Literature DB >> 21878410

Multi-channel microstrip transceiver arrays using harmonics for high field MR imaging in humans.

Bing Wu1, Chunsheng Wang, Jonathan Lu, Yong Pang, Sarah J Nelson, Daniel B Vigneron, Xiaoliang Zhang.   

Abstract

Radio-frequency (RF) transceiver array design using primary and higher order harmonics for in vivo parallel magnetic resonance imaging imaging (MRI) and spectroscopic imaging is proposed. The improved electromagnetic decoupling performance, unique magnetic field distributions and high-frequency operation capabilities of higher-order harmonics of resonators would benefit transceiver arrays for parallel MRI, especially for ultrahigh field parallel MRI. To demonstrate this technique, microstrip transceiver arrays using first and second harmonic resonators were developed for human head parallel imaging at 7T. Phantom and human head images were acquired and evaluated using the GRAPPA reconstruction algorithm. The higher-order harmonic transceiver array design technique was also assessed numerically using FDTD simulation. Compared with regular primary-resonance transceiver designs, the proposed higher-order harmonic technique provided an improved g-factor and increased decoupling among resonant elements without using dedicated decoupling circuits, which would potentially lead to a better parallel imaging performance and ultimately faster and higher quality imaging. The proposed technique is particularly suitable for densely spaced transceiver array design where the increased mutual inductance among the elements becomes problematic. In addition, it also provides a simple approach to readily upgrade the channels of a conventional primary resonator microstrip array to a larger number for faster imaging.

Entities:  

Mesh:

Year:  2011        PMID: 21878410      PMCID: PMC3277810          DOI: 10.1109/TMI.2011.2166273

Source DB:  PubMed          Journal:  IEEE Trans Med Imaging        ISSN: 0278-0062            Impact factor:   10.048


  27 in total

1.  Planar strip array (PSA) for MRI.

Authors:  R F Lee; C R Westgate; R G Weiss; D C Newman; P A Bottomley
Journal:  Magn Reson Med       Date:  2001-04       Impact factor: 4.668

2.  Microstrip RF surface coil design for extremely high-field MRI and spectroscopy.

Authors:  X Zhang; K Ugurbil; W Chen
Journal:  Magn Reson Med       Date:  2001-09       Impact factor: 4.668

3.  Coupling and decoupling theory and its application to the MRI phased array.

Authors:  Ray F Lee; Randy O Giaquinto; Christopher J Hardy
Journal:  Magn Reson Med       Date:  2002-07       Impact factor: 4.668

4.  Design of a capacitively decoupled transmit/receive NMR phased array for high field microscopy at 14.1T.

Authors:  Xiaozhong Zhang; Andrew Webb
Journal:  J Magn Reson       Date:  2004-09       Impact factor: 2.229

5.  Transmit and receive transmission line arrays for 7 Tesla parallel imaging.

Authors:  Gregor Adriany; Pierre-Francois Van de Moortele; Florian Wiesinger; Steen Moeller; John P Strupp; Peter Andersen; Carl Snyder; Xiaoliang Zhang; Wei Chen; Klaas P Pruessmann; Peter Boesiger; Tommy Vaughan; Kāmil Uğurbil
Journal:  Magn Reson Med       Date:  2005-02       Impact factor: 4.668

6.  Tailored utilization of acquired k-space points for GRAPPA reconstruction.

Authors:  Peng Qu; Gary X Shen; Chunsheng Wang; Bing Wu; Jing Yuan
Journal:  J Magn Reson       Date:  2005-05       Impact factor: 2.229

7.  Manipulation of image intensity distribution at 7.0 T: passive RF shimming and focusing with dielectric materials.

Authors:  Qing X Yang; Weihua Mao; Jinghua Wang; Michael B Smith; Hao Lei; Xiaoliang Zhang; Kamil Ugurbil; Wei Chen
Journal:  J Magn Reson Imaging       Date:  2006-07       Impact factor: 4.813

8.  Adaptive SENSE reconstruction for parallel imaging with massive array coils.

Authors:  Jong Bum Son; Jim X Ji; Mary P McDougall; Steve M Wright
Journal:  Conf Proc IEEE Eng Med Biol Soc       Date:  2004

9.  9.4T human MRI: preliminary results.

