Literature DB >> 23316109

BirdcageBuilder: Design of Specified-Geometry Birdcage Coils with Desired Current Pattern and Resonant Frequency.

Chih-Liang Chin1, Christopher M Collins, Shizhe Li, Bernard J Dardzinski, Michael B Smith.   

Abstract

A simple method for birdcage coil design (high pass, low pass, and band pass) is presented. Rather than iteratively approaching the Larmor resonant frequency with known capacitances and calculated inductances, a more versatile approach to birdcage coil design is developed and validated, in which the necessary capacitances are calculated using a desired current pattern, a calculated inductance, and a predetermined resonant frequency. In order to expedite coil design for experienced and novice coil builders, a computer program (BirdcageBuilder) is also implemented based on this method. Experimental results show that the calculated capacitances and actual capacitances for several existing birdcage coils are in good agreement.

Year:  2002        PMID: 23316109      PMCID: PMC3541780          DOI: 10.1002/cmr.10030

Source DB:  PubMed          Journal:  Concepts Magn Reson        ISSN: 1043-7347


  6 in total

1.  Practical aspects of birdcage coils.

Authors:  F D Doty; G Entzminger; C D Hauck; J P Staab
Journal:  J Magn Reson       Date:  1999-05       Impact factor: 2.229

2.  Experimental design and fabrication of birdcage resonators for magnetic resonance imaging.

Authors:  T Vullo; R T Zipagan; R Pascone; J P Whalen; P T Cahill
Journal:  Magn Reson Med       Date:  1992-04       Impact factor: 4.668

3.  A technique for double resonant operation of birdcage imaging coils.

Authors:  P M Joseph; D Lu
Journal:  IEEE Trans Med Imaging       Date:  1989       Impact factor: 10.048

4.  Generalized electrical analysis of low-pass and high-pass birdcage resonators.

Authors:  R J Pascone; B J Garcia; T M Fitzgerald; T Vullo; R Zipagan; P T Cahill
Journal:  Magn Reson Imaging       Date:  1991       Impact factor: 2.546

5.  A method to create an optimum current distribution and homogeneous B1 field for elliptical birdcage coils.

Authors:  S Li; C M Collins; B J Dardzinski; C L Chin; M B Smith
Journal:  Magn Reson Med       Date:  1997-04       Impact factor: 4.668

6.  A simple method to incorporate the effects of an RF shield into RF resonator analysis for MRI applications.

Authors:  J Jin; R L Magin; G Shen; T Perkins
Journal:  IEEE Trans Biomed Eng       Date:  1995-08       Impact factor: 4.538

  6 in total
  9 in total

1.  A degeneracy study in the circulant and bordered-circulant approach to birdcage and planar coils.

Authors:  Y-C N Cheng; T P Eagan; T Chmielewski; J Flock; M-C Kang; T K Kidane; Sh M Shvartsman; R W Brown
Journal:  MAGMA       Date:  2003-08-07       Impact factor: 2.310

2.  An efficient design for birdcage probes dedicated to small-animal imaging experiments.

Authors:  M Lupu; J L Dimicoli; A Volk; J Mispelter
Journal:  MAGMA       Date:  2004-11-08       Impact factor: 2.310

3.  A volume birdcage coil with an adjustable sliding tuner ring for neuroimaging in high field vertical magnets: ex and in vivo applications at 21.1T.

Authors:  Chunqi Qian; Ihssan S Masad; Jens T Rosenberg; Malathy Elumalai; William W Brey; Samuel C Grant; Peter L Gor'kov
Journal:  J Magn Reson       Date:  2012-05-30       Impact factor: 2.229

4.  Tailored birdcage resonator for magnetic resonance imaging at 7 T using 3D printing.

Authors:  Philip Kemper; Jorg Thöming; Ekkehard Küstermann
Journal:  HardwareX       Date:  2022-06-09

5.  Resistor-free and one-board-fits-all ratio adjustable power splitter for add-on RF shimming in high field MRI.

Authors:  Yue Zhu; Ming Lu; Xinqiang Yan
Journal:  J Magn Reson       Date:  2022-03-15       Impact factor: 2.734

6.  Visualizing brain inflammation with a shingled-leg radio-frequency head probe for 19F/1H MRI.

Authors:  Helmar Waiczies; Stefano Lepore; Susanne Drechsler; Fatimunnisa Qadri; Bettina Purfürst; Karl Sydow; Margitta Dathe; André Kühne; Tomasz Lindel; Werner Hoffmann; Andreas Pohlmann; Thoralf Niendorf; Sonia Waiczies
Journal:  Sci Rep       Date:  2013       Impact factor: 4.379

7.  Optimization of a quadrature birdcage coil for functional imaging of squirrel monkey brain at 9.4T.

Authors:  Ming Lu; Zhangyan Yang; Feng Wang; Gary Drake; Li Min Chen; John C Gore; Xinqiang Yan
Journal:  Magn Reson Imaging       Date:  2021-03-17       Impact factor: 3.130

8.  Optimized (31)P MRS in the human brain at 7 T with a dedicated RF coil setup.

Authors:  Bart L van de Bank; Stephan Orzada; Frits Smits; Miriam W Lagemaat; Christopher T Rodgers; Andreas K Bitz; Tom W J Scheenen
Journal:  NMR Biomed       Date:  2015-10-07       Impact factor: 4.044

9.  Design and construction of an optimized transmit/receive hybrid birdcage resonator to improve full body images of medium-sized animals in 7T scanner.

Authors:  Nibardo Lopez Rios; Philippe Pouliot; Konstantinos Papoutsis; Alexandru Foias; Nikola Stikov; Frédéric Lesage; Mathieu Dehaes; Julien Cohen-Adad
Journal:  PLoS One       Date:  2018-02-01       Impact factor: 3.240

  9 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.