.1111/joor.12636

Source DB:  PubMed          Journal:  J Oral Rehabil        ISSN: 0305-182X            Impact factor:   3.837


  5 in total

1.  Surface roughness and wear behavior of occlusal splint materials made of contemporary and high-performance polymers.

Authors:  Merve Benli; Beril Eker Gümüş; Yusuf Kahraman; Bilge Gökçen-Rohlig; Gülümser Evlioğlu; Olivier Huck; Mutlu Özcan
Journal:  Odontology       Date:  2019-10-14       Impact factor: 2.634

2.  Influence of Occlusal Splint on Mandibular Movements in Patients with Bruxism: a Comparative Pilot Study.

Authors:  Josip Škaričić; Samir Čimić; Sonja Kraljević-Šimunković; Marko Vuletić; Nikša Dulčić
Journal:  Acta Stomatol Croat       Date:  2020-09

3.  Two-body wear of occlusal splint materials against different antagonists.

Authors:  Kubra Yildiz Domanic; Yilmaz Umut Aslan; Yasemin Ozkan
Journal:  BMC Oral Health       Date:  2020-06-22       Impact factor: 2.757

4.  Two-body wear of occlusal splint materials from subtractive computer-aided manufacturing and three-dimensional printing.

Authors:  Felix Schmeiser; Uwe Baumert; Bogna Stawarczyk
Journal:  Clin Oral Investig       Date:  2022-05-25       Impact factor: 3.606

5.  Effects of occlusal splint therapy on opposing tooth tissues, filling materials and restorations.

Authors:  Magdalena A Osiewicz; Arie Werner; Franciscus J M Roeters; Cornelis J Kleverlaan
Journal:  J Oral Rehabil       Date:  2021-08-18       Impact factor: 3.558