Authors:  Thomas Vaughan; Lance DelaBarre; Carl Snyder; Jinfeng Tian; Can Akgun; Devashish Shrivastava; Wanzahn Liu; Chris Olson; Gregor Adriany; John Strupp; Peter Andersen; Anand Gopinath; Pierre-Francois van de Moortele; Michael Garwood; Kamil Ugurbil
Journal:  Magn Reson Med       Date:  2006-12       Impact factor: 4.668

10.  Designing multichannel, multidimensional, arbitrary flip angle RF pulses using an optimal control approach.

Authors:  Dan Xu; Kevin F King; Yudong Zhu; Graeme C McKinnon; Zhi-Pei Liang
Journal:  Magn Reson Med       Date:  2008-03       Impact factor: 4.668

View more
  21 in total

1.  Image homogenization using pre-emphasis method for high field MRI.

Authors:  Ye Li; Chunsheng Wang; Baiying Yu; Daniel Vigneron; Wei Chen; Xiaoliang Zhang
Journal:  Quant Imaging Med Surg       Date:  2013-08

2.  Design and Test of Magnetic Wall Decoupling for Dipole Transmit/Receive Array for MR Imaging at the Ultrahigh Field of 7T.

Authors:  Xinqiang Yan; Xiaoliang Zhang; Long Wei; Rong Xue
Journal:  Appl Magn Reson       Date:  2014-11-27       Impact factor: 0.831

3.  Sensitivity enhancement of traveling wave MRI using free local resonators: an experimental demonstration.

Authors:  Xiaoliang Zhang
Journal:  Quant Imaging Med Surg       Date:  2017-04

4.  Hepatic fat assessment using advanced Magnetic Resonance Imaging.

Authors:  Yong Pang; Baiying Yu; Xiaoliang Zhang
Journal:  Quant Imaging Med Surg       Date:  2012-09

5.  Quadrature transmit array design using single-feed circularly polarized patch antenna for parallel transmission in MR imaging.

Authors:  Yong Pang; Baiying Yu; Daniel B Vigneron; Xiaoliang Zhang
Journal:  Quant Imaging Med Surg       Date:  2014-02

6.  Design and numerical evaluation of a volume coil array for parallel MR imaging at ultrahigh fields.

Authors:  Yong Pang; Ernest W H Wong; Baiying Yu; Xiaoliang Zhang
Journal:  Quant Imaging Med Surg       Date:  2014-02

7.  Parallel imaging performance investigation of an 8-channel common-mode differential-mode (CMDM) planar array for 7T MRI.

Authors:  Xiaoqing Hu; Xiao Chen; Xin Liu; Hairong Zheng; Ye Li; Xiaoliang Zhang
Journal:  Quant Imaging Med Surg       Date:  2014-02

8.  Magnetic wall decoupling method for monopole coil array in ultrahigh field MRI: a feasibility test.

Authors:  Xinqiang Yan; Xiaoliang Zhang; Long Wei; Rong Xue
Journal:  Quant Imaging Med Surg       Date:  2014-04

9.  Precompensation for mutual coupling between array elements in parallel excitation.

Authors:  Yong Pang; Xiaoliang Zhang
Journal:  Quant Imaging Med Surg       Date:  2011-12

10.  Optimizing the ICE decoupling element distance to improve monopole antenna arrays for 7 Tesla MRI.

Authors:  Xinqiang Yan; Xiaoliang Zhang; Rong Xue; John C Gore; William A Grissom
Journal:  Magn Reson Imaging       Date:  2016-07-25       Impact factor: 2.546

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.