Resistor-free and one-board-fits-all ratio adjustable power splitter for add-on RF shimming in high field MRI.

Yue Zhu1, Ming Lu2, Xinqiang Yan3.   

Abstract

Ratio adjustable power splitter (RAPS) circuits were recently proposed for add-on RF shimming. Previous RAPSs split the input RF signal with a Wilkinson splitter or 50-Ω-terminated hybrid coupler into two branches, delay these two signals with cable/microstrip line phase shifters, and recombine them with another hybrid coupler. They require resistors to provide high output isolation and a cable/microstrip line library to realize desired splitting ratios. Here we propose a novel resistor-free RAPS circuit in which the Wilkinson splitter/50-Ω-terminated hybrid is replaced with a resistor-free T-junction splitter. A novel sliding mechanism was employed to further combine the T-junction's output arms with subsequent phase shifters and realize a one-board-fits-all design. The resistor-free RAPS was theoretically analyzed, simulated, and validated on workbench and MRI experiments. The resistor-free RAPS's splitting ratio has a tan/cot dependence on the phase/length difference between the T-junction output arms. The ratio can be continuously adjusted to any value by sliding the input arm without additional cable/microstrip libraries, largely saving time and effort when determining the best RF weights in practice. The fabricated resistor-free RAPS has a compact size, excellent input impedance matching, and a low insertion loss. Potential safety concerns caused by unwanted power dissipation on RF resistors are eliminated. The simulation and MRI experiments demonstrated that the resistor-free RAPS functions well on a widely-used Tx coil.
Copyright © 2022 Elsevier Inc. All rights reserved.

Entities:  

Keywords:  One-board-fits-all; Power splitter; RF shimming; Resistor-free; Ultrahigh field

Mesh:

Year:  2022        PMID: 35316747      PMCID: PMC9050946          DOI: 10.1016/j.jmr.2022.107194

Source DB:  PubMed          Journal:  J Magn Reson        ISSN: 1090-7807            Impact factor:   2.734


  34 in total

1.  Imaging brain function in humans at 7 Tesla.

Authors:  E Yacoub; A Shmuel; J Pfeuffer; P F Van De Moortele; G Adriany; P Andersen; J T Vaughan; H Merkle; K Ugurbil; X Hu
Journal:  Magn Reson Med       Date:  2001-04       Impact factor: 4.668

2.  DREAM--a novel approach for robust, ultrafast, multislice B₁ mapping.

Authors:  Kay Nehrke; Peter Börnert
Journal:  Magn Reson Med       Date:  2012-01-17       Impact factor: 4.668

3.  Transmit and receive transmission line arrays for 7 Tesla parallel imaging.

Authors:  Gregor Adriany; Pierre-Francois Van de Moortele; Florian Wiesinger; Steen Moeller; John P Strupp; Peter Andersen; Carl Snyder; Xiaoliang Zhang; Wei Chen; Klaas P Pruessmann; Peter Boesiger; Tommy Vaughan; Kāmil Uğurbil
Journal:  Magn Reson Med       Date:  2005-02       Impact factor: 4.668

4.  Exploring the limits of RF shimming for high-field MRI of the human head.

Authors:  Weihua Mao; Michael B Smith; Christopher M Collins
Journal:  Magn Reson Med       Date:  2006-10       Impact factor: 4.668

5.  BirdcageBuilder: Design of Specified-Geometry Birdcage Coils with Desired Current Pattern and Resonant Frequency.

Authors:  Chih-Liang Chin; Christopher M Collins; Shizhe Li; Bernard J Dardzinski; Michael B Smith
Journal:  Concepts Magn Reson       Date:  2002-06-28

6.  Array-compressed parallel transmit pulse design.

Authors:  Zhipeng Cao; Xinqiang Yan; William A Grissom
Journal:  Magn Reson Med       Date:  2015-10-28       Impact factor: 4.668

7.  Experimental implementation of array-compressed parallel transmission at 7 tesla.

Authors:  Xinqiang Yan; Zhipeng Cao; William A Grissom
Journal:  Magn Reson Med       Date:  2016-04-15       Impact factor: 4.668

8.  Multi-channel microstrip transceiver arrays using harmonics for high field MR imaging in humans.

Authors:  Bing Wu; Chunsheng Wang; Jonathan Lu; Yong Pang; Sarah J Nelson; Daniel B Vigneron; Xiaoliang Zhang
Journal:  IEEE Trans Med Imaging       Date:  2011-08-30       Impact factor: 10.048

9.  A 16-channel combined loop-dipole transceiver array for 7 Tesla body MRI.

Authors:  M Arcan Ertürk; Alexander J E Raaijmakers; Gregor Adriany; Kâmil Uğurbil; Gregory J Metzger
Journal:  Magn Reson Med       Date:  2016-02-17       Impact factor: 4.668

10.  Impact of number of channels on RF shimming at 3T.

Authors:  Alexander S Childs; Shaihan J Malik; Declan P O'Regan; Joseph V Hajnal
Journal:  MAGMA       Date:  2013-01-13       Impact factor: 2.310

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.